Product Description
The Digital Display Pressure Steam Vertical Autoclave models YR05676 to YR05681 represent a leap forward in laboratory sterilization technology, featuring a sleek design and robust specifications. These vertical steam autoclaves operate under a working pressure of 0.22 Mpa and reach a working temperature of 134°C, maintaining an impressive temperature accuracy of 0.1℃. With a temperature range between 105℃ and 134℃, they provide flexibility to accommodate various sterilization needs. A built-in stainless steel 304 steam generator and microprocessor control ensure efficient and precise steam production and operation. The models also feature a digital display for easy monitoring.
Each unit varies in chamber volume from 35L to 150L, allowing users to select the model that best fits their capacity requirements. The autoclave’s form is crafted from fully stainless steel 304, ensuring durability and longevity, while the two stainless steel baskets provide ample space for loading instruments. The autoclaves operate at a voltage of 110-220V and are suited for diverse operational environments. Available in English for broader accessibility, these autoclaves are designed with the end-user in mind.
Technical Specifications
| Model | YR05676 | YR05677 | YR05678 | YR05679 | YR05680 | YR05681 |
| Working pressure | 0.22 Mpa | |||||
| Working temperature | 134°C | |||||
| Working temperature range | 105 – 134℃ | |||||
| Sterilization time | 0-99 hour 59 min | |||||
| Temperature accuracy | 0.1℃ | |||||
| Heat average | ≤1°C | |||||
| Type | Steam Vertical Autoclave | |||||
| Control | Microprocessor | |||||
| Display | Digital display | |||||
| Steam generator | Built-in steam generator, stainless steel 304 | |||||
| Material | Fully stainless steel 304 | |||||
| Loading | 2 pcs stainless steel baskets | |||||
| Language | English | |||||
| Voltage | 110-220V. 50/60Hz | |||||
| Chamber Volume | 35L / Ø318×
450mm |
50L / Ø340×
550mm |
75L / Ø400×
600mm |
100L / Ø440×
650mm |
120L / Ø480×660mm | 150L / Ø510×740mm |
| Product Size | 450×450×
1010mm |
510×470×
1130mm |
560×560×
1130mm |
540×560×
1250mm |
600×640×1250mm | 670×690×
1330mm |
| Package Size | 570×570×
1150mm |
590×590×
1280mm |
650×650×
1280mm |
680×680×
1370mm |
730×730×
1370mm |
760×760×
1370mm |
| G.W. /N.W. | 72/56kg | 88/68kg | 100/80kg | 110/85kg | 125/100kg | 140/110kg |
| Power | 2.5kw | 3.0kw | 4.5kw | 4.5kw | 6.0kw | 6.0kw |
Market Price
The market price for the Digital Display Pressure Steam Vertical Autoclave varies greatly based on the model and additional features a customer may choose. Generally, prices range from several hundred to a few thousand dollars. On average, smaller units like the YR05676 may be more economical due to their lower capacity and power requirements, while larger units such as the YR05681, with 150L chamber volume, command higher prices. It’s important to request a quote specifically tailored to your needs at Kalstein, ensuring you get the most competitive pricing available.
Frequently Asked Questions
What is the main function of the Digital Display Pressure Steam Vertical Autoclave?
This autoclave is primarily used for sterilizing laboratory instruments and materials, ensuring they are free from microbial life.
What kind of materials can be sterilized in this autoclave?
The autoclave can sterilize various materials commonly found in laboratories, including glassware, instruments, and some plastic components that can withstand the sterilization temperatures.
How often should the autoclave be serviced?
Regular maintenance and inspection, recommended every six months, can help ensure optimal performance and longevity of the equipment.
Advantages and Disadvantages
Advantages: The Digital Display Pressure Steam Vertical Autoclave offers precise temperature control and flexibility with its wide range of working temperatures. The use of stainless steel 304 ensures high durability and resistance to corrosion. Additionally, the digital display and built-in steam generator streamline the operation process, making it user-friendly and efficient.
Disadvantages: One potential downside is the initial cost, which can be high depending on the model and features. Another consideration is the requirement for a consistent power source, which can be a limitation in areas with power instability.
Field Use of the Product
In practical scenarios, these autoclaves are indispensable in laboratories for sterilizing various instruments and materials. Their use extends across different sectors such as pharmaceuticals, research institutions, and clinical laboratories. The reliability and efficiency of these autoclaves enable fast turnaround times, even in high-demand environments, ensuring that the sterilization process does not impede lab productivity.
Technicians appreciate the straightforward operation facilitated by the digital display and automated control systems, reducing the likelihood of user error and enhancing overall safety in the lab.
Recommendations
To optimize the use of the Digital Display Pressure Steam Vertical Autoclave, regularly clean the chamber and baskets to prevent buildup of residues. Maintain a log for each sterilization cycle to monitor performance over time and detect any deviations from expected outcomes. Additionally, consider implementing a scheduled maintenance plan to extend the equipment’s lifespan and ensure its safety and efficiency.
Should you require more information or a customized quote, consider visiting our Kalstein Plus platform, where you can effortlessly request a quotation suited to your specific laboratory needs.
If you’re looking for a fusion of innovation and quality, you’ve come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the friendliest prices. Don’t hesitate any longer, we bring science to life, it’s time to join our community. https://kalstein.net/en/product/digital-display-pressure-steam-vertical-autoclave-yr05676-yr05681/.