LED Double-Head Surgical Lamp without YR06115

The LED Dual-head Shadowless Surgery Light YR06115 is a state-of-the-art illumination tool designed to enhance visibility during complex surgical procedures. This advanced surgical light is equipped with a whole reflection optical system developed using CAD/CAM technology, ensuring an impressive illumination depth of up to 1300mm. With color temperature compensation technology, it offers enhanced color reversion, making it particularly suitable for intricate surgeries like encephalon and thorax operations. Featuring a German-made PC panel (anti-bullet plastic) and an imported balance arm suspension system, the lamp offers smooth and stable positioning, adapting to various heights and angles with its 360-degree universal design.
This page provides an overview of the LED Double-Head Surgical Lamp without Shadows YR06115, including selection criteria, investment factors, operational advantages and maintenance recommendations. The aim is to support an informed decision before requesting a quotation.
This Kalstein model is available for laboratories across Latin America, Europe, Africa, the Middle East and Asia, with selection criteria adapted to the diversity of local purchasing, installation and support conditions in each region.
Key factors to consider

Before selecting the LED Double-Head Surgical Lamp without Shadows YR06115, confirm workflow, available space, required accessories and installation conditions. This prevents oversizing the purchase and helps prepare a more accurate quotation.
The LED Dual-head Shadowless Surgery Light YR06115 is used in various surgical settings, providing superior lighting that reduces shadows and enhances visibility in complex procedures. Its design allows surgeons to focus on the task at hand without distractions from inadequate lighting or unwanted shadows.
Across these markets, evaluation should consider varied local contexts such as international laboratory procurement spanning Latin America, Europe, Africa, the Middle East and Asia and match the product to the real workload of the laboratory in each country.
Market price range

The investment should be evaluated according to configuration, required accessories, installation conditions and available technical support.
The final price may vary according to configuration, accessories, logistics, warranty and territorial availability. Compare the technical sheet with the real laboratory workload before confirming the investment.
Budget comparison varies by country and should include the regulatory requirements specific to each market, the electrical conditions of each region, accessories, logistics and after-sales support.
Value for money

Advantages: High illumination depth, excellent color temperature compensation, durable design with long LED lifespan, flexible and stable positioning. Disadvantages: Higher initial investment cost compared to basic models, may require professional installation in specialized settings.
Value for money should be reviewed together with equipment stability, after-sales support, technical documentation and expected service life. A well-matched selection reduces downtime and improves return on investment.
Advantages and disadvantages

The LED Dual-head Shadowless Surgery Light YR06115 is used in various surgical settings, providing superior lighting that reduces shadows and enhances visibility in complex procedures. Its design allows surgeons to focus on the task at hand without distractions from inadequate lighting or unwanted shadows.
Main advantages include specialized application, integration with laboratory routines and accessory configuration. Limitations may include installation requirements, user training and preventive maintenance to preserve performance.
Expected lifespan based on use and maintenance

For optimal performance, it is recommended to conduct regular maintenance checks and follow the manufacturer's guidelines for installation and use. Additionally, consider using Kalstein Plus for a seamless purchasing experience and to request an automatic quote tailored to your specific requirements.
Service life depends on usage frequency, cleaning, storage, calibration when applicable and adherence to technical recommendations. A structured maintenance plan helps preserve accuracy, safety and operational continuity.
A support and spare-parts network deployed across Latin America, Europe, Africa, the Middle East and Asia helps preserve service continuity and plan preventive maintenance without extended downtime.
Specifications table for the LED Double-Head Surgical Lamp without YR06115

LED Double-Head Surgical Lamp without YR06115
| Model | YR06115 |
| Illuminance | ≥160,000Lux / ≥120,000Lux |
| Color temperature | 3800±500K, 4400±500K, 5000±500K |
| Color reduction index (Ra) | 95 |
| Illuminance depth | ≥1300mm |
| Total irradiance | 450W/m² / 390W/m² |
| Size of light field | 160~280mm |
| LED bulb | 3.3mW/m² lx |
| Service life of illuminant | 50,000h |
| Power supply voltage | AC 110-240V, 50/60Hz |
| Brightness adjustment | Automatic 8-stage continuous light adjustment |
| Lowest height of installation | 2900mm |
| Total power consumption | 140W |
| Total LED bulb quantity | 180 pcs |
Products related to model YR06115

Veterinary Digital Slit Lamp YR06200
Ver producto
Veterinary Handheld Slit Lamp (2-Magnification) YR06199
Ver producto
Ultraviolet Sterilization Lamp YR06190
Ver producto
Veterinary Woods Lamp YR06189
Ver producto
Cable-free Head Light YR06123
Ver producto
Cable-free Head Light YR06122
Ver producto
Light Single Arm Revolving Pendant YR06121
Ver producto
Standing LED Surgery Light YR06120
Ver productoFrequently Asked Questions about the LED Double-Head Surgical Lamp without YR06115
Q: What is the lifespan of the LED bulbs in the YR06115?
A: The LED bulbs have a lifespan of approximately 50,000 hours, providing long-term usage and reducing the need for frequent replacements.
Q: Can the brightness be adjusted?
A: Yes, the YR06115 features an automatic 8-stage continuous light adjustment for optimal illumination control.
How do I choose the right LED Double-Head Surgical Lamp without YR06115 for my laboratory?
Selection should start from workload, critical technical parameters, available space and frequency of use. Kalstein can support the comparison between operational needs, budget and maintenance requirements to avoid choosing equipment that is oversized or insufficient.
What should I review before requesting a quotation?
Review the model, technical specifications, required accessories, electrical conditions, consumables, delivery timing and installation needs. With this information, the quotation can be prepared more accurately and aligned with the laboratory workflow.
Does Kalstein provide guidance for this type of equipment?
Yes. The commercial and technical team can support product evaluation, explain differences between models, answer application questions and advise on preventive maintenance, spare parts and documentation required for a secure purchase.
What maintenance helps extend the equipment lifespan?
Follow the manufacturer manual, perform regular cleaning, verify calibrations or controls when applicable, avoid workload abuse and keep maintenance records. Stable use and preventive routines reduce failures and improve operational continuity.