Metallurgical Microscope YR0251 - YR0252 is a sophisticated tool designed for high-precision microscopic analysis, essential in metallurgy and material sciences. Featuring a Seidentopf trinocular head inclined at 30°, with interpupillary distance ranging from 48 to 75mm, this microscope ensures comfortable usage during extended observation sessions. Equipped with infinity plan achromatic objectives and extra wide field eyepieces, users benefit from enhanced optical clarity. The microscope has both bright and dark field capabilities, making it versatile for a broad range of applications.
This page provides an overview of the Microscope Trinocular YR0252, including selection criteria, investment factors, operational advantages and maintenance recommendations. The aim is to support an informed decision before requesting a quotation.
This Kalstein model is available for laboratories across Latin America, Europe, Africa, the Middle East and Asia, with selection criteria adapted to the diversity of local purchasing, installation and support conditions in each region.
Key factors to consider

Before selecting the Microscope Trinocular YR0252, confirm workflow, available space, required accessories and installation conditions. This prevents oversizing the purchase and helps prepare a more accurate quotation.
Its use is oriented to laboratory routines that require observation, control and operational continuity.
Across these markets, evaluation should consider varied local contexts such as international laboratory procurement spanning Latin America, Europe, Africa, the Middle East and Asia and match the product to the real workload of the laboratory in each country.
Market price range

The investment should be evaluated according to configuration, required accessories, installation conditions and available technical support.
The final price may vary according to configuration, accessories, logistics, warranty and territorial availability. Compare the technical sheet with the real laboratory workload before confirming the investment.
Budget comparison varies by country and should include the regulatory requirements specific to each market, the electrical conditions of each region, accessories, logistics and after-sales support.
Value for money

Advantages: The microscope offers exceptional optical performance with infinity plan achromatic objectives, a variety of illumination options including halogen and Kohler, and user-friendly features like the bright/dark field toggle and tension adjustment. Disadvantages: Its advanced features come with a higher price point, making it more suitable for institutions or labs with a significant need for top-tier microscopy capabilities.
Value for money should be reviewed together with equipment stability, after-sales support, technical documentation and expected service life. A well-matched selection reduces downtime and improves return on investment.
Advantages and disadvantages

Its use is oriented to laboratory routines that require observation, control and operational continuity.
Main advantages include specialized application, integration with laboratory routines and accessory configuration. Limitations may include installation requirements, user training and preventive maintenance to preserve performance.
Expected lifespan based on use and maintenance

To maintain optimal performance, regular cleaning of the lenses with appropriate solutions is recommended. While not in use, cover the microscope to prevent dust accumulation. Make sure to perform periodic calibrations to ensure precise measurements and observations. For long-lasting bulb life, adjust brightness levels appropriately during operation.
Service life depends on usage frequency, cleaning, storage, calibration when applicable and adherence to technical recommendations. A structured maintenance plan helps preserve accuracy, safety and operational continuity.
A support and spare-parts network deployed across Latin America, Europe, Africa, the Middle East and Asia helps preserve service continuity and plan preventive maintenance without extended downtime.
Specifications table for the Microscope Trinocular YR0252

Microscope Trinocular YR0252
- Cabezal trinocular Scidentopf 30° Inclinado, Interpupilar 48~75mm
- Ocular de campo extra ancho EW10x/22 mm, tubo ocular de 30 mm de diámetro
- Perilla de interruptor de campo claro/campo oscuro
- Condensador oscilante NA0.95/0.25
- Perilla de ajuste fino y grueso coaxial
- Iluminación externa, colector asperical
- Lámpara halógena 6V30W
- Perilla e interruptor de ajuste de brillo
Especificaciones Técnicas
| Model | YR0251 | YR0252 (current) | |
| Optical system | Infinite optical system, bright field/dark field, polarization | ||
| Head | 30° inclined trinocular Seidentopf head, interpupillary 48-75 mm | ||
| Eyepiece | Extra wide field eyepiece EW10x/22 mm, 30 mm diameter eyepiece tube | ||
| Revolving nosepiece | Five-position backward revolving nosepiece | ||
| Objective | Infinity Plan achromatic objectives 5x/ 0.12/ ∞/ – (BF) | ||
| Infinity Plan achromatic objectives 10x/ 0.25/ ∞/ – (BF/DF) | |||
| Infinity Plan achromatic objectives 20x/ 0.4/ ∞/0 (BF/DF) | |||
| Infinity Plan achromatic objectives 50x/ 0.75/ ∞/0 (BF) | |||
| Infinity Plan achromatic objectives 100x/0.90/∞/0 (BF) | |||
| Infinity Plan achromatic objectives 40x/0.65/∞/0.17 | or | ||
| Infinity Plan achromatic objectives 100x/1.25/∞/0.17 | or | ||
| Focusing | Coaxial coarse and fine adjustment, fine focus precision <1 um, with safety stop, with tension adjustment | ||
| Stage | Maximum sample height 30 mm | ||
| Double-layer mechanical stage 186*138 mm, movement range 74*50 mm, includes: | |||
| –Sample preparation plate | |||
| –Slide glass | or | ||
| Reflecting illumination | 24 V 100 W halogen light, adjustable brightness | ||
| Kohler illumination with aspheric condenser | |||
| Polarizer and analyzer, integrated plate for polarizer and analyzer | |||
| Blue, Green, Yellow Filter, Gound Glass | |||
| Transmitting illumination | Swinging condenser NA0.9/0.25 | or | |
| 24V 100W Halogen Light With Aspheric Condenser | |||
| Blue filter | |||
| Accessories | YR0251 | YR0252 | |
| Objective | Infinity Plan achromatic objectives 40x/0.6/∞/0 (BF/DF) | YR0252-op1 | |
| Infinity Plan achromatic objectives 50x/0.75/∞/0 (BF/DF) | YR0252-op2 | ||
| Polarizer | polarizer and analyzer, integrated plate for polarizer and analyzer | | YR0252-op3 | |
| For reflecting illumination | |||
| Filter | Neutral filter ND25 | YR0252-op4 | |
| Neutral filter ND6 | YR0252-op5 | ||
| Adapter | Photo adapter, for Nikon or Canon SLR camera | YR0252-op6 | |
| C mount 1.0x | YR0252-op7 | ||
| C mount 0.5x | YR0252-op8 | ||
| Other | Sample holder | ||
Products related to model YR0252

Multi Viewing Research Laboratory Microscope YR06688
Ver producto
Biological Microscope YR06685
Ver producto
Laboratory Microscope YR06686
Ver producto
LCD Digital Biologcal Microscope YR06684
Ver producto
Laboratory Biological Microscope YR06683
Ver producto
Inverted Biological Phase Contrast Microscope YR06682
Ver producto
Motorized Forensic Comparison Microscope YR06681
Ver producto
Biological Binocular Microscope YR06614
Ver productoFrequently Asked Questions about the Microscope Trinocular YR0252
What are the compatibility options for cameras?
The microscope supports photo adapters for Nikon and Canon SLR cameras, allowing seamless integration for documentation purposes.
Can this microscope handle polarized light analyses?
Yes, it includes a polarizer and analyzer for comprehensive polarizing capabilities.
What is the maximum sample height it can handle?
The microscope can accommodate specimens up to 30mm in height, which is standard for various metallurgical samples.
How do I choose the right microscope trinocular yr0252 for my laboratory?
Selection should start from workload, critical technical parameters, available space and frequency of use. Kalstein can support the comparison between operational needs, budget and maintenance requirements to avoid choosing equipment that is oversized or insufficient.
What should I review before requesting a quotation?
Review the model, technical specifications, required accessories, electrical conditions, consumables, delivery timing and installation needs. With this information, the quotation can be prepared more accurately and aligned with the laboratory workflow.
Does Kalstein provide guidance for this type of equipment?
Yes. The commercial and technical team can support product evaluation, explain differences between models, answer application questions and advise on preventive maintenance, spare parts and documentation required for a secure purchase.
What maintenance helps extend the equipment lifespan?
Follow the manufacturer manual, perform regular cleaning, verify calibrations or controls when applicable, avoid workload abuse and keep maintenance records. Stable use and preventive routines reduce failures and improve operational continuity.