Description
-86°C dual system ultra low temperature freezer
Feature
- Two independent refrigeration systems are used, one of which can maintain a temperature of -70 in one set.
- Dual system can work at the same time to achieve rapid cooling, and the cooling time is shortened by more than 50%.
- Touch screen, temperature curve, alarm information record and query, user management mode, self-diagnosis
- Two independent refrigeration systems are used, one of which can maintain the temperature of the cabinet at -80 °C when the fault occurs.
- Standard test hole, USB interface and remote alarm interface
- High temperature and low temperature alarm in the box, sound and light alarm, optional SMS notification and other alarm methods
- Increased cooling rate by 20% and uniformity by 30%
- A refrigeration circuit that doubles the system components compared to a conventional two-stage cascade system
- Double-machine cascade refrigeration system using fluorine-free environmentally friendly alkane refrigerant, energy saving 50%
- VIPIIPLUS second generation vacuum insulation board technology, the refrigerator has good insulation performance, designed for entering the elevator
- Product structure optimized for biological sample libraries, providing storage space of up to 40,000 samples
- When power is restored, the simultaneous start of all equipment will cause a large impact on the power grid, which may cause the circuit breaker to trip; the specially designed equipment delay start function for this case may make the equipment
- The inner door is detachable for easy defrosting and cleaning of customers;
Technical Specifications
Model | YR05304 | |
Specificaitons | Shelf/drawer QTY | Stainless steel shelf/3 |
Cooling | Direct cooling | |
Defrost | Manual | |
Refrigerant | Mixed-gas | |
Power Consumption( kWh/24h) | ||
Noise (db) | 53 | |
Ambient temperature (℃) | 10~32℃ | |
Temperature range (℃) | -40~-86℃ | |
Cooling system | Compressor brand/QTY | SECOP/2 |
Sensor | PTC | |
Temperature controller | Microprocessor | |
Display | LCD display | |
Power | Voltage/frequency (V/Hz) | 220/50Hz |
Power (W) | ||
Current (A) | ||
Material | Inside material | Stainless steel |
Outside material | Color sprayed steel | |
Insulation | PURF | |
Size | Capacity(L/cu.ft) | 728 |
NT./GT.(kg) | 360/401.5 | |
Exterior size(W*D*H)(mm) | 1260*890*2010 | |
Interior size(W*D*H)(mm) | 963*558*1350 | |
Package size(W*D*H)(mm) | 1320*970*2190 | |
CBM | 2.8 | |
20GP/40GP/40HQ | 2.80 | |
Frozen Racks | Racks | 8/18/18 |
Boxes (2 Inches) | 504 | |
Samples(2ml) | 50400 | |
Alarm | High/low temperature | Y |
Power failure | Y | |
Abnormal voltage | Y | |
Sensor error | Y | |
Filter screen check | Y | |
Thermostat failure | Y | |
Low battery | Y | |
Condenser clean | Y | |
High ambient temperature | Y | |
Door ajar | Y | |
Power failure backup system(alarm) | 73h | |
Accessories | Castor | Y |
Inside door | 2 | |
Test hole QTY/diameter | 1/25MM | |
USB port | Y | |
Chart recorder | / | |
Data logger | Optional | |
Remote alarm port | Y | |
Optional | CO2 back up system | Optional |
LN2 back up system | Optional | |
Other | Certification | ISO.CE |