Automatic Vertical Sliding Door Rapid Cooling Culture Medium Sterilizer YR05758-1

Automatic Vertical Sliding Door Rapid Cooling Culture Medium Sterilizer YR05758-1 — equipo de laboratorio Kalstein con especificaciones técnicas, características avanzadas y soluciones profesionales certificadas para uso científico.
Market Price
The YR05758-1 Rapid Cooling Vertical Sliding Door Automatic Sterilizer costs between $31,000 and $40,000 USD, depending on specifications and additional features. This price reflects its advanced technology and superior functionality. It is a valuable investment for institutions requiring high-level sterilization. To get a personalized quote tailored to your needs, use the Kalstein Plus platform. This platform streamlines the request and automatic quotation process.Frequently Asked Questions
- What is the capacity of the sterilizer chamber? The chamber capacity is 250 liters. Its dimensions are 550 mm in width, 550 mm in height, and 850 mm in depth.
- What materials are used in the construction of the sterilizer? High-quality materials are used: AISI 316L for the inner chamber and door, AISI 304 for the jacket, and AISI 316L for the built-in steam generator.
- Is it easy to operate? Yes, it is user-friendly. The imported Siemens PLC programmable controller and color touch screen allow automatic control of the entire process and real-time display of sterilization parameters.
Advantages and Disadvantages
The YR05758-1 sterilizer offers many advantages. Its robust stainless steel construction ensures durability. The precise temperature and pressure control, and space-saving vertical sliding door system, enhance functionality. The high-quality pneumatic sealing ring provides better sealing performance and a longer lifespan. However, its weight of 750 kg can pose challenges in mobility and installation.Product Use in the Field
This sterilizer is widely used in settings requiring efficient and safe sterilization. In the pharmaceutical and research industries, it sterilizes culture media, syringes, and other critical instruments. Its rapid cooling capacity and advanced control system make it perfect for applications demanding high precision and reliability.Recommendations
To maximize the performance of the YR05758-1 sterilizer, follow the manufacturer’s maintenance recommendations. Regularly clean the sterilization chamber, check safety systems, and perform functionality tests before each cycle. Ensure the water level and the condition of the pneumatic sealing ring are optimal. If you want to purchase this sterilizer and need more information about its price and specifications, request a quote or generate an automatic quote through the Kalstein Plus platform. This tool provides the necessary information quickly and efficiently. It ensures you get the ideal equipment to meet your specific sterilization needs. Enhance your process efficiency with this high-quality, reliable sterilizer.Features
- Vertical sliding door opening and closing structure, motor chain drives the door up and down vertical lift sliding open and close, without manual operation, saving space occupation.
- Dual door passage type, dual door interlocking, with pressure safety interlocking, liquid program with temperature door safety interlocking.
- Pneumatic pressure-driven sealing ring for automatic sealing, a new high-quality high tear resistant silicone rubber circular door sealing ring, a specially coated surface, wear-resistant and smooth, with better sealing effect and longer service life, up to 2000 cycles.
- The main structure is rectangular section, European ring reinforcement jacket without flange structure. The sealing groove is welded directly on the ring jacket at both ends.
- The material of the inner chamber and door are made of AISI 316L, the jacket material is AISI 304, and the built-in steam generator material is AISI 316L. The inner surface of the chamber, door and evaporator is mechanically polished and electrolytically polished, and the surface roughness is less than or equal to 0.4.
- Control system: Imported Siemens programmable controller PLC and color touch screen, the whole process automatic program control, automatic display running process status, temperature, pressure, F0 value, time and other parameters.
Technical Specifications
| Model | YR05758-1 |
| Chamber Size (W*H*D) | 250L 550*550*850mm |
| Overall dimensions (L*W*H) | 1290*1200*1850mm |
| Weight (kg) | 750 |
| Steam consumption (kg/cycle) | 16 |
| Water consumption (kg/cycle) | 120 |
| Power | 22 kw |
| Generator design pressure | 1.0 MPa |
| Sterilization temperature control accuracy | ±0.2℃ |
| Design temperature | 150℃ |
| Temperature uniformity | ±0.5℃ |
| Max. operating temperature | 139℃ |
| Max. operating temperature | 139℃ |
| Chamber relief valve | 0.28MPa |
| Maximum operating pressure | 0.25MPa |
| Jacket relief valve | 0.28 MPa |
Technical specifications
| Dimensions | L 142 × W 135 × H 205 cm |
|---|---|
| Weight | 930 kg |
| Manufacturer | Kalstein |
Video Automatic Vertical Sliding Door Rapid Cooling Culture Medium Sterilizer YR05758-1
Frequently asked questions
How to know the prices of Automatic Vertical Sliding Door Rapid Cooling Culture Medium Sterilizer YR05758-1?
To know the price of Automatic Vertical Sliding Door Rapid Cooling Culture Medium Sterilizer YR05758-1, please send us an email with your request through the contact form AQUI.
What are the delivery times for Automatic Vertical Sliding Door Rapid Cooling Culture Medium Sterilizer YR05758-1?
Delivery time depends on stock availability and freight type (air or sea). In stock: air 15-30 days, sea 45-60 days. Out of stock: air 30-60 days, sea 60-90 days.
How to make a purchase of Automatic Vertical Sliding Door Rapid Cooling Culture Medium Sterilizer YR05758-1?
You can buy by email ([email protected]), phone (+33 (0) 1 70 39 26 50) or through the official Kalstein website in your country.
How does the warranty work for Automatic Vertical Sliding Door Rapid Cooling Culture Medium Sterilizer YR05758-1?
All Kalstein equipment comes with a 1-year warranty against manufacturing defects. The warranty does not cover damage from improper installation or misuse. See our «terms and conditions» AQUI.
Can I request a quote online for Automatic Vertical Sliding Door Rapid Cooling Culture Medium Sterilizer YR05758-1?
Yes, you can request a quote for the Kalstein equipment you are interested in directly from our official website. Click AQUI.