Fully Automatic Glycosylated Hemoglobin Analyzer YR06657

Fully Automatic Glycosylated Hemoglobin Analyzer YR06657 — equipo de laboratorio Kalstein con especificaciones técnicas, características avanzadas y soluciones profesionales certificadas para uso científico.
Design and Technology (Functionality):
The YR06657 stands out for its advanced technology and fully modular design, which simplifies maintenance and component upgrades. Its LED detector system delivers superior performance and long service life without requiring preheating, optimizing operational efficiency. Temperature control is another key feature, with a range of 5°C to 40°C and a fluctuation of only ±0.2°C, ensuring stable analytical conditions. The HPLC pump supports pressures of up to 200 kg/cm² (2900 psi) and maintains a fluctuation of ±1%, improving result consistency. With the ability to perform STAT emergency testing at any time, this analyzer is well suited for high-throughput laboratory environments.Frequently Asked Questions:
What is the sample capacity of the YR06657 Analyzer? The YR06657 can analyze 15 samples per disk, increasing laboratory efficiency and throughput. Does the YR06657 require frequent maintenance? No daily maintenance is required. The sieve plate has a service life of 250 tests per unit, and the chromatography column can perform up to 2000 tests before recalibration is needed. What types of samples can be analyzed with the YR06657? This analyzer can process whole venous blood, capillary finger-stick blood, and hemolyzed samples, adapting to various collection conditions.Advantages and Disadvantages:
Advantages:- High accuracy and reliability: Thanks to HPLC technology and automatic calibration, results meet international standards.
- Modular design: Allows easy maintenance and upgrades without replacing the entire system.
- High sample throughput: Ideal for high-volume laboratories, processing up to 15 samples per disk.
- User-friendly operation: Automatic injection and STAT testing make it suitable for emergency situations and busy laboratories.
- Requires adequate workspace: Due to its size and modular configuration, sufficient bench space is necessary.
- Calibration dependency: Although automatic, the chromatography column requires recalibration after 2000 tests.
Product Use in the Field:
The YR06657 is an invaluable tool in clinical laboratories, hospitals, and diagnostic centers performing glycosylated hemoglobin testing. In healthcare settings, it is primarily used to assess glucose control in patients with diabetes. Its ability to analyze multiple samples quickly and accurately makes it essential in medical emergency situations, such as emergency departments where immediate results are required.Recommendations:
To maximize the performance of the YR06657 Glycosylated Hemoglobin Analyzer, it is recommended to follow a regular preventive maintenance routine, even though daily maintenance is not required. Ensure proper calibration before critical analyses and regularly check USB connections to guarantee smooth integration with your laboratory data management system.Technical Specifications
| Model | YR06657 |
| Detection Method | Ion-exchange High Performance Liquid Chromatography (HPLC) |
| Repeatability | ≤3.0% |
| Injection Method | Automatic piercing injection from original test tube |
| Sample Capacity | 15 samples/disk, CAL1 (QC1) & CAL2 (QC2), STAT emergency samples |
| Sample Type | Venous whole blood, finger-prick peripheral blood, or hemolyzed sample |
| Test Range | HbA1c: 4%–17%; 20–162 mmol/mol |
| Test Items | HbA1c and b-thalassemia A2 |
| Result Reporting | Simultaneous IFCC and NGSP results |
| USB Interface | Supports computer data communication and scanner connection |
| Component / Function | Description |
| Design | Fully modular |
| STAT Samples | Can be inserted at any time for automatic detection |
| LED Detector | High performance, long service life, no preheating required |
| Temperature Control | Column heating module; Range: 5°C to 40°C; Fluctuation: ±0.2∘C |
| HPLC Pump | Max pressure: 200 kg/cm² (2900 psi); Fluctuation: ±1% |
| Auto-Calibration | Complies with NGSP and IFCC standards to ensure accurate and reliable measurements |
| Item | Requirement / Lifespan |
| Sieve Plate | 250 tests/unit |
| Daily Maintenance | No daily maintenance required |
| Automatic Alarm | Alarm for missing or insufficient reagents |
| Chromatography Column | 2,000 tests/unit; single calibration required with calibrator |
Technical specifications
| Dimensions | L 65 × W 62 × H 73 cm |
|---|---|
| Weight | 75 kg |
| Manufacturer | Kalstein |
Frequently asked questions
How to know the prices of Fully Automatic Glycosylated Hemoglobin Analyzer YR06657?
To know the price of Fully Automatic Glycosylated Hemoglobin Analyzer YR06657, please send us an email with your request through the contact form AQUI.
What are the delivery times for Fully Automatic Glycosylated Hemoglobin Analyzer YR06657?
Delivery time depends on stock availability and freight type (air or sea). In stock: air 15-30 days, sea 45-60 days. Out of stock: air 30-60 days, sea 60-90 days.
How to make a purchase of Fully Automatic Glycosylated Hemoglobin Analyzer YR06657?
You can buy by email ([email protected]), phone (+33 (0) 1 70 39 26 50) or through the official Kalstein website in your country.
How does the warranty work for Fully Automatic Glycosylated Hemoglobin Analyzer YR06657?
All Kalstein equipment comes with a 1-year warranty against manufacturing defects. The warranty does not cover damage from improper installation or misuse. See our «terms and conditions» AQUI.
Can I request a quote online for Fully Automatic Glycosylated Hemoglobin Analyzer YR06657?
Yes, you can request a quote for the Kalstein equipment you are interested in directly from our official website. Click AQUI.