Kalstein

Technical Glossary and Key Terminology for the YR06116 LED Double-Head Surgical Lamp

By Kalstein · Published on:

Category:articulos-de-productos

Technical Glossary and Key Terminology for the YR06116 LED Double-Head Surgical Lamp

Discover essential terminology and technical specifications for the YR06116 LED Double-Head Surgical Lamp, ensuring effective operation and understanding of thi

3D available

Technical Glossary and Key Terminology for the YR06116 LED Double-Head Surgical Lamp

The YR06116 LED Double-Head Surgical Lamp represents a significant advancement in surgical lighting technology, designed to meet the rigorous demands of modern operating rooms. Understanding the technical terminologies associated with this device is crucial for surgeons, technicians, and healthcare providers. This article aims to provide a comprehensive glossary of terms related to the YR06116, alongside detailed specifications and applications.

Understanding the YR06116 Surgical Lamp

The YR06116 features a state-of-the-art design aimed at enhancing visibility and safety during surgical procedures. Its dual head configuration allows for better lighting coverage, effectively eliminating shadows that can obstruct a surgeon's view. This section introduces the essential functions and operational principles of the lamp.

Technical Specifications of the YR06116

SpecificationDetails
ModelYR06116
Illuminance160,000 Lux
Service Life60,000 hours with no need to change bulbs
Temperature Resistant Detachable Handle≤160°C
Color Temperature Adjustment3500K to 5000K in six levels
Brightness AdjustmentAutomatic 6-stage continuous light adjustment

Technical Glossary

This glossary defines key terms relevant to the YR06116 LED Double-Head Surgical Lamp:

TermDefinition
IlluminanceThe amount of light that falls on a surface, measured in Lux.
Color TemperatureA measure of the color of light emitted by a lamp, expressed in Kelvin (K).
Brightness AdjustmentThe ability to modify the intensity of light, enhancing visibility according to surgical requirements.
Detachable HandleA handle that can be removed for efficient sterilization and maintenance.
LED TechnologyLight Emitting Diode technology known for energy efficiency and long operational life.
360° Light DistributionA feature that enables light to be emitted uniformly around the lamp, ensuring comprehensive illumination.
Safety StandardsRegulations and guidelines that ensure the safety and effectiveness of medical devices.
Manual FocusingA feature allowing operators to adjust light focus manually for optimal visibility.
High Definition Camera SystemA system used in conjunction with the lamp for video transmission and remote teaching capabilities.

Applications of the YR06116

The YR06116 is employed in various medical settings, including surgical rooms and critical care environments. Its adjustable features ensure it meets the specific needs of different procedures. Understanding the application of the surgical lamp enhances its effectiveness in clinical practice.

Equipment Maintenance and Care

Proper maintenance of the YR06116 ensures longevity and optimal performance. Regular checks on the detachable handle, lens cleanliness, and lighting mechanisms are crucial. This section outlines best practices for maintaining the surgical lamp.

Frequently Asked Questions

What is the service life of the YR06116?

The YR06116 surgical lamp has a service life of approximately 60,000 hours, which means no need for bulb replacements during this period.

How do I adjust the brightness on the YR06116?

The YR06116 features an automatic 6-stage continuous light adjustment, allowing you to easily modify brightness according to the surgical needs.

What are the lighting capabilities of the YR06116?

The YR06116 offers an impressive illuminance of 160,000 Lux, ensuring excellent visibility in deep cavities during surgical procedures.

Can the handle be sterilized?

Yes, the temperature resistant detachable handle can be sterilized at temperatures up to 160°C, meeting aseptic requirements in operating rooms.

What is the color temperature range of the YR06116?

The color temperature can be adjusted from 3500K to 5000K in six levels, allowing customization for different surgical environments.

How does the manual focusing feature work?

The manual focusing feature allows operating room staff to adjust the beam focus, providing clarity and precision in surgical lighting.

What makes the YR06116 suitable for digital operating rooms?

With options for high-definition camera integration and various transfer interfaces, the YR06116 is ideal for digital operating rooms, facilitating remote teaching and data archiving.

If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.

Want to explore this device in depth?

Check the full technical datasheet of LED Double-Head Surgical Lamp without Shadows YR06116 with all specifications, dimensions, accessories and quote options.
View product datasheet →