Technical Performance and Safety of the YR04988 Circulating Bathroom Cooling and Heating System
Product Description
The YR04988 model from the circulating cooling and heating series is designed to provide a stable liquid temperature environment ranging from -20°C to 100°C. This system is utilized across various applications including electronic component temperature control, chemical synthesis, and life sciences experiments. Its technical performance and safety features make it a reliable choice for professional laboratories.
Features
- PID temperature control for precise temperature regulation.
- Overheating alarm system for enhanced safety.
- Low water level alarm to prevent damage.
- High-efficiency compressor cooling that operates quietly and is fluorine-free.
- High flow and pressure circulation pump for optimal performance.
- 304 stainless steel tank ensuring durability and resistance to corrosion.
- Open-top design for easy access and suitable for tank experiments.
| Model | Temperature Range (°C) | Stability (°C) | Flow Rate (L/min) | Lift (m) | Capacity (L) | Open Dimensions (mm) | Depth (mm) | Product Size (WxDxH) |
|---|---|---|---|---|---|---|---|---|
| YR04986 | -5~100 | ±0.05 | 14 L/min | 12 | 10 | 160x140 | 180 | 450 x 360 x 820 |
| YR04987 | -10~100 | |||||||
| YR04988 (current) | -20~100 | |||||||
| YR04989 | -30~100 | 600 x 540 x 950 | ||||||
| YR04990 | -40~100 | |||||||
| YR04991 | -5~100 | 20 | 210x210 | 500 x 400 x 820 | ||||
| YR04992 | -10~100 | |||||||
| YR04993 | -20~100 | |||||||
| YR04994 | -30~100 | 600 x 570 x 950 | ||||||
| YR04995 | -40~100 | |||||||
| YR04996 | -5~100 | 30 | 310x280 | 600 x 480 x 820 | ||||
| YR04997 | -10~100 | |||||||
| YR04998 | -20~100 | |||||||
| YR04999 | -30~100 | 700 x 650 x 950 | ||||||
| YR05000 | -40~100 |
Market Price
The current market price of the YR04988 Circulating Bathroom Cooling and Heating system is approximately $617.00 USD or €1234. This pricing reflects its advanced technology and robust features, making it a competitive option in the market for laboratory equipment.
Frequently Asked Questions
What is the temperature range of the YR04988?
The YR04988 has a temperature range from -20°C to 100°C, making it suitable for various applications requiring precise temperature control.
How does the PID control work in the YR04988?
The PID control system continuously calculates an error value as the difference between a desired setpoint and a measured process variable, adjusting the output to minimize the error. This ensures accurate and stable temperature regulation.
Is the YR04988 safe for laboratory use?
Yes, the YR04988 includes safety features such as an overheating alarm and low water level alarm, enhancing its reliability and safety during operation.
What materials are used in the construction of the YR04988?
The tank of the YR04988 is made from 304 stainless steel, ensuring durability and resistance to corrosion, which is essential for laboratory environments.
Can the YR04988 be used for chemical synthesis?
Yes, the YR04988 is suitable for chemical synthesis as its temperature stability and control features allow for precise temperature management during reactions.
What applications is the YR04988 ideal for?
The YR04988 is ideal for applications such as electronic component temperature control, chemical synthesis, and life sciences experiments.
How can I request a quote for the YR04988?
You can request a quote for the YR04988 by contacting our sales team through our website or directly.
Pros and Cons
Pros
- Wide temperature range from -20°C to 100°C.
- High-efficiency cooling system with low noise operation.
- Durable construction with stainless steel tank.
- Advanced safety features for user protection.
- Ideal for diverse laboratory applications.
Cons
- Initial investment may be higher compared to basic models.
- Maintenance may require professional assistance.
Field Usage
The YR04988 is widely used in laboratories requiring precise temperature control for experiments and processes. Its applications include:
- Testing electronic components where temperature stability is critical.
- Synthesizing chemicals at controlled temperatures to ensure reaction efficacy.
- Conducting life sciences experiments demanding exact temperature conditions.
Recommendations
To maximize the performance of the YR04988, consider the following recommendations:
- Ensure regular maintenance checks to keep the system in optimal condition.
- Calibrate the PID control settings as per specific application requirements.
- Monitor liquid levels frequently to avoid low-water incidents.
- Utilize appropriate connectors and hoses to maintain efficient circulation.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.