Vertical normal laboratory freeze dryer YR05190

The Vertical normal laboratory freeze dryer YR05190 combines technical features for laboratory routines, operational continuity and a coherent equipment selection process.
This page provides an overview of the Vertical normal laboratory freeze dryer YR05190, including selection criteria, investment factors, operational advantages and maintenance recommendations. The aim is to support an informed decision before requesting a quotation.
This Kalstein model is available for laboratories across Latin America, Europe, Africa, the Middle East and Asia, with selection criteria adapted to the diversity of local purchasing, installation and support conditions in each region.
Key factors to consider

Before selecting the Vertical normal laboratory freeze dryer YR05190, confirm workflow, available space, required accessories and installation conditions. This prevents oversizing the purchase and helps prepare a more accurate quotation.
Its use is oriented to laboratory routines that require observation, control and operational continuity.
Across these markets, evaluation should consider varied local contexts such as international laboratory procurement spanning Latin America, Europe, Africa, the Middle East and Asia and match the product to the real workload of the laboratory in each country.
Market price range

The investment should be evaluated according to configuration, required accessories, installation conditions and available technical support.
The final price may vary according to configuration, accessories, logistics, warranty and territorial availability. Compare the technical sheet with the real laboratory workload before confirming the investment.
Budget comparison varies by country and should include the regulatory requirements specific to each market, the electrical conditions of each region, accessories, logistics and after-sales support.
Value for money

Equipment value depends on operational stability, required accuracy, ease of maintenance and accessory availability.
Value for money should be reviewed together with equipment stability, after-sales support, technical documentation and expected service life. A well-matched selection reduces downtime and improves return on investment.
Advantages and disadvantages

Its use is oriented to laboratory routines that require observation, control and operational continuity.
Main advantages include specialized application, integration with laboratory routines and accessory configuration. Limitations may include installation requirements, user training and preventive maintenance to preserve performance.
Expected lifespan based on use and maintenance

Model YR05190 (current) Lyophilization area 0.12㎡ Condenser capacity 3-4 L/24h Condenser temperature -55 ℃ (-80 ℃ optional) Vacuum degree < 10 Pa Material tray Ф200mm, 4 layers Bulk capacity 1.2 l, 10 mm thickness Φ12mm vial capacity 920 pieces Φ16mm vial capacity 480 pieces Φ22mm vial capacity 260 pieces Cooling Air, with air currents, ambient temperature≤25℃ Voltage 220V, 50Hz Host dimension 556×460×(720+430) millimeter Power 750W Host weight 62 kg
Service life depends on usage frequency, cleaning, storage, calibration when applicable and adherence to technical recommendations. A structured maintenance plan helps preserve accuracy, safety and operational continuity.
A support and spare-parts network deployed across Latin America, Europe, Africa, the Middle East and Asia helps preserve service continuity and plan preventive maintenance without extended downtime.
Specifications table for the Vertical normal laboratory freeze dryer YR05190

Vertical normal laboratory freeze dryer YR05190
Características
- Refrigeración sin CFC
- Curvas de secado de pantalla LCD, interfaz en inglés
- Gran apertura de condensador, condensador con función de precongelación
- Compresor de bajo ruido, buena eficiencia, larga vida útil
- El condensador y el panel de operación son todos de acero inoxidable
- La cámara de secado con vidrio orgánico es segura y visible
- El estante y la bandeja son de acero inoxidable, el espacio entre bandejas se puede personalizar
- Pequeño volumen, operación fácil y conveniente
- La válvula de nitrógeno es opcional
- El dispositivo de prueba de punto eutéctico es opcional
- La interfaz de comunicación es opcional
- La refrigeración en cascada es opcional, aplicada para dispositivos de -80 ℃
Descripción técnica
| Model | YR05190 (current) |
| Lyophilization area | 0.12㎡ |
| Condenser capacity | 3-4 L/24h |
| Condenser temperature | -55 ℃ (-80 ℃ optional) |
| Vacuum degree | < 10 Pa |
| Material tray | Ф200mm, 4 layers |
| Bulk capacity | 1.2 l, 10 mm thickness |
| Φ12mm vial capacity | 920 pieces |
| Φ16mm vial capacity | 480 pieces |
| Φ22mm vial capacity | 260 pieces |
| Cooling | Air, with air currents, ambient temperature≤25℃ |
| Voltage | 220V, 50Hz |
| Host dimension | 556×460×(720+430) millimeter |
| Power | 750W |
| Host weight | 62 kg |
Frequently Asked Questions about the Vertical normal laboratory freeze dryer YR05190
How do I choose the right vertical normal laboratory freeze dryer yr05190 for my laboratory?
Selection should start from workload, critical technical parameters, available space and frequency of use. Kalstein can support the comparison between operational needs, budget and maintenance requirements to avoid choosing equipment that is oversized or insufficient.
What should I review before requesting a quotation?
Review the model, technical specifications, required accessories, electrical conditions, consumables, delivery timing and installation needs. With this information, the quotation can be prepared more accurately and aligned with the laboratory workflow.
Does Kalstein provide guidance for this type of equipment?
Yes. The commercial and technical team can support product evaluation, explain differences between models, answer application questions and advise on preventive maintenance, spare parts and documentation required for a secure purchase.
What maintenance helps extend the equipment lifespan?
Follow the manufacturer manual, perform regular cleaning, verify calibrations or controls when applicable, avoid workload abuse and keep maintenance records. Stable use and preventive routines reduce failures and improve operational continuity.