The YR06163 Digital Stationary Veterinary X-ray is an essential tool for veterinary practices, providing high-quality imaging for diagnostics. Understanding the warranty terms, expected lifespan, and replacement strategies of this model will help ensure optimal performance and longevity. This article aims to provide a comprehensive overview of the warranty, expected operational lifespan, and a structured replacement plan for the YR06163, benefiting operators and veterinary professionals alike.

Warranty Terms for YR06163

The warranty for the YR06163 is a critical aspect that operators must understand. This section details the coverage offered with the purchase, including parts and labor, and identifies any exclusions that may apply.

  • Duration: Typically, the warranty period lasts for two years from the date of purchase, covering manufacturing defects.
  • Coverage: The warranty includes parts and labor for repairs resulting from manufacturing defects or material failure under normal use.
  • Exclusions: The warranty does not cover damage caused by misuse, neglect, unauthorized modifications, or failure to comply with operational guidelines.

Expected Lifespan of the YR06163

Understanding the expected lifespan of the YR06163 is vital for planning and budgeting. Various factors can influence its operational longevity, including usage patterns, maintenance protocols, and environmental conditions.

  • Mean Time Between Failures (MTBF): The YR06163 has a predicted MTBF of 10,000 hours of operation, which equates to several years of typical use in a veterinary environment.
  • Factors Affecting Lifespan: Key factors that may affect the lifespan include the frequency of use, proper maintenance, and adherence to operational guidelines.
  • Common Indicators of End-of-Life: Operators should be aware of signs indicating the need for replacement, such as frequent error codes, degradation in image quality, and electrical anomalies.

Replacement Planning for YR06163

A proactive replacement plan can minimize downtime and maintain operational efficiency. This section outlines steps for effective replacement planning.

  • Replacement Strategy: Establish a timeline for assessments based on usage and performance metrics. Regular evaluations are essential to determine if replacement is necessary.
  • Budget Planning: Allocate funds for future replacement based on expected depreciation rates and potential service costs.
  • Service Intervals: Schedule regular maintenance checks every 6-12 months to prolong the lifespan and ensure optimal performance.

Technical Specifications of YR06163

SpecificationValue
ModelYR06163
Maximum output power20 kW
Range of tube current32~320 mA
Tube voltage range of radiography40 kV~120 kV
Range of exposure time10 ms~5000 ms
mAs range0.32 mAs~320 mAs
Input voltage rangeAC 220V±22V
Communication interfaceRS-232
Other featuresCapacity lock automatically, fault diagnosis automatically, self-protection
Max. Tube voltage120 kV
FocusSmall focus: 1.0 mm, Large focus: 2.0 mm
Anode input powerSmall focus: 20 kW, Large focus: 40 kW
Anode speed2800 R/M
Target angle17.5°
Anode heat content100 kJ (140 kHU)

Frequently Asked Questions

What is the warranty coverage for the YR06163 Digital Stationary Veterinary X-ray?

The warranty for the YR06163 covers parts and labor for manufacturing defects or material failure under normal use for two years from the purchase date.

How long is the expected operational lifespan of the YR06163?

The YR06163 typically has an expected operational lifespan of around 10,000 hours, depending on usage and maintenance practices.

What are the common signs that the YR06163 may need replacement?

Common signs include frequent error codes, decreasing image quality, and electrical issues that may indicate the device is nearing the end of its lifespan.

How can I assess the performance of the YR06163 regularly?

Regular assessments should include checking for error codes, verifying image quality, and scheduling maintenance checks every 6-12 months.

What should be included in the replacement budget for the YR06163?

When budgeting for replacement, consider depreciation rates, potential service costs, and any future upgrades necessary for maintaining operational efficiency.

What maintenance practices can prolong the lifespan of the YR06163?

To prolong lifespan, ensure regular cleaning, adhere to operational guidelines, and perform preventative maintenance at scheduled intervals.

Where can I request a quote for the YR06163 Digital Stationary Veterinary X-ray?

You can request a quote on Kalstein Plus, where you will find competitive pricing and detailed product information.

If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.

Want to explore this device in depth?

Check the full technical datasheet of Digital Stationary Veterinary X-rays YR06163 with all specifications, dimensions, accessories and quote options.
View product datasheet →