Multimode Microplate Reader YR07004

The YR07004 is a high-end multimode microplate reading system (ABS, FL, LUM, TRF) specifically designed for medical, biological, and pharmaceutical research ins
The multimode microplate reader YR07004 offers exceptional processing capabilities through its advanced monochromator system and specialized optics with high-sensitivity photomultiplier tubes. The equipment allows for rapid spectral scanning, quantification of nucleic acids without dilution using u-Nano plates, and assays with dual automatic injectors. Its 10 GB data storage capacity and advanced connectivity via Ethernet, USB, and FTP protocols optimize information transfer. The device's structure is designed to ensure a long lifespan, low operational noise, and seamless integration into hospital management networks. It represents a cutting-edge comprehensive solution for laboratories seeking maximum efficiency and analytical reliability.
Advanced Design and Technology
4 Mode Versatility: Offers complete detection solutions including absorbance (UV/Vis), fluorescence, luminescence, and time-resolved fluorescence (TRF).
High Precision Optics: Utilizes an advanced monochromator system for absorbance (200 to 1000 nm) and filter-based optics with dichroic mirrors for fluorescence, ensuring high light transmission and sensitivity.
Control and Luminescence Performance: Incorporates a photomultiplier tube (PMT) optimized for weak signals, preventing saturation and minimizing crosstalk between wells (crosstalk ≤0.005%).
Ultramicro u-Nano Plate: Allows for rapid, undiluted quantification of 16 or 96 nucleic acid and protein samples simultaneously using a minimum volume of 2 to 4 μL.
Dual Automatic Injector (Optional/Integrated): Designed for instant luminescence assays and $Ca^{2+}$ flow, with software protection to prevent overflow.
Frequently Asked Questions (FAQ)
What types of plates does the instrument support? It is compatible with a wide range of supports, including 6, 12, 24, 48, 96, and 384 well plates, PCR plates, and ultramicro u-Nano plates.
How is spectral scanning performed in absorbance? It employs a long-lasting xenon lamp (up to $10^9$ flashes) capable of scanning the entire spectrum of a sample between 200 and 1000 nm in 1 nm increments in less than 15 seconds.
Can data be managed remotely? Yes, the test data report can be directly uploaded to a PC server via an Ethernet connection and FTP protocol.
Advantages and Disadvantages
Key Advantages:
Extreme Sensitivity: Highly optimized detection limits, such as 1 pM in fluorescence and up to 15 amol/well in luminescence.
Dynamic Stirring: Features three independent stirring modes (linear, circular, and doubly circular) with adjustable speed to optimize kinetic reactions.
Intelligent Interface: 10-inch capacitive touchscreen operated via the ReaderIt-II analysis software and fully compatible with 64-bit Windows 10/11.
Disadvantages / Considerations:
Infrastructure Requirement: As a high-end equipment with multiple optical and mechanical modules (33 kg), it requires a stable and dedicated work surface.
Calibration Curve: The use of multiple analytical modes and advanced accessories (such as the automatic injector) requires personnel with specific technical training for full utilization of the system.
Product Use in the Field and Recommendations
Ideal Applications: Research laboratories in life sciences, pharmaceutical quality control, trace analysis in biomedicine, immunoassays, and gene expression studies.
Recommended Maintenance: Periodically check the status of the modular filters using QR codes to ensure parameter accuracy and clean the automatic injector conduits after assays with reactive samples.
Operation Recommendation: Use the optical performance validation plate for ABS during installation and operational qualification stages to ensure traceability of absorbance measurements.
| Model | YR07004 |
|---|---|
| ABS | |
| Plate | 6 well plate, 12 well plate, 24 well plate, 48 well plate, 96 well plate, 384 well plate, 96/384 PCR plate, 16/96 ultramicro u-Nano plate |
| Reading time (spectrum) | 200~1000 nm <15 s (1 nm step) |
| Light source | Xenon lamp |
| Wavelength accuracy | 2 nm |
| Wavelength repeatability (SD) | 0.2 nm |
| Half width (FWHM) | <2.5 nm |
| Detector | PD×2 |
| Wavelength range | 200~1000 nm, 1 nm step |
| Measurement range | 0-4 DE |
| Resolution | 0.0001 DE |
| Accuracy at 450 nm | Precision mode: ±(1.0%+0.003OD) @(0.0-2.0OD]; ±2%>@(2.0-3.0OD] |
| Repeatability at 450 nm | CV<1.0% or SD<0.003 fast (0.0-3.0 OD]; CV<0.5% or SD<0.003 precise (0.0-3.0 OD] |
| Scattered light | 0.1 % at 220 nm |
| Linear at 450 nm | R²≥0.999 @ [0.0 - 3.0 OD] |
| Reading time | 96 well plate: fast <15 s (A1 to H1) |
| Fluorescence | |
| Reading mode | Highlighted readings |
| Excitation light source | Xenon lamp |
| Detector | PMT |
| Wavelength range | EX: 200~1000 nm; EM: 270~850 nm |
| EX / EM filter | EX485 / EM530, EX523 / EM564, EX624 / EM692 (other wavelengths can be substituted) |
| Linear dynamic range | ≥6 logs |
| Detection limit | 1 pM (optimization condition) |
| LUMINESCENCE | |
| Detector | PMT |
| Detection limit | ≤15 amol/well on 96 well white plate with ATP flash |
| Linear dynamic range | ≥6 logs |
| Crosstalk | ≤0.005% |
| Wavelength range | 200-850 nm |
| Filter | LUMINESCENCE |
| TRF | |
| EX / EM filter | EX365 / EM612 |
| Detection limit | 0.02 pM (optimization condition) |
| Software | |
| Analysis software | ReaderIt-II Software |
| Basic parameter | |
| Reading type | End point, kinetics, spectral scanning, and well scanning |
| Plate | 6 well plate, 12 well plate, 24 well plate, 48 well plate, 96 well plate, 384 well plate, 96/384 PCR plate, 16/96 ultramicro u-Nano plate |
| Accessories | 16/96 ultramicro u-Nano plate, auto-injector |
| Stirring mode | Linear, circular, double circular (force and speed adjustable) |
| Incubation temperature | TA. +4 °C~45 °C |
| Temperature accuracy | ±0.5 °C at 37 °C |
| Software interface | Chinese / English |
| Screen size | 10 inches |
| Operation method | Capacitive touchscreen, mouse |
| Data capacity | 10 GB |
| Compatibility | Compatible with PC software, Windows 10 and later versions, 64 bits. |
| Network transmission | The test data report can be uploaded to the PC server via FTP. |
| Instrument ports | 2 USB A ports, 1 USB B port, 1 Ethernet port, RS232 bus interface (connected to the injector) |
| Power supply | AC 100-240 V, 50-60 Hz |
| Packing dimensions | 80×78×80 cm |
| Weight | 33 kg |
| Accessory parameter | |
| u-Nano | |
| Sample number | u-Nano 16: 1~16, u-Nano 96: 1~96 |
| Sample detection volume | 2-4 μL |
| Automatic injector | |
| Support plate | 6-384 well plate |
| Quantity | 1/2 |
| Dispensing volume | 5-1000 μL, 1 μL increment |
| Liquid injection speed | 125-500 μL/s |
| Accuracy | ±1 μL at 5-50 μL; ±2% at 51-1000 μL |
| Residual liquid collection | 25 ml |
Technical specifications
| Manufacturer | Kalstein |
|---|
Video Multimode Microplate Reader YR07004
Frequently asked questions
How to know the prices of Multimode Microplate Reader YR07004?
To know the price of Multimode Microplate Reader YR07004, please send us an email with your request through the contact form AQUI.
What are the delivery times for Multimode Microplate Reader YR07004?
Delivery time depends on stock availability and freight type (air or sea). In stock: air 15-30 days, sea 45-60 days. Out of stock: air 30-60 days, sea 60-90 days.
How to make a purchase of Multimode Microplate Reader YR07004?
You can buy by email ([email protected]), phone (+33 (0) 1 70 39 26 50) or through the official Kalstein website in your country.
How does the warranty work for Multimode Microplate Reader YR07004?
All Kalstein equipment comes with a 1-year warranty against manufacturing defects. The warranty does not cover damage from improper installation or misuse. See our «terms and conditions» AQUI.
Can I request a quote online for Multimode Microplate Reader YR07004?
Yes, you can request a quote for the Kalstein equipment you are interested in directly from our official website. Click AQUI.