The Fetal Doppler Monitor YR02180 is an essential tool in prenatal monitoring and care, allowing healthcare professionals to accurately monitor the health of both the fetus and the mother during pregnancy. This device combines advanced technology and ergonomic design to provide precise measurements, ensuring reliable monitoring of fetal heart rate and other vital parameters. Its ease of use and clear readings make it ideal for use in hospitals and prenatal care clinics.
Product Description
The Fetal Doppler Monitor YR02180 is designed to offer comprehensive monitoring of fetal heart rate, respiratory rate, oxygen saturation (SPO2), temperature, and non-invasive blood pressure (NIBP). Below is the detailed table of technical specifications for the product:
|
Technical Specifications |
Model YR02180 |
|
ECG |
Main Mode: 5 leads (RA, LA, LL, RL, V) |
|
Connection Method: I, II, III, AVR, AVL, AVF, V |
|
|
Lead Mode: 3 leads (RA, LA, LL) |
|
|
Connection Method: I, II, III |
|
|
Gain: x250, x500, x1000, x2000 |
|
|
Accuracy: ±5% |
|
|
Resolution: 1 bpm |
|
|
Sensitivity: 200 (uVp-p) |
|
|
Differential input impedance: ≥5MΩ |
|
|
Heart Rate |
Measurement Range: 40~240 bpm |
|
Accuracy: ±3 bpm |
|
|
Resolution: 1 bpm |
|
|
Sensitivity: 200 UVp-p |
|
|
Respiration |
Method: Impedance between R-F (RA-LL) |
|
Impedance Measurement Range: 0.3~3.0 MΩ |
|
|
Bandwidth: 0.1~2.5 Hz |
|
|
Respiratory Rate: Adult: 7120 BrPM, Neo/Ped: 7150 BrPM |
|
|
Resolution: 1 BrPM |
|
|
Accuracy: ±2 BrPM |
|
|
NIBP |
Method: Oscillometric |
|
Measurement Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240 (Min) |
|
|
Measurement Period in STAT Mode: 5 minutes |
|
|
Pulse Rate: 40240 bpm / 40150 bpm |
|
|
Alarm Type: SYS, DIA, MEAN |
|
|
Resolution: 1 mmHg |
|
|
SPO2 |
Display: SPO2 value, waveform, Pulse |
|
Measurement Range: 0~100% |
|
|
Resolution: 1% |
|
|
Accuracy: 70~99% (±2%) |
|
|
Pulse Rate: 0~300 bpm |
|
|
TEMP |
Channel: 2 |
|
Measurement and Alarm Range: 0~50ºC |
|
|
Resolution: 0.1ºC |
|
|
Accuracy: 0.1ºC |
|
|
Update Interval: around 1 second |
|
|
Mean Time Constant: 10 seconds |
The YR02180 enables detailed and continuous monitoring, which is crucial in assessing fetal health during pregnancy. With features like ±3 bpm accuracy in heart rate monitoring and a resolution of 1 bpm, it ensures real-time, reliable results.
Market Pricing
The price of the Fetal Doppler Monitor YR02180 can vary depending on the supplier and region, generally ranging from $800 to $1,500 USD. Compared to other models on the market, the YR02180 offers excellent value for money, especially considering its precision and the range of monitoring functions it integrates. To get a personalized and detailed quote, you can visit the Kalstein Plus platform, where you can request an offer tailored to your specific equipment needs.
Frequently Asked Questions
-
What is the purpose of the Fetal Doppler Monitor YR02180?
-
This monitor is designed for continuous tracking of fetal heart rate, respiration, and other vital signs of the mother and fetus, providing essential information for prenatal care.
-
-
What is the accuracy of the heart rate measurement?
-
The YR02180 offers an accuracy of ±3 bpm, ensuring reliable and precise monitoring of fetal health during pregnancy.
-
-
Is it suitable for use in hospitals and clinics?
-
Yes, this monitor is ideal for use in hospital settings and clinics due to its ease of use and clear readings, making it an indispensable tool for healthcare professionals.
-
-
What kind of alarms does the monitor offer?
-
The YR02180 includes configurable alarms for blood pressure (SYS, DIA, MEAN), allowing continuous supervision and the detection of any abnormalities during monitoring.
-
-
How does the device measure SPO2?
-
The monitor uses a non-invasive sensor to measure oxygen saturation (SPO2), displaying the results in both numerical and waveform formats, facilitating data interpretation.
-
-
Can it be integrated with other hospital monitoring systems?
-
Yes, the YR02180 is compatible with other monitoring systems, making it easy to integrate into hospital facilities and advanced care centers.
-
Advantages and Disadvantages
|
Advantages |
Disadvantages |
|
High accuracy in heart rate measurement (±3 bpm). |
May require initial training for optimal use. |
|
Compact design, easy to transport between rooms. |
Cost may be high for clinics with limited budgets. |
|
Compatible with other hospital monitoring systems. |
Periodic calibration is necessary to maintain accuracy. |
|
Provides detailed real-time monitoring. |
Requires a controlled environment for accurate measurements. |
|
Clear display for data visualization. |
Sensor sensitivity may be affected by electrical interference. |
|
Advanced alarm functions to detect anomalies. |
May not be suitable for long-term portable monitoring. |
|
Wide measurement range for SPO2 and temperature. |
Proper equipment maintenance is crucial for durability. |
|
Easy integration with clinical data systems. |
Requires a constant power supply for continuous operation. |
Field Use of the Product
The Fetal Doppler Monitor YR02180 is particularly valuable in hospitals and clinics specializing in prenatal care. Its ability to provide accurate and continuous readings of fetal heart rate makes it an essential tool for monitoring high-risk pregnancies. Additionally, its compact design makes it suitable for use in various areas of a healthcare facility, from emergency rooms to prenatal consultations, ensuring continuous monitoring of both the fetus and the mother’s well-being.
The advanced technology of the YR02180 allows for the quick detection of potential anomalies in fetal health, which can be critical for clinical decision-making. Healthcare professionals appreciate its ability to deliver precise measurements even in challenging situations, such as multiple pregnancies or conditions that affect heart rate. This ensures personalized and high-quality care for each patient.
Recommendations
To maximize the lifespan and effectiveness of the Fetal Doppler Monitor YR02180, it is important to follow some basic recommendations. First, ensure regular calibration of the device to maintain the accuracy of its readings. Additionally, regularly cleaning the sensors and equipment helps to avoid potential interference and ensures optimal performance.
It is recommended that medical staff are properly trained in the use of the device, as this will allow them to take full advantage of its advanced functions and ensure effective monitoring. If you are interested in purchasing the Fetal Doppler Monitor YR02180 for your medical center, I encourage you to request a personalized quote through the Kalstein Plus platform. There, you can obtain an offer tailored to your needs and ensure that your team has access to the best available technology for prenatal care.
With these features and the versatility it offers, the Fetal Doppler Monitor YR02180 is an excellent choice for healthcare facilities looking to improve the quality of prenatal monitoring. https://kalstein.net/en/ In addition to its technical capabilities, the after-sales service and quality guarantee offered by the provider ensure a safe long-term investment. https://kalstein.net/en/product/doppler-fetal-monitor-yr02180/