Ways to calibrate a Rotary Evaporator
Calibration of a rotary evaporator is a mandatory task to ensure good performance and operational safety in the laboratory.
Calibration of a rotary evaporator is a mandatory task to ensure good performance and operational safety in the laboratory. There are several methods to calibrate a rotary evaporator and they should be chosen based on the application, complexity and economic requirements. Researchers have tested and compared several ways to calibrate a rotary evaporator to determine which offers the greatest efficiency in different situations.
In a recent study, methods of calibrating a rotary evaporator by measuring steam temperature, steam pressure and solution concentration were compared. Vapor temperature was monitored using an infrared thermograph system, which allowed an accurate and reliable measurement. The vapor pressure was obtained by means of a vacuum pump, and indicates the degree of pressure at which the vapor passes through the equipment and how this influences the evaporation efficiency. The concentration of the solution was determined by means of a glucose and serum analyzer with an infrared detector.
It is suitable for experiment of evaporation, distillation or separation of chemicals. It usually works with water circulating vacuum pump and...
Large capacity and large opening of evaporating flask give larger evaporation surface. The evaporating flask keeps rotating when it is constantly...
Large capacity and large opening of evaporating flask give larger evaporation surface. The evaporating flask keeps rotating when it is constantly heated by water bath, and solvent evaporates more efficiently under vacuum condition. It can be used for pilot-scale production in biology engineering, pharmaceutical industry, chemical industry and food processing. It usually works with water circulating vacuum pump, diaphragm vacuum pump, recirculating chiller, constant-temperature circulator, low temperature circulating pump, etc.
Model | YR02307 | YR02308 | YR02309 | YR02310 | |||||
Evaporating flask | 5L, flange opening: Φ50mm | 10L, flange opening: Φ125mm | 20L, flange opening: Φ125mm | 50L, flange opening: Φ125mm | |||||
Receiving flask(L) | 3 | 5 | 10 | 20 | |||||
Speed-regulation | DC stepless speed-regulation | ||||||||
Power supply | 220V-240V, 50/60Hz | 3~, 380V, 50Hz | |||||||
Overall power(kW) | 2.3 | 3.8 | 6.3 | 6.3 | |||||
Rotation speed (rpm) | 20~140 | 20~130 | 20~130 | 20~110 | |||||
Power of motor(w) | 250 | 250 | 250 | 250 | |||||
Condenser | Vertical type double coil pipe |
Vertical type, Main + auxiliary triple-circulating cold traps |
|||||||
Bath material | Stainless steel 304 | ||||||||
Temperature range | RT~99℃ | ||||||||
Temperature display | Digital display | ||||||||
Sealing | 20mbar/h | ||||||||
Evaporating Speed (L/h)
|
Water | 2.0 | 3.2 | 5.0 | 9.0 | ||||
Ethanol | 5.4 | 8.6 | 14.3 | 24.5 | |||||
Lifting function | Motorized Lift | Motorized lift + Manual lift | |||||||
Elevating stroke(mm) | 0~150 | 0~160 | 0~190 | 0~180 | |||||
Dimensions(mm) | 835W×400D×1090H | 990W×550D×1655H | 1195W×635D×2070H | 1345W×770D×2140H | |||||
Net Weight(kg) | 60 | 85 | 115 | 200 |
The rotary evaporator is an essential piece of equipment in the modern laboratory and is used in a wide range
A rotary evaporator is a useful tool employed in biology, chemistry, and other scientific fields for tasting liquid substances. It is a very
A rotary evaporator is laboratory equipment used to remove or recover solvents at low pressure. This instrument is used to evaporate
Calibration of a rotary evaporator is a mandatory task to ensure good performance and operational safety in the laboratory.
In this section you can find our Rotary Evaporator in operation, packed, receiving service, etc.
A rotary evaporator is laboratory equipment used to remove or recover solvents at low pressure. This instrument is used to evaporate substances through the distillation process, to later be condensed and finally separated into its components one by one, thanks to its specific boiling points.
The sample to be processed is inserted into the separation flask, which is submerged in the water, and subsequently the thermoregulated bath and the rotation system are turned on, then by the action of the vacuum pump, the pressure is reduced, allowing the solvents to separate from the solutes, and that these solvents will be distilled in the condensation tube at low temperature and collected in the flask intended for it.
To find out the price of the Rotaif Evaporator, please send us an email with your request via the contact form.
Of course, you can request a quote for the Kalstein team of your interest, directly from our official website. Once you have identified your preferred model, click HERE
Error: Contact form not found.