The High Temperature Viscometer models YR05843, YR05844, YR05845, and YR05846 are cutting-edge instruments designed for precise viscosity measurement under high-temperature conditions. Featuring a user-friendly liquid-crystal display, these viscometers provide clear readings and easy navigation through their interface. The models operate at 18 distinct speeds ranging from 0.5 to 100 r/min, allowing users to tailor the testing parameters according to their specific requirements.

These viscometers have been engineered with several rotor configurations to accommodate various testing needs. For instance, the YR05843 model operates with 18, 25, 31, and 34 rotors, while the other models feature a standard configuration of 21, 27, 28, and 29 rotors. The measuring range varies significantly between models, with capacities from as low as 3 mPa.s to as high as 16M mPa.s. This extensive range ensures suitability for a wide array of Newtonian liquids, maintaining an impressive test error of ±3% and a repetitive error of ±1.5%.

Model YR05843 YR05844 YR05845 YR05846
Display liquid-crystal display
Speed (r/min) 0.5/1/2/2.5/4/5/10/15/20/25/30/40/50/60/70/80/90/100 a total of 18 speeds.
Rotor 18,25,31,34 21,27,28,29 (standard configuration)
Measuring range (mPa.s) 3- 1.6M 18rotor:3-10K
25rotor:480-1.6M
31rotor:30-100K
34rotor:60-200K
50 – 2M
21rotor:50-100K
27rotor:250-500K
28rotor:500-1M
29rotor:1K-2M
100 – 4M
21rotor:100-200K
27rotor:500-1M
28rotor:1K-2M
29rotor:2K-4M
400 – 16M
21rotor:400-8M
27rotor:2K-4M
28rotor:4K-8M
29rotor:8K-16M
K = 1,000; M=1,000,000
Test error ±3% (Newtonian liquid)
Repetitive error ±1.5% (Newtonian liquid)
Temperature control range Room temperature plus 10℃-250℃ (300℃ optional)
Temperature control accuracy 0.1℃
Print interface YES

Market Price

The market for high-temperature viscometers is diverse, with prices varying based on features, model specifications, and the included technological advancements. Typically, the High Temperature Viscometer models YR05843 – YR05846 are positioned in the mid-to-high range due to their advanced capabilities and precision engineering. On average, these viscometers can range from $5,000 to $15,000, depending on the supplier and any additional custom features requested. To receive an accurate quote tailored to your needs, we invite potential buyers to utilize the Kalstein Plus platform for an instant price estimation.

Frequently Asked Questions

What materials can these viscometers measure?

These viscometers are designed to measure the viscosity of Newtonian liquids across a wide range of viscosities and temperatures, making them suitable for various industrial and research applications.

What is the temperature control range?

The models have a temperature control range from room temperature plus 10°C to 250°C, with an optional increase to 300°C, allowing for high-temperature applications requiring precise viscosity measurements.

How accurate are the measurements?

The viscometers provide a measurement error margin of ±3% for Newtonian liquids, with a repetitive error margin of ±1.5%, ensuring reliable and consistent results.

Advantages and Disadvantages

Advantages: These viscometers excel in precision and versatility, capable of handling a vast range of viscosity measurements with fine temperature control. Their liquid-crystal display facilitates ease of use, and multiple speed settings enable flexibility across testing protocols.

Disadvantages: Despite their robust capabilities, these devices might require significant upfront investment, and the complexity of operations may necessitate additional training for optimal use.

Usage in the Field

In practical scenarios, the High Temperature Viscometer is indispensable for quality control in industries such as petrochemicals, food processing, and pharmaceuticals. Its ability to maintain consistent temperature and deliver precise viscosity readings makes it a vital tool for ensuring product standards and consistency across batches. Technicians typically utilize the equipment in controlled laboratory environments where accuracy and reliability are paramount.

Recommendations

For optimal operation, it is recommended that users undergo brief training sessions to familiarize themselves with the equipment’s features and capabilities. Regular maintenance checks and calibration against known standards will further enhance the longevity and precision of the viscometer. Utilizing the Kalstein Plus platform allows users to stay updated on product enhancements and supports them in obtaining the best performance from their investment.

If you are seeking a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the most friendly prices. Do not hesitate any longer, we bring science to life, it’s time to become part of our community. https://kalstein.net/en/product/high-temperature-viscometer-yr05843-yr05846/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]