Product Description
The YR06297 BOD Analyzer stands out as an advanced piece of equipment designed to provide precise and reliable measurements of Biochemical Oxygen Demand (BOD) in water quality testing. This model is crucial for laboratories that conduct detailed analyses of environmental samples, as it measures BOD levels ranging from 0-4000 mg/L, ensuring a broad spectrum of application.
The accuracy of this analyzer is noteworthy, meeting stringent standards for water quality BOD5 testing. It adheres to the glucose glutamic acid standard solution BOD5, ranging from 180-230mg/L, making it an essential tool for any laboratory focused on credible results. The test duration is flexible, spanning from 1 to 30 days, and it can handle up to 6 samples simultaneously.
The unit’s recording interval is versatile, offering ranges from 24 minutes to 12 hours per reading, enabling precise monitoring. It can also store a significant amount of data, capable of saving detailed BOD values and biochemical reaction curves of the latest analytical samples. The historical data capability allows for the storage of 20 sets of final test data, making it invaluable for ongoing research and analysis.
| Model | YR06297 |
| Test Range | 0-4000 mg/L |
| Test Error | It meets the accuracy testing standard for water quality BOD5 (glucose glutamic acid standard solution BOD5=180-230mg/L) |
| Test Duration | 1-30 days |
| Test Quantity | 6 pieces |
| Recording Interval | 24 minutes -12 hours/time |
| Storage quantity | Detailed data: Save the BOD values and biochemical reaction curves of the latest set of analytical samples. |
| Historical data: Can save 20 sets of final test data. | |
| Culture flask solvent | 580ml |
| Culture temperature | 20 ±1 °C |
| Wireless print | |
| Power | 110-220V, 50/60Hz |
Market Price
The pricing for the YR06297 BOD Analyzer varies considerably based on the vendor and the included services or add-ons, such as extended warranties or calibration services. Generally, the price range is between $3,000 and $5,000, reflecting the unit’s advanced capabilities and essential role in reliable BOD analysis. For the most competitive pricing, it is recommended to request a quote through the Kalstein Plus platform.
Frequently Asked Questions
What is the primary use of the YR06297 BOD Analyzer?
This analyzer is primarily used for assessing the Biochemical Oxygen Demand in water samples, which is a critical parameter in environmental monitoring and compliance testing.
How many samples can be tested simultaneously with this analyzer?
The YR06297 model can test up to 6 samples at the same time, optimizing laboratory throughput and efficiency.
Is it possible to retrieve historical data from the analyzer?
Yes, the device is equipped to store 20 sets of final test data, allowing for extensive historical data retrieval and analysis.
Advantages and Disadvantages
Advantages: The YR06297 BOD Analyzer boasts high accuracy and a broad test range, making it suitable for a wide array of testing environments. Its capability to store substantial data and wireless printing option adds to its convenience and efficiency. Moreover, its adaptability in recording intervals makes it versatile for varying analytical needs.
Disadvantages: While the analyzer provides advanced features, the initial investment can be significant for smaller laboratories. Furthermore, routine calibration and maintenance need to be considered for optimal performance and accuracy.
Product Use in the Field
The YR06297 BOD Analyzer is used extensively in environmental science labs, wastewater treatment facilities, and research institutions. Its robust design and reliable results make it a preferred choice for professionals aiming for precision in BOD measurement. The ability to conduct tests over durations of up to 30 days allows for extensive and detailed analyses in compliance studies and research.
In practical applications, its wireless printing feature is particularly beneficial, allowing seamless documentation of results for auditing and assessment purposes, aligning well with the needs of remote or field stations constrained by space.
Recommendations
For maximizing the utility of the YR06297 BOD Analyzer, it is crucial to adhere to recommended guidelines for operation and maintenance. Regular calibration through certified standards ensures the accuracy and precision of results. Additionally, maintaining the culture temperature at the specified 20 ±1 °C is essential for consistent results.
It is advisable to utilize the Kalstein Plus platform to request an automated quote, ensuring that you receive the best value and support for your investment. With their extensive catalog and customer-friendly purchase channels, Kalstein ensures your laboratory is equipped for success.
If you are seeking a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a high level of excellence. Our intuitive and agile online shopping channels are designed for your convenience, ensuring the most customer-friendly prices. Do not hesitate any longer, we bring science to life, it is time to become part of our community. https://kalstein.net/en/product/bod-analyzer-yr06297/.