Innovative Infant Incubator YR02186: Technical Excellence and Key Features

Product Description

The Infant Incubator Model YR02186 is designed to provide a safe and controlled environment for newborns requiring specialized care. This state-of-the-art equipment is equipped to maintain optimal temperatures and ensures consistent monitoring of the infant’s environment. With an electrical requirement of approximately ~220V 59Hz or ~230V 60Hz and a power consumption of ≤450VA, the incubator offers reliable and efficient operation.

The device boasts a sophisticated air mode temperature range from 25.0°C to 37.0°C and a skin mode temperature range that matches it. In situations where higher temperature settings are necessary, the air mode can be adjusted between 37.1°C and 39.0°C, while the skin mode ranges up to 38.0°C, providing flexibility and responsiveness to the needs of the infant patient. Safety is prioritized with alarms set for high temperature modes below 40.0°C and both air and skin mode fluctuations are promptly addressed with adjustable alarm limits of ±3.0°C and ±1.0°C respectively.

Model YR02186
Electrical requirement ~220V 59Hz or ~230V 60Hz
Power consumption ≤450VA
Air mode temperature range 25.0°С~37.0°C
Skin mode temperature range 25.0°C~37.0°C
Air over temperature range <38.0°C
Air mode high temperature range 37.1°C~39.0°C
Skin mode high temperature range 37.1°C~38.0°C
High temperature mode alarm < 40.0°C
Air mode alarm ±3.0°C
Skin mode alarm ±1.0°C
Skin sensor accuracy ≤±3.0°C
Air control accuracy ≤0.5°C
Mattress temperature uniformity ≤0.8°C
Noise ≤55dB (A)

Market Price

The Infant Incubator Model YR02186 generally falls within a premium range due to its advanced features and technological prowess. While exact pricing can vary based on supplier, location, and additional service options, you can expect it to be within the range of $3,000 to $5,000. For the most accurate and competitive pricing, consider requesting a quotation directly through the Kalstein Plus platform.

Frequently Asked Questions

What kind of power supply does the YR02186 require?

The incubator requires an electrical supply of ~220V 59Hz or ~230V 60Hz.

How does the temperature alarm system work?

The device is equipped with alarms that trigger if temperatures deviate from the set range – air temperature alarms are set at ±3.0°C, while skin mode alarms are more sensitive at ±1.0°C.

Can the YR02186 be used in all healthcare settings?

Yes, the YR02186 is designed to be adaptable for various healthcare environments, from intensive neonatal units to hospital maternity wards.

Advantages and Disadvantages

Advantages: The YR02186 model features a precise temperature regulation system with an air control accuracy of ≤0.5°C and superior mattress temperature uniformity of ≤0.8°C, ensuring the infant’s environment is consistently optimal. Additionally, it operates at noise levels of ≤55dB (A), which is essential for maintaining a calm and quiet environment conducive to newborn health.

Disadvantages: The premium technology in the YR02186 might not be necessary for all healthcare facilities, particularly smaller clinics with lower birth rates. Additionally, its cost could be a barrier for institutions with limited budgets unless substantial financing or leasing options are available.

Use of Product in the Field

The YR02186 Infant Incubator is primarily utilized in neonatal intensive care units to support preterm or critically ill infants who require controlled environmental conditions. Its advanced features are aimed at simulating the womb environment, thereby facilitating the infant’s adaptation to life outside the uterus. The incubator is also a critical component in transporting infants requiring intensive care, ensuring stability during transit between departments within a healthcare facility.

The device is engineered for ease of use, allowing healthcare providers to make swift adjustments to settings in response to the infant’s needs. Its robust sensor system continuously monitors and displays the infant’s body temperature, providing a reliable guide for clinicians to act promptly when necessary.

Recommendations

To maximize the utility of the YR02186, it is recommended that the staff is adequately trained in both the technical and procedural aspects of its operation. Routine maintenance should be performed to ensure continued reliability and functionality. Regular calibration of the temperature controls is crucial to guarantee that the readings remain accurate and that the infants are kept in a stable environment.

We also recommend integrating the incubator into a broader neonatal care system, where it can operate in conjunction with other monitoring and support equipment. This will provide a comprehensive care package for neonatal patients. Given its critical role, consider implementing a robust emergency power backup strategy to ensure uninterrupted service during power outages.

If you’re searching for a fusion of innovation and quality, you’ve come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the friendliest prices. Wait no more, we bring science to life, it’s time to be part of our community.
https://kalstein.net/en/product/infant-incubator-yr02186/

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]