State-of-the-Art Infant Incubator YR02187: Technical Features and Market Insights

Product Description

The Infant Incubator YR02187 represents a cutting-edge advancement in neonatal care technology, combining precision, safety, and ease of use. **Its LCD display** provides a user-friendly interface, offering seamless interaction for healthcare professionals. Despite its sophisticated capabilities, the incubator is energy-efficient with a power consumption of **≤550VA**, ensuring quality care without compromising energy usage. The electrical requirements are flexible, with options for ~220V 50Hz or ~230V 60Hz, catering to various international standards.

Precision is further enhanced through **dual-mode temperature control**, allowing the selection between air and skin modes. Both these modes operate within a temperature range of 25.0°C to 37.0°C, ensuring the infant is kept under ideal conditions. When necessary, high-temperature settings can be employed, where the air mode can reach up to 39.0°C, while the skin mode supports a range up to 38.0°C. Safety alarms are integrated, alerting medical staff if temperatures deviate significantly from the set range.

To support the delicate needs of newborns, **humidity control** is adjustable from 30% RH to 90% RH, ensuring a moist and nurturing environment. Additionally, the incubator provides an optional oxygen control ranging from 20%-60% with a display accuracy of ±3%. The integrated noise levels are kept at a minimum, registering at ≤55dB(A), to maintain a tranquil atmosphere for rest and recovery.

Model YR02187
Display LCD
Electrical requirement ~220V 50Hz or ~230V 60Hz
Power consumption ≤550VA
Air mode temperature range 25.0°C~37.0°С
Skin mode temperature range 25.0°C~37.0°C
Air over temperature range <38.0°C
Air mode high temperature range 37.1°C~39.0°C
Skin mode high temperature range 37.1°C~38.0°C
High temperature mode alarm < 40.0°C
Air mode alarm ±3.0°C
Skin mode alarm ±1.0°C
Skin sensor accuracy ≤±3.0°C
Air control accuracy ≤0.5°C
Mattress temperature uniformity <0.8°C
Humidity control range 30%RH-90%RH
O2 control range (option) 20%-60%
O2 display accuracy (option) ±3%
Electrical scale weight range (option) 0.1kg-8.0kg
Electrical scale display range (option) ±50g
Noise ≤55dB(A)

Market Price

The price of the Infant Incubator YR02187 varies depending on geographical location, supply chain logistics, and specific models with optional features. Generally, the price range can be anticipated between $2,500 to $7,000, depending on configuration and additional features. You can request a quote to gain accurate pricing tailored to your needs, ensuring you make an informed and economical decision. Take advantage of the automatic quotation feature via the Kalstein Plus platform, and explore the perfect incubator fit for your requirements.

Frequently Asked Questions

What type of display does the incubator use?

The incubator features an LCD display, offering clear visibility and ease of use.

What is the power consumption of the incubator?

The incubator has a power consumption of ≤550VA.

Is the oxygen control range optional?

Yes, the oxygen control range of 20%-60% is an optional feature.

Advantages and Disadvantages

The Infant Incubator YR02187 offers several advantages, including its ability to create a highly controlled and safe environment for neonates. The precision in temperature and humidity control ensures that infants receive optimal care. The minimal noise levels are essential for maintaining a peaceful environment conducive to recovery.

However, potential disadvantages may include the initial financial investment required and the operational learning curve for new users. Despite these factors, the incubator’s benefits in enhancing neonatal care and recovery typically offset these initial inconveniences.

Field Usage

The incubator is an indispensable tool within neonatal intensive care units, providing crucial support to premature and critically ill infants. By maintaining controlled temperature and humidity levels, the incubator facilitates ideal conditions for growth and development that might be compromised outside this technology.

In practical scenarios, medical personnel can adjust settings easily through the LCD interface, ensuring the infant’s environment responds dynamically to changing needs. With optional features tailored to specific clinical requirements, the YR02187 stands out as a versatile instrument in any pediatric setting.

Recommendations

To maximize the incubator’s efficiency, regular maintenance should be conducted, focusing on calibration and hygiene to prevent any microbial contamination. Familiarity with the user interface will allow clinicians to optimize temperature and humidity settings effectively. Additionally, consider the optional features like oxygen control for specialized neonatal care scenarios, available through Kalstein’s customizable purchasing options.

If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece with a level of excellence. Our intuitive and flexible online buying channels are designed for your convenience, ensuring the most friendly prices. Don’t hesitate any longer, we bring science to life, it’s time to become part of our community. https://kalstein.net/en/product/infant-incubator-yr02187/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]