Advanced Features of the Multifunctional Imager YR06067 and YR06068

Product Description

The Multifunctional Imager models YR06067 and YR06068 are top-tier imaging systems designed for scientific applications requiring precision and clarity. Both models are equipped with a cooled CCD digital camera, offering a physical resolution of 6 Megapixels (2750×2200). These configurations ensure that users capture high-quality images for detailed analysis.

One of the standout features of these models is their exceptional pixel density and A/D capabilities, boasting 16-bit processing. This provides an in-depth grey scale level of 65,536, delivering a dynamic range of ≥4.6OD. Such specifications make these imagers indispensable for laboratories focusing on meticulous image analysis.

The cooling temperature capability is another aspect where these models shine, maintaining -60℃ below ambient and -30℃ regulated. This ensures optimal performance under various lab conditions. The scientific lens differs slightly: while the YR06067 comes with a Sensitive F0.95 Lens, the YR06068 includes an Ultra sensitive F0.8 Lens, catering to different levels of sensitivity required by the user. The imagers also feature a four-layer chemiluminescence sample tray, UV transmission range of 302nm-312nm, and a 21x26cm UV area, making them versatile for various sample types.

Model YR06067 YR06068
Digital Camera Cooled CCD Camera
Physical Resolution 6 Megapixels,2750*2200
Pixel Density and A/D 16 Bit
Grey Scales 65536
Dynamic Range ≥4.6OD
Cooling Temperature -60℃ below ambient, -30℃ regulated
Scientific Lens (Difference between both models) Sensitive F0.95 Lens Ultra sensitive F0.8 Lens
Chemiluminescence sample tray 4 Layer
UV Transmission 302nm-312nm, area:21x26cm
White LED Transmission Area: 19x26cm
Filter Wheel Five position
Filter Gel Doc Filter
UV Protection UV Protection Shield
Image Acquisition Software No software dongle required, unlimited users, free update
Image Analysis Software No software dongle required, unlimited users, free update

Market Price

The Multifunctional Imager’s price range varies based on market factors, but typically, these state-of-the-art devices are found in the range of $24,700 to $25,500 USD. The pricing reflects the advanced technology and capabilities embedded within the YR06067 and YR06068 models. For labs looking for precision and high performance, this investment is well worth it, especially considering the comprehensive imaging features and applications.

The pricing can vary depending on distributors and any additional service packages. It’s recommended to contact authorized Kalstein representatives to get precise pricing details and explore potential discounts. This allows laboratories to budget effectively and ensure they gain maximum value from their investment in these molecular imaging devices.

Frequently Asked Questions

What are the main differences between YR06067 and YR06068?

The primary difference lies in the lens; the YR06067 model uses a Sensitive F0.95 Lens, while the YR06068 is equipped with an Ultra sensitive F0.8 Lens.

What is the cooling temperature capability?

Both models feature a cooling capability of up to -60℃ below ambient, with a regulated temperature of -30℃ for enhanced performance.

Is a software dongle required?

No, the software for image acquisition and analysis does not require a dongle. Users benefit from unlimited access and free updates, streamlining operations.

Advantages and Disadvantages

Advantages: The YR06067 and YR06068 offer high image resolution and a dynamic range that supports detailed scientific analysis. With a comprehensive cooling system, these systems maintain performance in various environments, while the software is nimble and user-friendly. The multi-position filter wheel is adaptable for diverse imaging needs.

Disadvantages: As with high-end imaging equipment, the cost may be prohibitive for smaller laboratories. Additionally, the initial setup requires expertise to maximize the use of these instruments, potentially necessitating additional training for staff.

Field Application

The YR06067 and YR06068 are utilized in advanced scientific research and clinical labs focused on molecular biology, genetics, and chemiluminescence studies. Their excellent resolution and dynamic range make them ideal for detecting subtle variations in samples, critical in precise research applications.

These imagers are especially advantageous in environments where low-light detection is essential, ensuring the integrity of sensitive samples. Their robust construction and UV protection features provide safety for repeated lab utilization.

Recommendations

To fully leverage the benefits of the YR06067 and YR06068, users should ensure regular maintenance checks to uphold imaging quality. Additionally, staying updated with the latest software upgrades from Kalstein guarantees enhanced features and stability.

Implementing a training program for laboratory staff is advisable, focusing on safe handling and operation. Engaging with Kalstein’s online resources and support networks can offer valuable insights into maximizing productivity and achieving accurate results.

If you are seeking a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online shopping channels are designed for your convenience, ensuring the friendliest prices. Don’t hesitate any longer, we bring science to life, it’s time to become part of our community. https://kalstein.net/en/product/multifunctional-imager-yr06067-yr06068/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]