Innovative Microplate ELISA Reader YR05128: Precision Meets Efficiency

Product Description

The Microplate ELISA Reader YR05128 is a state-of-the-art laboratory device designed to deliver precise and reliable absorbance readings across a wide range of applications. Built for research labs, pharmaceutical companies, and clinical environments, the YR05128 model is especially noted for its robustness and advanced technological features. Measuring absorbance in the range of 0 – 4.000Abs, this reader ensures high-resolution outcomes with a displayed resolution of 0.001 Abs and a calculated resolution of 0.0001 Abs, offering the precision that today’s scientific research demands.

The device incorporates a 6V/19W halogen lamp as its light source, paired with an 8-channel optical fiber system, enhancing measurement accuracy and consistency. It operates on four standard filters—wavelengths of 405 nm, 450 nm, 492 nm, and 630 nm—while also allowing the integration of three additional optional filters, making it versatile for various research needs. With a wavelength accuracy of 2 nm and a bandwidth of 8 nm, the YR05128 stands out for its reliability and detail-oriented performance.

Designed with user convenience in mind, this microplate reader supports several calculation methodologies including ABS, cut, multipercentage, percentile registry, linear, exponential, index, and regression 4PL, among others. It supports endpoint, fixed time, and kinetics methodologies, making it adaptable to diverse experimental setups. Capable of handling a standard 96-well microplate—or other microplate types and strips—it offers rapid reading speeds, processing a 96-well plate in just 5 seconds per wavelength.

Model YR05128
Absorbance range 0 – 4.000Abs
Resolution 0.001 Abs (displayed), 0.0001 Abs (calculated)
Light source 6V/19W halogen lamp
Optical system 8-channel optical fiber system
Lengths 4 standard filters wave: 405 nm, 450 nm, 492 nm, 630 nm, 3 additional optional filters
Wavelength accuracy 2 nm
Bandwidth 8 nm
Calculation method ABS, cut, multipercentage, percentile registry, linear, Exponential, Index, Regression 4PL, etc.
Methodologies Endpoint, Fixed time, Kinetics
Type Standard microplate with 96 wells or other types of microplate and strip
Reading speed 5 seconds for a 96-well plate (single-wavelength)
Memory Storage for up to 100 programs and 10,000 sample results
Printer Internal thermal printer, optional external printer
Dimensions (mm) 425 (length) x 310 (width) x 215 (height)
Weight 12kg

Market Price

In the competitive market of laboratory equipment, the Microplate ELISA Reader YR05128 stands out not only for its features but also for its competitive pricing. Typically priced between $2500 USD and $3300 USD, it offers excellent value given its high precision, rapid processing speed, and versatile functionality. When compared to similar instruments within its class, the YR05128 presents a cost-effective solution without compromising on technological advancements or performance.

For laboratories seeking cost-saving yet high-performing devices, this microplate reader is an ideal choice. The advantageous price range reflects its well-balanced load of features, offering laboratories substantial savings and ensuring budget-friendly operations. Laboratories worldwide find the YR05128 not only a worthy investment but a pivotal addition to their research and analysis toolkit.

Frequently Asked Questions

What are the main applications of the YR05128 Microplate ELISA Reader?

The YR05128 is primarily used for measuring absorbance in ELISA assays, suitable for research labs, clinical testing environments, and quality control processes in pharmaceutical settings.

Can I install additional filters on the device?

Yes, besides the four pre-installed standard filters, the YR05128 supports the integration of three additional optional filters, offering more flexibility for various experimental demands.

What kind of data storage does the reader support?

The reader includes memory capacity for storing up to 100 programs and 10,000 sample results, facilitating workflow management and data retrieval.

Advantages and Disadvantages

The Microplate ELISA Reader YR05128 offers several advantages that make it an attractive option for laboratories. One of its key strengths is its high-resolution capability and broad absorbance range, which allow precise measurements. The rapid processing time for a 96-well plate and extensive calculation methods further enhance its efficiency and adaptability. Moreover, its compact design and reasonable weight make it easy to integrate into various lab setups.

However, potential users should be aware of some considerations before making a purchase. The reliance on a halogen lamp, though effective, does require periodic replacement, which may incur additional costs over time. Additionally, while the standard filter options are comprehensive, laboratories with unique wavelength needs must ensure the optional filter compatibility aligns with their tasks.

Product Use in the Field

In real-world applications, the YR05128 demonstrates exceptional versatility and reliability. Commonly used in enzyme-linked immunosorbent assays, the reader’s precision aids in accurately quantifying protein concentrations, crucial in diagnostics and research. Its robust design supports heavy usage in high-volume labs, where ease of use and rapid results are prized.

Many clinical laboratories employ the device for diagnostic purposes, including hormone, allergen, and infectious disease detection, owing to its efficient throughput and detailed data analysis capabilities. Pharmaceutical companies often leverage its precision and calculation methods for drug concentration analysis and stability testing, maximizing research accuracy and product development efficiency.

Recommendations

To maximize the Microplate ELISA Reader YR05128’s performance and extend its lifespan, routine maintenance is essential. Regularly check and replace the halogen lamp to ensure consistent light output and accurate readings. Additionally, software updates should be performed to keep the device operating optimally, benefitting from the latest enhancements.

Ensure proper calibration of the optical system, and periodically verify the accuracy of standard and optional filters. Proper training for laboratory staff on the device’s functionalities will foster efficient and accurate usage, reducing potential user-error and improving overall laboratory efficiency.

If you are looking for a fusion of innovation and quality, you’ve come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece with a level of excellence. Our intuitive and agile online shopping channels are designed for your convenience, ensuring the most friendly prices. Don’t hesitate any longer, we bring science to life—it’s time to become part of our community. https://kalstein.net/en/product/microplate-elisa-reader-yr05128/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]