Product Description
The Tabletop Autoclave Class B from Kalstein represents a significant leap in sterilization technology, offering a blend of efficiency and reliability that meets the needs of modern laboratories. Available in four models—YR03387, YR03388, YR03389, and YR03390—this autoclave series caters to a range of sterilization volumes, from 8 to 23 liters. This variety ensures that whether you’re working in a small clinic or a large research facility, there’s an option to suit your precise needs.
Each model is engineered with robust materials, featuring chambers that range from Ø170×320 mm to Ø247×450 mm. The number of trays varies with each model, with YR03387 and YR03388 supporting up to three trays made of either aluminum or stainless steel, and YR03389 and YR03390 accommodating up to five aluminum trays. Operating at 220/110V and a frequency of 50/60Hz, the power consumption varies slightly between models, reaching a maximum of 2200W for the YR03390.
| Model Number | YR03387 | YR03388 | YR03389 | YR03390 |
| Chamber Dimension | Ø170×320 mm | Ø200×360 mm | Ø247×350 mm | Ø247×450 mm |
| Chamber Volume | 8 L | 12 L | 18 L | 23 L |
| Number of Trays | 2/ Max. 3 | 2/ Max. 3 | 3/ Max. 5 | 3/ Max. 5 |
| Material of Trays | Aluminum | Stainless Steel | Aluminum | Aluminum |
| Size of Trays | 130x265mm | 156x295mm | 192x285mm | 192x380mm |
| Voltage Freq. | 220/110V | 220/110V | 220/110V | 220/110V |
| 50/60Hz | 50/60Hz | 50/60Hz | 50/60Hz | |
| POWER | 2000W | 2000W | 2000W | 2200W |
| Overall Dimension (WxHxD) | 420x370x525 mm | 420x370x595 mm | 490x455x600 mm | 490x455x690 mm |
| Weight | 37 kgs | 40 kgs | 47 kgs | 53 kgs |
Market Price
Understanding the cost dynamics in the sterilization equipment market is crucial for budgeting and procurement planning. While the exact price of the Tabletop Autoclave Class B is $2,280, prospective purchasers can expect to find similar models ranging from $2,200 to approximately $3,000. This range provides insight into competitive pricing and helps institutions make informed purchasing decisions based on financial and operational needs.
The variation in price often accounts for differences in the chamber volume, tray material, and associated technological advancements, which can be critical in fulfilling specific laboratory requirements. For tailored price information and quotations, we encourage users to explore the Kalstein Plus platform for personalized pricing solutions.
Frequently Asked Questions
What is the sterilization cycle duration?
The sterilization cycle of the Tabletop Autoclave Class B varies depending on the load and program selected, typically ranging from 20 to 60 minutes per cycle. The precise timing ensures high levels of sterilization efficiency, crucial for maintaining laboratory standards.
Is this autoclave suitable for all laboratory environments?
Yes, the autoclave’s compact design and varying chamber sizes make it adaptable for use in diverse laboratory settings, from medical clinics to research facilities. Its versatile nature makes it a preferred choice across numerous scientific and medical fields.
What kind of maintenance does the autoclave require?
Regular cleaning of the chamber and trays is essential, along with annual professional inspections to ensure all mechanical and electronic components function optimally. Proper maintenance enhances the longevity and performance of the autoclave.
Advantages and Disadvantages
One of the primary advantages of the Tabletop Autoclave Class B is its flexibility in accommodating different sterilization needs, backed by its user-friendly interface and advanced safety features. Its compact form factor allows it to be placed conveniently in most laboratory environments without occupying excessive space.
However, initial setup may require detailed understanding, especially for first-time users, which can be mitigated by the comprehensive user manual and customer support provided. Additionally, higher power consumption could be a consideration for budget-conscious operations, but the benefits often outweigh this, given its efficiency and reliability.
Usage in the Field
The Tabletop Autoclave Class B is predominantly used in both clinical and research environments where sterilization of instruments and materials is critical. It is particularly favored in medical and dental settings for its ability to sterilize different types of instruments swiftly and effectively.
Moreover, its versatility extends to research labs where the precision and speed of sterilization cycles contribute significantly to the workflow. The autoclave’s design ensures that sensitive instruments are sterilized thoroughly without compromising their integrity, a crucial aspect in preserving the longevity and accuracy of laboratory equipment.
Recommendations
To maximize the utility of the Tabletop Autoclave Class B, it is recommended to consistently follow the manufacturer’s guidelines on load capacity and cycle selection. Avoiding overloading can significantly enhance the sterilization quality while prolonging the equipment’s lifespan.
In addition, incorporating regular maintenance routines, such as descaling and routine cleaning, can prevent common issues associated with autoclaves, such as chamber scaling and tray wear. Opt for the Kalstein Plus platform for expert guidance and tailored maintenance services.
If you’re seeking a fusion of innovation and quality, you’ve come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive laboratory equipment catalog. We manufacture each device with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the friendliest prices. Don’t hesitate any longer; we bring science to life; it’s time to become part of our community. Explore the Tabletop Autoclave here.