Vertical Air Supply Clean Bench YR05733: Superior Laboratory Equipment

Product Description

The Vertical Air Supply Clean Bench YR05733 excels in creating a controlled, contamination-free environment for laboratory operations. Engineered with precision, this model offers a vertical air supply system, ensuring optimal cleanliness and safety for various sensitive applications. The clean bench maintains a cleanliness level of Class 100@≥0.5μM according to the US Federal 209E standard, significantly reducing the risk of contamination.

This cutting-edge equipment supports rigorous laboratory requirements with a colony count of ≤0.5 pcs/dish·hour using a Φ90mm culture plate. It offers an adjustable average wind speed from 0.25 to 0.45 m/s, which can be adjusted between fast and slow modes depending on your specific needs. Moreover, the noise level does not exceed 62 dB(A), ensuring a quiet working environment.

Specification Detail
Model YR05733
Air Supply Vertical Air Supply
Cleanliness level Class 100@≥0.5μM (US Federal 209E)
Number of colonies ≤0.5pcs/dish·hour (Φ90mm culture plate)
Average Wind Speed 0.25~0.45m/s (Fast and slow)
Noise ≤62dB(A)
Vibration half peak ≤5μM (x, y, z direction)
Illuminance ≥300Lx
Power Supply AC single-phase 220V/50Hz
Max. Power Consumption 800 W
Working area
W1×D1×H1
1140 x 580 x 700
Overall dimension
W×D×H
1300 x 760 x 1760
Specification and quantity of high efficiency filter 1125 x 540 x 50 x 1
Specification and quantity of fluorescent lamp/ultraviolet lamp 20W x 1 / 36W x 1
Applicable Persons Double person-single side

Market Price

Understanding the current market for vertical air supply clean benches is crucial for making an informed purchase. The YR05733 model typically falls within the price range of $2600 to $3450, depending on additional features and services offered. This attractive pricing assures laboratories of investing in a cost-effective, high-performance unit that aligns with their operational budgets.

Frequently Asked Questions

How often should the filters be changed in the YR05733 model?

It is recommended to check and replace the filters every six months to ensure optimal operation and air quality. However, this can depend on the specific environment and usage frequency.

Is the Vertical Air Supply Clean Bench difficult to install?

No, the YR05733 model is designed for easy installation, following the detailed manual provided. Kalstein’s customer support can provide additional guidance if needed.

Can this clean bench accommodate two people working simultaneously?

Yes, it is designed for double person-single side use, accommodating two users effectively while maintaining the cleanliness standards required.

Advantages and Disadvantages

The Vertical Air Supply Clean Bench YR05733 presents numerous advantages, including its superior air filtration system that adheres to high cleanliness levels and its ergonomic design providing comfort during extended use. Additionally, the low noise and vibration levels ensure minimal disturbances, crucial for precision work.

A potential disadvantage might be the need for regular maintenance to preserve its high performance levels, which could be considered an operational cost. Ensuring timely filter replacements and routine checks are integral to maintaining its efficacy.

Usage in the Field

The YR05733 is versatile, used across various fields such as pharmaceuticals, electronics, and medical research. Its robust features are particularly beneficial in environments where contamination control is paramount. The clean bench’s timely air supply and efficient filtration make it ideal for critical operations such as sample preparation and component assembly.

Laboratories benefit from its reliable performance in maintaining product integrity by ensuring zero contamination in sensitive procedures. Such attributes make it an indispensable tool in facilitating accurate and reliable laboratory work.

Recommendations

To maximize the lifespan and efficiency of the YR05733 clean bench, it is essential to follow a thorough maintenance schedule. Regularly check the air filters, ensuring they are free of debris and replacing them when necessary. Calibrate the airflow speed to meet specific operational requirements effectively without compromising on energy efficiency.

Additionally, users should follow proper protocols during operation to prevent unnecessary wear and tear. This includes running the unit in a stable environment, away from direct airflow or sharp temperature changes that might affect performance.

If you are seeking a blend of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, guaranteeing the friendliest prices. Do not hesitate any longer, we bring science to life; it’s time to be part of our community. https://kalstein.net/en/product/horizontal-air-supply-clean-bench-yr05733/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]