Product Description
The Orbital Shaker models YR05766, YR05767, and YR05768 stand out as versatile and essential tools for laboratories, facilitating various mixing processes efficiently. These shakers are designed with state-of-the-art technology to deliver consistent and reliable results, making them indispensable in any experimental setup.
Each model offers distinct shaking modes to cater to unique laboratory requirements. The YR05766 features a dual-mode capable of orbital and convolution shaking. Meanwhile, the YR05767 provides a rocking shaking mode, and the YR05768 excels in wavina and three-dimensional shaking. All models are equipped with a Microcomputer PID control for precise operation and an LED digital display for easy monitoring of parameters.
Amplitudes vary among models, with the YR05766 depicting a 30mm diameter, the YR05767 offering a 25mm amplitude, and the YR05768 facilitating manual adjustments from 3 to 15 degrees. The frequency range varies as well; YR05766 operates between 15-240 rpm/min, while YR05767 and YR05768 run from 15-90 rpm/min. Additionally, the YR05766, YR05767, and YR05768 offer a sensitivity margin of ±2 rpm, ensuring precise control.
| Model | YR05766 | YR05767 | YR05768 |
| Shaking Mode | orbital/ convolution | rocking | wavina / three dimensional |
| Control | Microcomputer PID control | ||
| Display | LED digital display | ||
| Amplitude | Ø30 | 25mm | 3-15°(manual) |
| Frequency (rpm/min) | 15-240 | 15-90 | |
| Sensitivity (rpm) | ±2 | ||
| Timer | 0-99hours59minutes | ||
| Tray Size (mm) | 320×265 | ||
| Tray Number | 1 | ||
| Overall Size (mm) | 330x480x160 | 330x480x220 | 330x480x180 |
| Power | 30W | ||
| Power Supply | AC 90-260V, 50-60HZ | ||
| Ambient Temperature | -10 °C-65 °C | ||
Market Price
Orbital Shakers in the market typically range from 500 USD to 800 USD, depending on the features and brand reputation. The competitive pricing of these models ensures they offer excellent value, delivering high-quality performance without breaking the budget.
Frequently Asked Questions
What is the primary use of an orbital shaker?
Orbital shakers are primarily used in laboratories for the agitation and mixing of samples within flasks, beakers, or tubes. They efficiently mix liquids and solutions to ensure uniform distribution.
Are these models suitable for temperature-sensitive experiments?
Yes, these models can operate within a wide ambient temperature range of -10 °C to 65 °C, making them suitable for diverse experimental conditions.
Can I manually adjust the shaking amplitude on these models?
The YR05768 model offers a manual adjustment of the shaking amplitude between 3 to 15 degrees, providing flexibility for specific requirements.
Advantages and Disadvantages
The Orbital Shakers offer several advantages, including state-of-the-art control through Microcomputer PID technology, ensuring accurate and consistent operation. Additionally, the LED digital display provides clear visibility of operating parameters, and their versatility in shaking modes makes them adaptable to a variety of laboratory applications.
However, potential disadvantages might include the need for routine maintenance to ensure longevity and optimal performance. Users must be familiar with setting the appropriate shaking conditions to avoid compromising experimental results.
Product Use in the Field
The Orbital Shaker models YR05766, YR05767, and YR05768 are integral in fields such as biology, chemistry, and medical research. They are used extensively for culturing cells, dissolving solutes, and conducting hybridization experiments. Their precise control and robust design make them suitable for high-demand laboratory environments.
In practical scenarios, researchers benefit from these shakers’ ability to provide consistent shaking speeds and amplitudes, crucial for results reproducibility and experimental precision.
Recommendations
To maximize the efficiency and lifespan of your orbital shaker, it is recommended to regularly calibrate and maintain the equipment according to the manufacturer’s guidelines. Ensure the correct power supply is connected, and avoid overloading the tray during operations.
For optimal results, users should regularly check the calibration and ensure that the shakers are operating within the specified temperature range. Consistent cleaning and careful sample placement can prevent equipment downtime and enhance performance.
If you are considering purchasing a versatile and reliable orbital shaker, we encourage you to request a quote or generate an automatic quote through the Kalstein Plus platform. Experience cutting-edge innovation and elevate your research capabilities today.
If you’re looking for a blend of innovation and quality, you’ve come to the right place. At Kalstein we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the friendliest prices. Don’t hesitate any longer. We bring science to life; it’s time to become part of our community. https://kalstein.net/en/product/orbital-shaker-yr05766-yr05768/.