Product Description
The Multifunctional Imager models YR06067 and YR06068 are at the forefront of scientific imaging technology. These devices are equipped with a cooled CCD camera that ensures optimal image quality with a physical resolution of 6 megapixels (2750×2200), offering researchers unprecedented clarity and detail in their images. The pixel density of 16-bit coupled with 65536 gray scales enables high precision in capturing dynamic data, essential for thorough scientific analysis.
One of the remarkable features differentiating these models is the lens sensitivity, where YR06067 incorporates a sensitive F0.95 lens, while YR06068 boasts an ultra-sensitive F0.8 lens. Such specification provides users with the flexibility to choose based on their imaging needs. Both models ensure superior detection with their dynamic range of ≥4.6OD and a regulated cooling temperature of -60℃ below ambient, effectively maintaining superior thermal stability.
| Model | YR06067 | YR06068 |
| Digital Camera | Cooled CCD Camera | |
| Physical Resolution | 6 Megapixels, 2750*2200 | |
| Pixel Density and A/D | 16 Bit | |
| Grey Scales | 65536 | |
| Dynamic Range | ≥4.6OD | |
| Cooling Temperature | -60℃ below ambient, -30℃ regulated | |
| Scientific Lens (Difference between both models) | Sensitive F0.95 Lens | Ultra sensitive F0.8 Lens |
| Chemiluminescence Sample Tray | 4 Layer | |
| UV Transmission | 302nm-312nm, area:21x26cm | |
| White LED Transmission | Area: 19x26cm | |
| Filter Wheel | Five position | |
| Filter | Gel Doc Filter | |
| UV Protection | UV Protection Shield | |
| Image Acquisition Software | No software dongle required, unlimited users, free update | |
| Image Analysis Software | No software dongle required, unlimited users, free update | |
Market Price
Given the sophisticated capabilities and cutting-edge technology of the YR06067 and YR06068 models, these devices typically range in the market from approximately $24,000 to $25,500 USD. This pricing reflects their robust feature set and the value they offer to scientific imaging, making them a popular choice among research facilities and laboratories looking for reliable and advanced imaging solutions.
Frequently Asked Questions
What applications are these imagers best suited for?
The Multifunctional Imager YR06067 and YR06068 are ideal for applications requiring high resolution and thermal stability, such as chemiluminescence and fluorescence imaging in biological and chemical research.
Are software updates free and how often are they provided?
Yes, the image acquisition software provided with these devices includes free updates. These updates are released periodically to enhance features and fix any technical issues.
Advantages and Disadvantages
Advantages: The key advantages of these imagers include their high-resolution capabilities, excellent cooling system ensuring stable performance, and user-friendly software that does not necessitate additional payments for updates. These features make them exceptionally reliable for various research purposes.
Disadvantages: One potential drawback could be the initial investment cost. However, considering their extensive feature set and advanced technology, the investment is justified for laboratories that prioritize precision and quality in imaging tasks.
Product Use in the Field
These imaging devices are primarily used in research laboratories to capture detailed images of samples in bio-imaging and chemiluminescence. The multi-layer chemiluminescence sample tray supports a wide range of sample types, offering flexibility to scientists in diagnostic procedures and experimental research. The ability to maintain a dynamic range and reliable UV transmission ensures the accuracy and reliability of results.
In practical scenarios, researchers appreciate the straightforward operation thanks to the intuitive software interface, enabling them to focus more on their research outcomes than on managing complex device settings. The protection and quality of the imagery captured are essential in fields such as microbiology, pathology, and pharmaceutical research where precision is critical.
Recommendations
To fully capitalize on the functionalities of the YR06067 and YR06068 models, laboratory technicians should be trained on using the software efficiently. Routine maintenance checks and ensuring appropriate working environments can prolong the device’s lifespan. Furthermore, utilizing the built-in imaging software extensively will enhance user efficiency, providing seamless integration with existing research workflows.
For laboratories aiming to augment their imaging capabilities, exploring financing options or grants can alleviate the initial investment pressures. These models represent a robust long-term investment for any sophisticated laboratory setup.
If you are seeking a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the most user-friendly prices. Don’t hesitate any longer, we bring science to life; it’s time to be part of our community. https://kalstein.net/en/product/multifunctional-imager-yr06067-yr06068/.