Infrared Sterilizers: Optimal Performance with Cutting-Edge Technology

Description of the Product

The YR06040 and YR06041 infrared sterilizers are excellent choices for laboratories requiring efficient and robust sterilization solutions. Characterized by their high-performance capabilities, these models come with distinct specifications catering to diverse needs. Operating at dual power options, 110V/220V, the YR06040 offers a power of 150W while the YR06041 escalates it to 240W.

Both models deliver a central high-temperature setting of 825℃ ± 50℃, providing consistent sterilization. The standby constant temperature operates efficiently with two heating gears of 400℃ and 850℃, ensuring versatility in temperature control. The diameters for sterilization differ between models, with the YR06040 accommodating goods up to φ 14mm, while the YR06041 supports up to φ 35mm. These sterilizers are compact, with the YR06040 offering a length of 150mm and the YR06041 enhancing space efficiency with 100mm.

Model YR06040 YR06041
Power 110V/220V;150W 110V/220V;240W
The Center High-Temperature 825℃ ± 50℃
Standby Constant Temperature Heating with two gears 400℃ / 850℃
The Max-Diameter Of Sterilizer Goods φ 14mm φ 35mm
The Length Of Sterilizer 150mm 100mm
Heating Time 10min
Working Condition Temperature 5 ~ 40℃
Relative Humidity ≤90%
Dimensions 175*130*185mm 147*130*200mm
Net Weight 1.3kg 1.4kg

Market Price

When it comes to investing in laboratory equipment, understanding market dynamics is crucial. The infrared sterilizers YR06040 and YR06041 are nestled within a competitive price range, typically between $200 to $650. Although the specifics of these prices may vary, potential buyers can expect to enjoy a blend of efficiency and cost-effectiveness. It’s noteworthy that Kalstein offers special pricing arrangements for those seeking high-quality semiconductor sterilization capabilities, making them a go-to supplier. Interested buyers are encouraged to request a quotation to explore this financially advantageous opportunity through the Kalstein Plus platform.

Frequently Asked Questions

What types of materials can be sterilized with these models?

You can sterilize a variety of instruments made from materials such as glass, metal, and ceramics, as long as they fall within the diameter specifications.

How do I maintain the sterilizer?

Basic maintenance involves ensuring the internal and external cleanliness of the unit, checking for any signs of wear, and regular inspection of heating elements to prevent malfunction.

Is specialized training required to operate these sterilizers?

While the equipment is designed for ease of use, it is recommended to follow provided guidelines and undergo basic operational training to maximize efficiency and safety.

Advantages and Disadvantages

Advantages include high-temperature efficiency, dual power options, variable size accommodations for instruments, and durable construction ensuring long-term use. The compact design also aids in maximizing space utility within laboratory settings.

Disadvantages might encompass the initial heating time of 10 minutes, which could impact workflow if immediate sterilization is essential. Additionally, potential users need to ensure compatibility with the available laboratory power supply requirements.

Use of the Product in the Field

Infrared sterilizers like the YR06040 and YR06041 play pivotal roles in laboratory environments. They are versatile tools that ensure the sterility of delicate instruments within microbiology labs, research facilities, and medical environments. Their high-temperature range effectively eliminates contaminants, bacteria, and other forms of microorganisms within seconds of exposure, offering peace of mind to researchers and clinicians. They are particularly effective for sterilizing surgical instruments, petri dishes, and metal loops used in microbial culturing processes.

These sterilizers’ easy integration into existing workflows makes them a preferred choice for initiating and concluding laboratory procedures. The models’ adaptability to handle different instrument sizes ensures that labs of varying capacities can rely on a robust sterilization process without unnecessary manual adjustments.

Recommendations

To gain maximum benefit from your infrared sterilizer, we advise positioning the device within a well-ventilated area to facilitate effective heat dissipation. Regularly inspect and clean both the chamber and the outer surfaces to prevent unwanted buildup and ensure consistent performance. It is also beneficial to keep detailed logs of sterilization cycles, as this can assist in monitoring both performance efficiency and instrument sanitation frequencies.

Moreover, periodic calibration and careful review of power settings are recommended to ensure the execution of precise sterilization cycles. Utilizing the features provided, such as standby temperatures, can significantly enhance operational readiness and reduce preparation times.

If you are seeking a fusion of innovation and quality, you have come to the right place. At Kalstein we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our online shopping channels, intuitive and agile, are designed for your convenience, ensuring the most friendly prices. Do not hesitate any longer, we give life to science, it is time to be part of our community. https://kalstein.net/en/product/infrared-sterilizer-yr06040-yr06041/

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]