Advanced Sterilization Technologies: A Comprehensive Look at the YR05758-1 Model

Product Description

The YR05758-1 rapid cooling culture medium sterilizer is an innovation in laboratory equipment, designed with precision and technological advancements that ensure optimal sterilization. Its vertical sliding door is automatic, making it user-friendly while maximizing safety during operations. This sterilizer is particularly notable for its substantial chamber size of 250L (550*550*850mm), which accommodates a wide variety of loads, making it versatile for diverse laboratory needs.

Engineered for efficiency, the overall dimensions of 1290*1200*1850mm and a substantial weight of 750 kg underscore its robust design. With a steam consumption of 16 kg per cycle and water consumption of 120 kg per cycle, it operates with a power usage of 22 kw, ensuring effective sterilization while maintaining energy efficiency. The sterilization temperature precision is impressive, with a control accuracy of ±0.2℃, a design temperature of 150℃, and temperature uniformity of ±0.5℃. Its maximum operating temperature is 139℃, ensuring efficient and reliable sterilization of sensitive materials.

Model YR05758-1
Chamber Size (W*H*D) 250L
550*550*850mm
Overall dimensions (L*W*H) 1290*1200*1850mm
Weight (kg) 750
Steam consumption (kg/cycle) 16
Water consumption (kg/cycle) 120
Power 22 kw
Generator design pressure 1.0 MPa
Sterilization temperature control accuracy ±0.2℃
Design temperature 150℃
Temperature uniformity ±0.5℃
Max. operating temperature 139℃
Chamber relief valve 0.28MPa
Maximum operating pressure 0.25MPa
Jacket relief valve 0.28 MPa

Market Price

In today’s competitive market, the price of advanced lab sterilizers like the YR05758-1 typically ranges between $31,500 to $32,300 USD. This price band takes into account the state-of-the-art features and high performance this model offers. It is important for potential buyers to compare features and ensure the best value for their investment. Despite its price, the productivity and reliability of the YR05758-1 make it a cost-effective solution for laboratories in need of consistent sterilization processes.

Frequently Asked Questions

What are the key benefits of the automatic vertical sliding door?

The automatic vertical sliding door enhances safety and ease of use. It improves workflow efficiency by allowing easy access to the chamber and minimizing the risk of injuries associated with manual doors.

How does the rapid cooling feature work?

The rapid cooling feature reduces waiting times between cycles, optimizing sterilization processes, and increasing throughput. This is particularly beneficial for high-demand environments that require fast turnaround times.

Advantages and Disadvantages

Advantages: The YR05758-1 offers superior sterilization with precise temperature control, enhancing reliability and safety in lab applications. Its robust build and large chamber size allow for varied uses, proving versatile beyond singular functions.

Disadvantages: While the initial cost is relatively high, it reflects the advanced technology and superior design of the equipment. Additionally, the operational weight of the sterilizer requires adequate space for installation and use.

Product Usage in the Field

In practice, the YR05758-1 proves essential for laboratories that require stringent sterilization processes, including research facilities, pharmaceutical labs, and universities. Its reliable temperature control ensures that even the most sensitive of materials are sterilized without compromise. The large chamber accommodates various types of equipment and materials, from glassware to complex media, underlining its flexibility in practical applications.

The YR05758-1 has been particularly instrumental in microbiology and biochemical labs, where precise sterilization is paramount. Its design and technological incorporation make it suitable for environments demanding efficiency and safety.

Recommendations

To maximize the utility of the YR05758-1, regular maintenance and calibration checks are recommended. Ensuring the sterilizer is used in accordance with manufacturer guidelines prolongs the device’s lifespan and ensures consistent performance. Consider the installation area; adequate space for ventilation and operation is crucial for its optimal functioning.

Routine training for laboratory personnel on its operation will help in maintaining safety standards and efficient use. For any laboratory looking to enhance its sterilization capabilities, investing in the YR05758-1 and leveraging platforms like Kalstein Plus for queries will guarantee a worthwhile venture.

If you’re seeking a union of innovation and quality, you’ve come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online shopping channels are designed for your convenience, ensuring the most friendly prices. Do not hesitate any longer; we bring science to life and it’s time for you to become part of our community. Explore Now.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]