Product Description
The Total Organic Carbon (TOC) Analyzer YR04949 is a state-of-the-art instrument designed for precision and efficiency in organic carbon analysis. Equipped with a Non-Dispersive Infrared (NDIR) detector, this analyzer accurately measures Total Carbon (TC), Total Inorganic Carbon (TIC), Total Organic Carbon (TOC), and Non-Purgeable Organic Carbon (NPOC). The high temperature combustion mode ensures complete digestion of samples, making it suitable for a wide range of liquid samples. Operable via PC software, it offers a user-friendly interface for seamless data management and analysis.
This device requires an oxygen purity of ≥ 99.995% and operates within a measurement range of 0-30000 mg/l (ppm), with a stringent detection limit of 50 μg/l (ppb). It promises a repeatability rate of 3% and can handle a maximum sample salinity of 85 g/l. Designed for versatility, it offers power options of AC220V, 50Hz, or AC110V, 60Hz, consuming 200W. Compact in its dimensions, the analyzer measures 430x455x440 mm, ensuring efficient use of laboratory space.
| Model | YR04949 |
| Detector | NDIR |
| Parameters | TC, TIC, TOC, NPOC |
| Digestion Mode | High Temperature Combustion |
| Operation Mode | PC Software Controlled |
| Application | Liquid Sample |
| Gas Requirement | Oxygen ≥ 99.995% |
| Measurement Range | 0-30000mg/l (ppm) |
| Detection Limit | 50μg/l (ppb) |
| Repeatability | 3% |
| Maximum Salinity | 85g/l |
| Power | AC220V, 50Hz or AC110V, 60HZ, 200W |
| Size | 430*455*440mm |
Market Price
The Total Organic Carbon Analyzer YR04949 is a premium instrument, reflecting its advanced capabilities and reliability. In the market, devices like this typically range between $26,400 and $27,200, a sensible investment for laboratories aiming to enhance their analytical precision. While this price may seem considerable, the analyzer’s robust performance and durability provide compelling value for its price range. By choosing this analyzer, laboratories can ensure precise carbon measurements, leading to better results in research and routine analysis.
FAQs
How often does the TOC Analyzer YR04949 require maintenance?
Routine maintenance of the TOC Analyzer YR04949 typically involves regular inspections based on usage frequency. It is advisable to adhere to the manufacturer’s guidelines to ensure optimal performance and longevity.
What types of samples can the analyzer process?
The YR04949 is specifically designed for liquid samples, making it versatile for applications in various industries such as environmental monitoring, pharmaceuticals, and wastewater treatment.
Is there any specific training required to operate the analyzer?
While prior experience with laboratory equipment is beneficial, the user-friendly PC software ensures a swift learning curve, allowing users to efficiently operate the device with minimal training.
Advantages and Disadvantages
Advantages: The YR04949 offers exceptional sensitivity with its low detection limit, ensuring accurate analysis even in trace concentrations. Its high repeatability guarantees consistent results, which is critical for research and quality control. Additionally, the compact design facilitates easy integration into any laboratory setup.
Disadvantages: The initial investment might be higher compared to basic models, which could be a consideration for smaller laboratories with tight budgets. Furthermore, the analyzer requires high-purity oxygen for optimal performance, necessitating an additional supply setup.
Field Usage
In practical scenarios, the YR04949 is invaluable in water quality testing, where rapid and precise TOC analysis is essential. Its robust design ensures reliable performance across various environmental conditions, making it a preferred choice in both stationary labs and mobile testing units. The analyzer’s capability to handle high salinity makes it suitable for marine and coastal water studies as well.
During field deployments, the automated features and software control allow for efficient data collection and analysis, significantly reducing manual effort and error probabilities, thereby improving productivity.
Recommendations
To maximize the performance of the TOC Analyzer YR04949, ensure that operating conditions adhere to the specified requirements, especially in terms of gas purity and power supply. Scheduling periodic maintenance checks will extend the device’s life and ensure consistent accuracy. Moreover, integrating this analyzer with data management systems enhances its utility in generating detailed analytical reports.
For laboratories aiming to upgrade their analytical capabilities, incorporating the YR04949 will deliver both precision and efficiency. Prospective buyers are encouraged to request a quote or use the Kalstein Plus platform for an automated quote to facilitate a smooth acquisition process.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each device with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the friendliest prices. Do not hesitate any longer, we bring science to life, it’s time to be part of our community. https://kalstein.net/en/product/total-organic-carbon-analyzer-yr04949/.