Product Description
The Class II A2 Biological Safety Cabinets from Kalstein are engineered to offer superior protection for both the personnel and the environment during the handling of pathogenic biological samples. These cabinets come in four model variants: YR0090B(SS), YR0090C(SS), YR0090D(SS), and YR0090E(SS), each designed to maximize the efficiency of laboratory operations while ensuring safety.
Each model operates on a rotated voltage of 220 V and a frequency of 50HZ, providing a stable and reliable power source suitable for continuous laboratory use. Ergonomically designed for single or double person operations, these cabinets cater to varying laboratory needs with dimensions that range from 1000 to 1800 mm in width.
The cabinets are equipped with high-efficiency HEPA (ULPA) filters, achieving a filtration efficiency greater than 99.999% for particles as small as 0.3 micro-meters (0.12). This makes them an essential component in maintaining a contaminant-free lab environment. An average noise level under 67 dB guarantees a quiet operational setting, enhancing focus and productivity within the workspace.
| Parameter / Model | YR0090B(SS) | YR0090C(SS) | YR0090D(SS) | YR0090E(SS) |
| Rotated Voltage | 220 V | |||
| Roted Frequency | 50HZ | |||
| Number Of People | SINGLE PERSON | DOUBLE | ||
| Overall Dimension | 1000*765*2000MM | 1200*765*2000MM | 1500*765*2000MM | 1800*765*2000MM |
| Operating Space | 800*630*700MM | 1000*630*700MM | 1300*630*700MM | 1600*630*700MM |
| Rated Power | 1100W | 1800W | ||
| Total System Exhaust | 360M3/h | 500m3/h | ||
| Uv Lamp Power | 30w | 40w | ||
| Fluoroscent Lamp Power | 12w*2(LED) | 16W*2 (LED) | ||
| Average Falling Wind Speed | 0.33+-0.25M/S | |||
| Average Suction Wind Speed | 0.53+-0.25M/S | |||
| Filtrtion Efficiency | HEPA (ULPA) High Efficiency Filter, FOR 0.3 U M (0.12) Particle Filtration Efficiency > 99.999% (99.9995%) | |||
| Noise | <67 Db (A) | |||
Market Price
The market price for Class II A2 Biological Safety Cabinets typically ranges from $5800 to $6600. These prices reflect the cabinets’ advanced technology and superior safety features, ensuring a worthwhile investment in the safety and efficiency of your laboratory.
Frequently Asked Questions
What is the purpose of a Biological Safety Cabinet?
Biological Safety Cabinets are designed to provide a contamination-free environment for laboratory work involving biological samples, thereby protecting personnel, products, and the surrounding environment.
How often should the HEPA filter be replaced?
The HEPA filter usually needs replacement every three years, but this may vary based on frequency and conditions of use.
Is it easy to operate these cabinets?
Yes, the cabinets are designed for user-friendly operation, with intuitive controls and efficient ergonomic design suitable for laboratory use.
Advantages and Disadvantages
Advantages:
One of the prime advantages of these cabinets is their high-efficiency filtration system, which guarantees the removal of microscopic contaminants. The low noise level enhances comfort for laboratory technicians, while versatile sizing offers flexibility to suit various laboratory spaces. The energy-efficient LED lighting also contributes to reduced operational costs.
Disadvantages:
While these cabinets are highly effective, they can be considered a significant initial investment. Regular maintenance is required to ensure the optimal performance of filtration and airflow systems, which could increase operational costs over time.
Product Usage in the Field
Class II A2 Biological Safety Cabinets are an essential piece of equipment in laboratories working with infectious materials. They are predominantly used in microbiological laboratories, pharmaceutical settings, and clinical diagnostic labs, offering protection for experimental procedures involving disease-causing organisms. The contained environment provided by these cabinets guarantees safe manipulation of samples under controlled conditions.
Field professionals achieve the best results by complying with the standardized procedures of operation and maintenance, securing the longevity and efficacy of the cabinet.
Recommendations
To maximize the efficiency and longevity of your Biological Safety Cabinet, ensure regular internal and external cleaning using appropriate disinfectants. It is also crucial to schedule routine inspections and maintenance, including airflow verification and filter integrity checks. Adequate documentation of maintenance records will also help in sustaining the warranty validity and enhancing equipment performance.
An additional recommendation is to utilize the cabinet within its operational limits, avoiding overloading to maintain the optimal airflow and filtration efficacy. Ensure to update the user training frequently for smooth operational dealings.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each unit with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the friendliest prices. Don’t hesitate any longer; we bring science to life, it’s time to be part of our community. https://kalstein.net/en/product/biological-safety-cabinet-class-ii-a2-yr0090b-ss-yr0090e-ss/.