Product Description
The Laminar Flow Cabinet YR05746 stands as a beacon of innovation and design in laboratory environments. It provides both horizontal and vertical air supply, ensuring flexibility and superior contamination control. The cabinet achieves a cleanliness level of Class 100@≥0.5μM, adhering to the US Federal 209E standard, which guarantees an almost sterile working atmosphere. One of the most notable features is its capability to maintain colony counts of ≤0.5pcs/dish·hour on a 90mm culture plate, showcasing its efficiency in controlled settings.
The cabinet accommodates a single user efficiently with a focused single side design, making it perfect for specialized tasks requiring high precision. Additionally, the flow cabinet keeps noise levels at a minimum, registering at ≤62dB(A), allowing a calm and productive laboratory environment. The power supply requirement is AC single-phase 220V/50Hz with an average wind speed adjustability ranging from 0.25-0.45m/s, enhancing user flexibility during various laboratory applications.
| Model | YR05746 |
| Air Supply | Horizontal and vertical air supply |
| Cleanliness level | Class 100@≥0.5μM (US Federal 209E) |
| Number of colonies | ≤0.5pcs/dish·hour (Φ90mm culture plate) |
| Average Wind Speed | 0.25~0.45m/s(Fast and slow) |
| Noise | ≤62dB(A) |
| Power Supply | AC single-phase 220V/50Hz |
| Illuminance | ≥300Lx |
| Vibration half peak | ≤5μM(x、y、z direction) |
| Max. Power Consumption | 800W |
| Dimension of Working area | 1320x510x600 |
| Overall dimension | 1475x745x1815 |
| Specification and quantity of high efficiency filter | 1320x600x38x 1 / 1320 x 484 x 38 x 1 |
| Specification and quantity of fluorescent lamp/ultraviolet lamp | 30Wx1 / 30Wx1 |
| Applicable Persons | Single person-single side |
Market Price
Understanding the investment required for high-quality laboratory equipment is crucial for budgeting and planning. The Laminar Flow Cabinet YR05746, with its advanced features and reliable performance, is competitively priced in the market. Typically, cabinets of this calibre are available in the range of $2700 to $3500 USD. This range ensures you are not only investing in a piece of equipment but in the sustained productivity and safety of your laboratory operations.
Frequently Asked Questions
What is the power consumption of the YR05746 model?
The Laminar Flow Cabinet YR05746 has a maximum power consumption of 800 watts, which is efficient given its extensive functionalities.
Is this model suitable for two users simultaneously?
No, the design is optimized for single person-single side use, ensuring focused and controlled handling during critical laboratory processes.
Advantages and Disadvantages
Advantages:
This cabinet offers a pristine working environment with compliance to stringent cleanliness standards. The adjustable wind speed and low noise levels enhance user comfort, and the illumination of ≥300Lx ensures excellent visibility. The cabinet’s dual air supply options provide versatility in installation and operation, making it adaptable to various experimental needs.
Disadvantages:
While the cabinet’s tailored design optimizes it for single-user applications, it may not be ideal for labs that require simultaneous, multi-user access. Additionally, users need to ensure adequate space for its installation due to its specific dimensions.
Usage in the Field
In practical applications, the Laminar Flow Cabinet YR05746 serves as an indispensable tool across a multitude of laboratory settings, from research facilities to pharmaceutical and industrial labs. It is predominantly used in experiments that demand sterile conditions, such as tissue culture work, microbiological testing, and pharmaceutical preparations. By delivering a contamination-free workspace, the cabinet plays a critical role in ensuring the integrity and reliability of experimental outcomes.
Furthermore, its intuitive control systems and robust build enable seamless integration into existing lab setups, resulting in enhanced workflow efficiency and productivity.
Recommendations
To maximize the utility and lifespan of your Laminar Flow Cabinet YR05746, regular maintenance is recommended. This includes routine checks on air filters and timely replacement when necessary to maintain optimal airflow and cleanliness levels. Additionally, it is advisable to periodically recalibrate the cabinet’s airflow settings to align with the latest experimental requirements.
For labs operating with limited space, plan the layout comprehensively to ensure the cabinet’s dimensions are accommodated without compromising laboratory mobility. Always adhere to the manufacturer’s guidelines for operational and safety protocols to ensure consistent performance and user safety.
If you’re ready to enhance your laboratory with cutting-edge technology, consider reaching out for a customized quote. Our platform, Kalstein Plus, offers an easy and convenient way to explore pricing options and tailor the purchase to suit your specific needs. Let us help you take the next step in your scientific endeavors.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each equipment with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the friendliest prices. Do not hesitate any longer, we bring science to life, it’s time to be part of our community. https://kalstein.net/en/product/laminar-flow-cabinet-yr05746/.