Product Description
The Recirculating Chillers YR02302-YR02305 series are designed to offer precision temperature control for various laboratory and industrial applications. Operating within a temperature range of -10°C to 25°C, these chillers ensure exceptional performance with a temperature stability of ±2°C. One of the standout features is their capacity to maintain consistent cooling power across activities, essential for sensitive experiments and processes.
All models in this series utilize R134a refrigerant, recognized for its efficiency and eco-friendliness. The power supply ranges differ slightly within the series, with models YR02302, YR02303, and YR02304 operating on 220-240V, 50Hz, and model YR02305 on 380V, 50Hz, ensuring that there is an option suitable for various power specifications needed in different settings.
| Model | YR02302 | YR02303 | YR02304 | YR02305 |
| Operating temperature range | -10-25°C | |||
| Temperature stability | ± 2°C | |||
| Power supply | 220-240V-, 50Hz | 3-, 380V, 50Hz | ||
| Filling volume of bath liquid (L) | 10 | 17 | 30 | 40 |
| Cooling capacity (W) | 1000@15°C | 2000@15°C | 3000@15°C | 6000@15°C |
| Refrigerant | R134a | |||
| Circulation pump flow | 7L/min | 16L/min | ||
| Pressure (bar) | 1-10 | |||
| Pipe connection size | 1 / 2″ | |||
| Dimensions (mm) | 435W x 6900 x 720H | 465W x 6900 x 820H | 495W x 7600 x 860H | 650W x 1055D x 1070H |
| Net weight / kg) | 73 | 86 | 108 | 195 |
Market Price
The market price for recirculating chillers like the YR02302-YR02305 series generally begins at around 17,500 USD and can range upwards to 18,300 USD, depending on the model and its specifications. This price reflects the cutting-edge technology and durability provided by these chillers, making them a versatile and reliable choice for various applications. It is important to consider the operational efficiencies and precision these chillers offer when evaluating their value against other market offerings.
Frequently Asked Questions
What is the main application of recirculating chillers?
Recirculating chillers are widely used in laboratories, medical equipment cooling, and industrial processes where precise temperature control is essential.
How do these chillers ensure environmental safety?
These chillers use R134a refrigerant, which is known for having no ozone depletion potential and a low global warming potential.
Are there any specific maintenance requirements?
Regularly checking the refrigerant levels and cleaning the components will ensure optimal performance and longevity of the chillers.
Advantages and Disadvantages
Advantages: One of the key advantages of the YR02302-YR02305 series of recirculating chillers is their ability to maintain temperature stability within a narrow range of ±2°C, thus ensuring consistent and reliable results. Furthermore, the diverse cooling capacities ranging from 1000W to 6000W provide an option for various application scales, while the use of an environmentally friendly refrigerant like R134a adds to their appeal.
Disadvantages: On the downside, the main limitation could be their initial cost, which may seem high for smaller operations. Additionally, ensuring the correct installation and calibration might require professional assistance to achieve optimal performance.
Field Applications
The Recirculating Chillers YR02302-YR02305 are employed across a range of settings, from laboratories conducting chemical reactions requiring precise temperature conditions to manufacturing processes where heat must be efficiently managed. In pharmaceutical environments, they are essential for maintaining the stability of temperature-sensitive compounds during testing phases.
In the industrial sector, these chillers are crucial for processes such as laser cooling, electroplating, and plastic molding, where they aid in consistent and efficient production outcomes. Their ability to manage high workloads and maintain stable operations is unrivaled, allowing industries to maximize their output efficiencies.
Recommendations
For optimal results using the YR02302-YR02305 recirculating chillers, it is recommended to pair them with compatible equipment that operates within the specified temperature and pressure ranges. Routine servicing and adherence to recommended maintenance schedules will further ensure longevity and efficiency.
Users should consider the chiller’s operational environment, ensuring that installations are carried out in well-ventilated areas to maintain performance. It is also advisable to employ water filtration systems to prevent blockages within the piping, which could lead to reduced flow rates or system inefficiencies.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online purchasing channels are designed for your comfort, ensuring the most friendly prices. Don’t hesitate any longer, we bring science to life; it’s time to become part of our community. https://kalstein.net/en/product/recirculating-chiller-yr02302-yr02305/.