Description of the Product
The **YR02180 Doppler Fetal Monitor** is setting new standards in fetal monitoring with its cutting-edge technology and user-friendly design. This advanced device is engineered specifically to aid healthcare professionals in effectively monitoring fetal heart rates and other essential parameters, ensuring optimal maternal care. The device features a sophisticated electrocardiogram (ECG) system with a 5-lead mode, providing comprehensive monitoring capabilities and offering superior connectivity with I, II, III, AVR, AVL, AVF, and V methods.
In addition to ECG capabilities, the YR02180 is equipped with an efficient heart rate monitoring system, covering a range of 40 to 240 bpm, with a precision of ±3 bpm. This makes it a reliable tool for healthcare professionals monitoring patients in various stages of labor. Its sensitivity, greater than 200 uVp-p, alongside a resolution of 1 bpm, ensures precise tracking and evaluation.
The respiration module operates effectively using impedimetric methodology, capable of detecting impedance within the range of 0.3 to 3.0 MΩ, and provides accurate respiration rate measurements for adults (7 to 120 BrPM) as well as neonatal and pediatric patients (7 to 150 BrPM). This device is also equipped with NIBP (non-invasive blood pressure) monitoring, SPO2 (oxygen saturation), and temperature measurements, making it an all-encompassing monitoring solution in medical settings.
| Model | YR02180 | |
|---|---|---|
| ECG | Lead mode | 5 Leads (RA, LA, LL, RL, V) |
| Connection method | I, II, III, AVR, AVL, AVF, V | |
| Lead Mode | 3 Leads (RA, LA, LL) | |
| Connection method | I, II, III | |
| Gain | x250, x500, x1000, x2000 | |
| Accuracy | ±5% | |
| Resolution | 1bpm | |
| Sensitivity | >200(uVp-p) | |
| Differential input impedance | ≥5MΩ | |
| ST segment Monitoring Range | ||
| Measure Range | -1.0~+1.0mV | |
| Measure Accuracy | -0.8mV~+0.8mV | |
| Heart Rate | Measuring range | 40~240bpm |
| Accuracy | ±3bpm | |
| Resolution | 1bpm | |
| Sensitivity | >200UVp-p | |
| Respiration | Method | Impedance between R-F(RA-LL) |
| Measuring Impedance Range | 0.3~3.0 MΩ | |
| Bandwidth | 0.1~2.5Hz | |
| Respiration Rate | Adult: 7~120BrPM | |
| Neo/Ped | 7~150BrPM | |
| Resolution | 1 BrPM | |
| Accuracy | ±2 BrPM | |
| NIBP | Method | Oscillometric |
| Measuring Interval in AUTO Mode | 1,2,3,4,5,10,15,30,60,90,120,180,240(Min) | |
| Measuring Period in STAT Mode | 5 Min | |
| Pulse Rate Range | 40~240bpm / 40~150bpm | |
| Alarm Type | SYS, DIA, MEAN | |
| Resolution | ||
| Pressure | 1mmHg | |
| SPO2 | Display | Number of SPO2, waveform of capacity, Pulse |
| Measuring range | 0~100% | |
| Resolution | 1% | |
| Accuracy | 70~99% (±2%) | |
| Pulse rate range | 0~300bpm | |
| TEMP | Channel | 2 |
| Measuring and Alarm Range | 0~50ºC | |
| Resolution | 0.1ºC | |
| Accuracy | 0.1ºC | |
| Actualization interval | about 1 Second. | |
| Average Time Constant | <10 Second. | |
Market Price
The YR02180 Doppler Fetal Monitor is competitively priced in the market, offering remarkable features that typically retail between **$3,400 USD and $4,200 USD**. This investment will provide healthcare professionals with an advanced tool that significantly enhances patient monitoring capabilities.
Frequently Asked Questions
What is the ECG lead configuration of the YR02180?
The YR02180 supports a 5-lead ECG configuration, allowing for comprehensive monitoring with leads RA, LA, LL, RL, V.
How accurate is the heart rate measurement?
The accuracy of the heart rate measurement is ±3 bpm, making it highly reliable in clinical settings.
What is the refresh interval for temperature measurements?
The temperature measurements refresh approximately every second, ensuring continuous monitoring.
Advantages and Disadvantages
**Advantages:** The YR02180 is a highly advanced monitoring device combining multiple functionalities, including ECG, SPO2, NIBP, and temperature monitoring, into one compact unit. Its high accuracy and sensitivity make it an invaluable tool for fetal monitoring. The wide measuring ranges and auto mode allow for automated tasks, minimizing practitioner workload.
**Disadvantages:** As with many sophisticated devices, there may be a learning curve for individuals unfamiliar with comprehensive monitoring systems. Additionally, its advanced features may come at a higher cost than basic models, which could be a consideration for smaller medical practices.
Product Usage in the Field
In practical scenarios, the YR02180 is used by obstetricians and midwives to monitor fetal wellbeing continuously. Utilizing its accurate ECG leads and robust heart rate monitoring system, practitioners can detect any irregularities or changes in fetal conditions promptly.
Its NIBP and SPO2 functionalities are particularly useful in monitoring maternal health, ensuring that blood pressure and oxygen levels remain within safe limits throughout the pregnancy and labor stages. Its comprehensive monitoring capabilities make it indispensable in maternity wards, clinics, and hospitals globally.
Recommendations
To maximize the efficiency and lifespan of the YR02180 Doppler Fetal Monitor, ensure regular calibration according to the manufacturer’s guidelines and maintain the device in a clean, dust-free environment. Familiarize your healthcare staff with its functions and capabilities through user training sessions.
Employing the YR02180 in your healthcare facility not only optimizes patient care but also enhances your facility’s trust and credibility. For additional resources or inquiries, consider engaging with Kalstein’s customer support.
If you are seeking a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece with a level of excellence. Our intuitive and agile online shopping platforms are designed for your convenience, ensuring the friendliest prices. Don’t hesitate anymore, we bring science to life, it’s time to become part of our community. https://kalstein.net/en/product/doppler-fetal-monitor-yr02180/