The automotive industry, as well as many chemical fields, rely heavily on precise measurement instruments. The ATC car refractometers YR05916-YR05930 offer an impeccable fusion of accuracy, usability, and advanced materials, making it an essential tool for professionals in these industries. These refractometers, with their Automatic Temperature Compensation (ATC) capabilities, ensure that you get reliable measurements, irrespective of environmental temperature fluctuations.
Product Description
The ATC car refractometers range YR05916-YR05930 is meticulously designed, providing superior accuracy and ease of use. Each model is crafted from high-quality pure aluminum, ensuring durability and longevity. These refractometers feature a measurement range suitable for various applications, with specific ranges like 1.000-1.400sg, temperature ranges from -70°C to 0°C for ethylene glycol and propylene glycol, and concentration measures for Adblue®. The minimum division is consistently at 0.01sg, and accuracy is maintained at ±0.01sg, ensuring precision across all measurements.
Key features include effective ATC between 0-30°C, allowing professionals to perform measurements accurately without being affected by ambient temperature changes. The pure aluminum construction enhances performance, providing a sturdy and reliable device for regular use in challenging environments.
| Model | Description | Measurement Range | Min. Div. | Accuracy | ATC | ATC Temp. | Material |
| YR05916 | Car ATC E:-60°C–0°C P:-50°C-0°C B:1.100-1.400sg optical | B:1.000-1.400sg, E:-60℃-0℃, P:-50℃-0℃, | 0.01sg 5℃ 5℃ |
±0.01sg ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
| YR05917 | Car ATC E:-60°C–0°C P:-50°C-0°C B:1.100-1.400sg optical | B:1.000-1.400sg, E:-60℃-0℃, P:-50℃-0℃ | 0.01sg 5℃ 5℃ |
±0.01sg ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
| YR05918 | Car ATC E:-60°F-32°F P:-50°F-32°F B:1.15-1.30sg optical | B:1.15-1.30sg, E:-60°F-32°F, P:-50°F-32°F | 0.01sg 5℃ 5℃ |
±0.01sg ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
| YR05919 | Car ATC E:-60°F-32°F P:-50°F-32°F B:1.15-1.30sg optical | B:1.15-1.30sg, E:-60°F-32°F, P:-50°F-32°F | 0.01sg 5℃ 5℃ |
±0.01sg ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
| YR05920 | Car ATC E:-50°C-0°C P:-50°C-0°C B:1.15-1.30sg optical | B:1.15-1.30sg, E:-50℃-0℃, P:-50℃-0℃ | 0.01sg 5℃ 5℃ |
±0.01sg ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
| YR05921 | Car ATC E:-50°C-0°C P:-50°C-0°C B:1.15-1.30sg optical | B:1.15-1.30sg, E:-50℃-0℃, P:-50℃-0℃ | 0.01sg 5℃ 5℃ |
±0.01sg ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
| YR05922 | Car ATC E:-50°C-0°C P:-50°C-0°C C:-40°C-0°C B:1.15-1.30sg | E:-50°C-0°C P:-50°C-0°C C:-40°C-0°C B:1.15-1.30sg | 0.01sg 5℃ 5℃ 5℃ | ±0.01sg ±5℃ ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
| YR05923 | Car ATC E:-50°C-0°C P:-50°C-0°C C:-40°C-0°C B:1.15-1.30sg | E:-50°C-0°C P:-50°C-0°C C:-40°C-0°C B:1.15-1.30sg | 0.01sg 5℃ 5℃ 5℃ | ±0.01sg ±5℃ ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
| YR05924 | ATC B:1.100-1.400sg E:-50°C-0°C P:-50°C-0°C C:-40°C-0°C | B:1.100-1.400sg E:-50℃-0℃ P:-50℃-0℃ C:-40℃-0℃ | 0.01sg 5℃ 5℃ 5℃ | ±0.01sg ±5℃ ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
| YR05925 | ATC B:1.100-1.400sg E:-50°C-0°C P:-50°C-0°C C:-40°C-0°C | B:1.100-1.400sg E:-50℃-0℃ P:-50℃-0℃ C:-40℃-0℃ | 0.01sg 5℃ 5℃ 5℃ | ±0.01sg ±5℃ ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
| YR05926 | ATC E:-70°C-0°C(-90°F-32°F),P:-60°C-0°C(-70°F-32°F)B:1.100-1.400sg | E:-70°C-0°C (-90°F-32°F) P:-60°C-0°C (-70°F-32°F) B:1.100-1.400sg | 5°C (10°F) 5°C (10°F) 0.01sg | ±5°C (10°F) ±5°C (10°F) ±0.01sg | Yes | 0-30°C | Pure aluminium |
| YR05927 | ATC E:-70°C-0°C(-90°F-32°F),P:-60°C-0°C(-70°F-32°F)B:1.100-1.400sg | E:-70°C-0°C (-90°F-32°F) P:-60°C-0°C (-70°F-32°F) B:1.100-1.400sg | 5°C (10°F) 5°C (10°F) 0.01sg | ±5°C (10°F) ±5°C (10°F) ±0.01sg | Yes | 0-30°C | Pure aluminium |
| YR05928 | ATC Adblue: 30%–35%B:1.100- 1.400sg E:-50°C-0°C P:- 50°C-0°C C:-40°C-0°C optical refractometer | Adblue: 30%–35%B:1.100-1.400sg E:-50℃-0℃ P:-50℃-0℃ C:-40℃-0℃ | 0.01sg 5℃ 5℃ 5℃ | ±0.01sg ±5℃ ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
| YR05929 | ATC Adblue: 30%–35%B:1.100- 1.400sg E:-50°C-0°C P:- 50°C-0°C C:-40°C-0°C optical refractometer | Adblue: 30%–35%B:1.100-1.400sg E:-50℃-0℃ P:-50℃-0℃ C:-40℃-0℃ | 0.01sg 5℃ 5℃ 5℃ | ±0.01sg ±5℃ ±5℃ ±5℃ | Yes | 0-30°C | Pure aluminium |
| YR05930 | RHA-801 ATC 0-40% Urea Concentration AD Blue Optical | 0%-40% Urea Concentration | 0.2%Urea Concentration | ±0.2%Urea Concentration | Yes | 10-30° C | Pure aluminium |
Market Price
When considering precision measurement tools like the ATC car refractometers, the price point varies based on the advanced features they offer. These devices typically range from $70, indicating a starting point for more economical models, to an average market price between $80 and $240. This pricing reflects not only the precision and reliability you gain but also the robustness of materials used in the construction of these refractometers.
Frequently Asked Questions
What is the Automatic Temperature Compensation (ATC) feature?
The ATC feature automatically adjusts the refractometer to correct for temperature variations, ensuring more accurate readings across different environmental conditions.
What substances can I measure with these refractometers?
These refractometers are designed to measure ethylene glycol, propylene glycol, and specific urea concentrations like Adblue®, making them versatile for automotive applications.
How durable is the ATC car refractometer?
Constructed from pure aluminum, these refractometers boast exceptional durability, ensuring long-lasting performance even in rigorous settings.
Advantages and Disadvantages
Advantages: The ATC car refractometers are marked by their precision and reliability, facilitated by their automatic temperature compensation. Their robust aluminum construction not only ensures durability but also contributes to consistent measurement accuracy. The wide measurement range makes these refractometers suitable for various applications, from automotive to chemical industries.
Disadvantages: Despite the numerous benefits, one potential drawback could be the calibration requirements needed to maintain optimal performance over time. Regular maintenance may be necessary to ensure the refractometers provide consistent accuracy.
Usage in the Field
In practical applications, the ATC car refractometers prove invaluable in the automotive sector, ensuring that fluid concentrations in vehicles are optimal. They enable mechanics to measure coolant and antifreeze concentrations accurately, preventing engine overheating and ensuring performance efficacy. Additionally, in the chemical industry, these refractometers provide accurate measurements for similar purposes, facilitating quality control and fluid management.
Given their robust design and precise functionality, these refractometers are suitable for both field and laboratory environments, providing users with versatile measurement solutions.
Recommendations
To maximize the lifespan and accuracy of the ATC car refractometers, it is recommended to regularly clean and calibrate the device according to the manufacturer’s instructions. Ensure the refractometer is handled with care to avoid any potential damage to the optical components. Proper storage, particularly avoiding exposure to extreme temperatures or conditions, can further ensure the durability and reliability of these units. For the most convenient purchasing and pricing solutions, consider reaching out through the Kalstein Plus platform for a streamlined experience.
If you’re searching for a fusion of innovation and quality, you’ve come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the friendliest prices. Don’t hesitate any longer, we bring science to life; it’s time to be part of our community. https://kalstein.net/en/product/atc-car-refractometers-yr05916-yr05930/