Product Description
The Multifunctional Imager Models YR06210 and YR06211 represent the cutting edge in the field of scientific imaging. Designed to cater to a broad spectrum of laboratory applications, these imagers are highly versatile, providing exceptional performance in chemiluminescence and fluorescence imaging, as well as ECL Western Blotting.
One of the standout features of these models is their imaging capabilities. Whether you need to work with gel documentation applications or focus on protein gels and SDS pages, both models deliver superior results, ensuring maximum clarity and precision. Model YR06210 uses a back illuminated SCMOS sensor with a resolution of 9.0 Megapixels, while the YR06211 is equipped with a front illuminated CCD sensor offering 6 Megapixels.
These imagers also maintain a consistently regulated temperature of -30 °C, ensuring stable operation under various conditions. Featuring a dynamic range of 4.8 OD and pixel density of 16 bit (65536 grey scales), they accommodate a range of imaging needs. The Auto focus lens with standard F0.95 (optional F0.8) provides unmatched focusing precision, making it invaluable in detailed imaging tasks.
| Model | YR06210 | YR06211 | |
| Application | Chemilluminescence Imaging, ECL Western Blotting | YES | YES |
| Fluorescence Imaging, Fluorescent Western Blotting | YES | YES | |
| Gel Doc Application | YES | YES | |
| Protein gel; SDS Pages | YES | YES | |
| Standard Parameters | Sensor | Back illuminated SCMOS Sensor | Front illuminated CCD Sensor |
| Resolution | 9.0 Megapixels | 6 Megapixels | |
| Pixel Size | 3.76 × 3.76 μm | 4.54 x 4.54 μm | |
| Temperature | -30 °C regulated | ||
| Dynamic Range | 4.8OD | ||
| Pixel density | 16bit(65536 Grey scales) | ||
| Lens | F0.95 as standard (optional F0.8) Auto focus | ||
| Chemilluminescence Sample tray | Electronic Lifting Platform for diverse sizes of western blotting membranes | ||
| DNA/RNA detection | Electronic Lifting Blue LED Transmission for DNA/RNA detection | ||
| Protein gel; SDS Pages | Electronic Lifting White LED Transmission for Protein Gels | ||
| Software | SHST Capture and Analysis Software for unlimited number of users | ||
| Optional Accessories | Epi-UV, RGB and NIR fluorescent detection | ||
| Removable industrial computer, 13.1 Inch Touch Screen, Intel processor | |||
Market Price
The Multifunctional Imager models YR06210 and YR06211 are available in the market within a typical price range of $25,000 to $26,000 USD. This pricing reflects the high-quality components and advanced technology used in these models, making them a valuable investment for laboratories looking to enhance their imaging capabilities.
Frequently Asked Questions
What kind of imaging applications are supported?
Both models support a variety of imaging applications including chemiluminescence imaging, fluorescence imaging, and gel documentation, which makes them highly versatile for scientific research.
What is the resolution of these imagers?
The YR06210 model offers a high resolution of 9.0 Megapixels, while the YR06211 model provides a resolution of 6 Megapixels, both supporting detailed and clear imaging outputs.
How are these imagers cooled?
They feature a regulated cooling system that maintains a constant temperature of -30 °C, ensuring stable and efficient imaging performance across various applications.
Advantages and Disadvantages
Advantages: The main advantages of the YR06210 and YR06211 models include their advanced imaging technology, versatile application range, and robust construction capable of enduring intensive laboratory use. The sophisticated sensor technology ensures high precision and clarity in imaging results, alongside the user-friendly SHST software designed for extensive usability.
Disadvantages: The potential downside of these models could be their higher price range, which might be a consideration for smaller laboratories with tighter budgets. Additionally, the multitude of features may necessitate a learning curve for optimal usage.
Field Use of the Product
The Multifunctional Imager models YR06210 and YR06211 are extensively employed in scientific research laboratories. They are vital for protein analysis and gene detection, aiding researchers in detailed imaging processes essential in molecular biology, genetics, and related fields. The electronic lifting platform simplifies handling diverse western blotting membranes, making repetitive lab tasks more efficient.
In practice, these imagers are also used for academic purposes, offering students hands-on experience with advanced imaging tools. Their precise detection and data output enhance the accuracy of experimental results, driving forward both educational and professional research endeavors.
Recommendations
For optimal performance and longevity of the YR06210 and YR06211 Multifunctional Imagers, it is recommended to adhere to routine maintenance checks, including regular calibration and cleaning of the sensors. Users should ensure the software is updated to take advantage of the latest features and improvements for enhanced functionality.
Additionally, it’s advantageous to be familiar with both the application range and the technical specifications to exploit the full potential of these imagers in various research contexts. Engaging with the available optional accessories can further expand the functionality and imaging capabilities, tailoring the equipment to specific laboratory needs.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the most friendly prices. Don’t hesitate any longer, we bring science to life; it’s time to be part of our community. https://kalstein.net/en/product/multifunctional-imager-yr06210-yr06211/.