Product Description
The Double Beam Spectrophotometer YR01862 series offered by Kalstein is a state-of-the-art instrument designed to deliver precise and reliable analytical results in laboratory settings. This sophisticated equipment is characterized by its innovative double beam optical system, which provides enhanced accuracy and stability during measurements. The series includes two models: YR01862-1 and YR01862-2, both engineered for outstanding performance.
The core of the YR01862 spectrophotometer is the imported tungsten and deuterium lamps it employs, ensuring a broad wavelength range from 190 nm to 1100 nm. This allows for diverse analytical applications, ranging from UV to visible spectrums. While both models share the same wavelength capability, they differ in bandwidth, where the YR01862-1 model offers a consistent 1.0 nm bandwidth, and the YR01862-2 model provides variable bandwidth selections including 0.5, 1.0, 2.0, 4.0, and 5.0 nm.
| Specification | YR01862-1 | YR01862-2 |
|---|---|---|
| Optical System | Double beam | Double beam |
| Light Source | Imported tungsten lamp & deuterium lamp | Imported tungsten lamp & deuterium lamp |
| Wavelength Range | 190-1100nm | 190-1100nm |
| Bandwidth | 1.0nm | 0.5, 1.0, 2.0, 4.0, 5.0 nm |
| Display | 10-inch HD smart touch screen | 10-inch HD smart touch screen |
| Control Mode | Stand-alone system/PC software | Stand-alone system/PC software |
| Data Output | Bluetooth and USB port | Bluetooth and USB port |
Market Price
The market price for high-performance spectrophotometers, such as the YR01862 series, generally ranges between 7000 USD to 8300 USD. This range reflects the quality and precision offered by these instruments, making them a valuable investment for laboratories requiring accurate spectral analysis. Potential buyers interested in acquiring this cutting-edge technology are encouraged to contact Kalstein for precise pricing details, or better still, generate a quote automatically through our Kalstein Plus platform.
Frequently Asked Questions
What is the benefit of a double beam spectrophotometer?
Double beam spectrophotometers offer enhanced measurement stability compared to single beam models by compensating for fluctuations in light source intensity and other variables.
How does the variable bandwidth feature of the YR01862-2 benefit analysis?
The variable bandwidth offers flexibility in accommodating different types of samples and analysis requirements, providing the ability to choose the optimal resolution for each specific application.
Is the spectrophotometer compatible with modern data systems?
Yes, it features Bluetooth and USB ports for seamless data transfer and integration with advanced data systems.
Advantages and Disadvantages
Advantages: The YR01862 series boasts several strengths, including high accuracy due to its double beam design, a comprehensive wavelength range for versatile application, and user-friendly controls via its 10-inch HD smart touch screen. Moreover, the stand-alone capabilities and PC software compatibility ensure ease of use and integration into existing lab setups.
Disadvantages: A notable consideration is the higher initial investment compared to simpler spectrophotometers, which might be a limiting factor for some smaller laboratories. Additionally, the advanced features may require some learning curve for operators new to sophisticated analytical devices.
Field Usage
In practical applications, the Double Beam Spectrophotometer YR01862 series is widely used in chemical analysis, quality control processes, and research laboratories. Its ability to perform consistent and accurate measurements makes it an indispensable tool for determining the concentration of substances by analyzing light absorbance. The device’s robust design also ensures reliable performance under varied laboratory conditions, making it ideal for both routine and advanced spectral analysis tasks.
The capability of exporting data via Bluetooth and USB facilitates seamless integration with data management systems, enhancing productivity and reducing the time required for manual data handling.
Recommendations
To maximize the performance and longevity of the YR01862 spectrophotometer, regular maintenance and calibration are advised. Ensure the light source is frequently checked and replaced if necessary, as this affects measurement accuracy. Additionally, take advantage of the PC software for data analysis and storage to maintain an organized and efficient workflow.
Training staff on the operational aspects of the spectrophotometer is also recommended to ensure accurate results and avoid potential mishandling. For a comprehensive understanding of its functionalities, users can access Kalstein’s support resources or contact their customer service for guidance.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online shopping channels are designed for your convenience, ensuring the most friendly prices. Don’t hesitate any longer, we bring science to life, and it’s time to become part of our community. https://kalstein.net/en/product/spectrophotometer-double-beam-yr01862-1-yr01862-2/