Product Description
The YR02194 Infant Bilirubin Phototherapy Unit represents a pinnacle of innovation in neonatal care. Specifically designed to effectively treat jaundice in newborns, this unit utilizes an efficient blue light source, crucial for the decomposition of bilirubin. The device operates with an input power of less than 150VA, ensuring energy efficiency without compromising on performance. Its blue tube light source boasts an impressive effective life of 1000 hours, facilitating long-term use with minimal interruptions.
Working within a wavelength range of 400-550nm, the YR02194 ensures optimal precision and therapeutic efficacy. Its pliability in terms of use is enhanced with an irradiance treatment distance ranging from 10 to 500px, and a generous effective area of 1125px by 600px. Designed with the safety of infants in mind, the phototherapy unit has an infrared radiation measure of ≤10mW/cm² (760nm<λ≤1400nm) and ultraviolet radiation ≤1.0×10-5mW/cm² (180nm<λ≤400nm), ensuring a safe treatment environment.
This state-of-the-art device maintains operational noise levels at ≤55dB(A), creating a serene setting conducive to comfort and care. Its basic performance guarantees a total irradiance (Ebi) of ≥500μW/cm², providing the therapeutic intensity needed for effective bilirubin breakdown. Users can also benefit from customizable angles of 30°, 60°, and 90°, alongside an adjustable height range of 1100mm to 1500mm, allowing seamless adaptation to various clinical scenarios.
| Model | YR02194 |
| Input power | <150VA |
| Light source | Blue tube |
| Light source effective life | 1000 hours |
| Wave length | 400-550nm |
| Irradiance treatment distance | 10~500px |
| Effective area | 1125px×600px |
| Infrared radiation in effective area | ≤10mW/cm2(760nm<λ≤1400nm) |
| Ultraviolet radiation in effective area | ≤1.0×10-5mW/cm2 (180nm<λ≤400nm) |
| Operate noise | ≤55dB(A)(ambit noise is lower than 40dB(A)) |
| Basic performance | the equipment total irradiance (Ebi) ≥500μW/cm2 |
| Adjust angle | 30°,60°,90° |
| Adjust height | 1100mm~1500mm |
Market Pricing
The YR02194 Infant Bilirubin Phototherapy Unit is competitively priced within the market, offering a range from approximately 500 USD to 800 USD based on different suppliers and geographic locations. This pricing spectrum reflects the unit’s advanced functionality and high-quality performance, ensuring value for every investment made within this range.
Frequently Asked Questions
How does the blue light work to reduce bilirubin levels?
The blue light of this phototherapy unit facilitates the conversion of bilirubin molecules in the body into products that can be excreted via urine and feces, thus efficiently decreasing bilirubin levels in newborns.
Is the unit easy to operate?
Yes, the YR02194 is designed for user-friendly operation with adjustable height and angle settings, simplifying its integration into various neonatal care environments.
What maintenance is required for the unit?
Routine maintenance involves cleaning the unit’s exterior surfaces and periodically checking the light source for consistent performance, ensuring long-term functionality and safety.
Pros and Cons
Pros: This phototherapy unit stands out due to its high energy efficiency and long-lasting blue tube light source. Its precise wavelength range ensures optimal treatment results. The unit’s adjustable height and angles maximize its adaptability in different clinical settings, and it operates quietly, enhancing the care environment.
Cons: As with any specialized medical equipment, initial investment costs and training for proper use might be considerations for some healthcare facilities. However, the long-term benefits and efficacy of the YR02194 often outweigh these potential drawbacks.
Application in the Field
The YR02194 is primarily employed in neonatal care units for the treatment of hyperbilirubinemia (jaundice) in newborn infants. Its effective light range and adjustable features allow practitioners to administer targeted phototherapy sessions tailored to individual patient needs. This device is integral in maintaining health standards and improving neonatal outcomes by reducing bilirubin levels effectively and safely.
Furthermore, its lightweight design and ease of mobility make it a versatile choice for both large hospitals and smaller clinics. It provides a reliable solution where space and resource constraints may be present, ensuring no compromise on the quality of care provided to these vulnerable patients.
Recommendations
For optimal performance, it is advisable to conduct regular equipment checks and ensure that the blue light source is replaced as needed after reaching its 1000-hour lifespan. Furthermore, understanding and training on the unit’s adjustable features can maximize its usability and effectiveness within clinical settings.
To enhance patient care, it is beneficial to integrate the phototherapy unit with proper monitoring protocols to track bilirubin levels and adjust treatment duration accordingly. This proactive approach ensures the best therapeutic outcomes for neonatal patients under your care.
Incorporating this advanced unit into your neonatal practice today can significantly elevate the standard of care you provide. Request a quote or generate an automatic estimate via Kalstein Plus, and take the next step in advancing your clinical capabilities.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online purchase channels are designed for your convenience, ensuring the most friendly prices. Don’t hesitate any longer; we bring science to life, and it’s time to become part of our community. https://kalstein.net/en/product/infant-bilirubin-phototherapy-unit-yr02194/.