The Infant Phototherapy Incubator YR02183 is a state-of-the-art medical device designed to provide optimal care for newborns requiring phototherapy. With features that ensure precise temperature control and low noise operation, this incubator is engineered to meet the complex needs of neonatal care. Powered by an electrical requirement of ~220V 59Hz or -230V 60Hz, this incubator consumes ≤450VA, making it efficient and reliable.

One of the most critical features of the YR02183 is its temperature management capabilities. It supports both air mode and skin mode temperature ranges from 25.0°C to 37.0°C, ensuring the infant remains in a controlled and comfortable environment. An air over temperature range of <38.0°C and an air mode high temperature range from 37.1°C to 39.0°C provide additional safety and adaptability. Alarms for air mode and skin mode—set at ±3.0°C and ±1.0°C, respectively—add an extra layer of security by alerting medical staff to any deviations from set temperatures.

Model YR02183
Electrical requirement ~220V 59Hz or -230V 60Hz
Power consumption ≤450VA
Air mode temperature range 25.0°C~37.0°C
Skin mode temperature range 25.0°C~37.0°C
Air over temperature range <38.0°C
Air mode high temperature range 37.1°C~39.0°C
Skin mode high temperature range 37.1°C~38.0°C
High temperature mode alarm <40.0°C
Air mode alarm ±3.0°C
Skin mode alarm ±1.0°C
Skin sensor accuracy ≤±3.0°C
Air control accuracy ≤0.5°C
Mattress temperature uniformity ≤0.8°C
Noise ≤55dB (A)

Market Price

When considering the investment in an Infant Phototherapy Incubator, understanding the market price is essential for budgeting in medical facilities. The YR02183 falls into a reasonable range. Typically, such advanced medical devices have market prices ranging from approximately $2600 to $3400, depending on the seller, additional features, and any service agreements included. This price range reflects the high-performance characteristics and reliability of the YR02183.

Investing in an incubator like the YR02183 ensures that hospitals and clinics are equipped with technology that supports enhanced patient care and meets rigorous medical standards. For facilities looking to ensure the best neonatal outcomes, the cost is justifiable against the quality and peace of mind the device provides.

Frequently Asked Questions

What makes the Infant Phototherapy Incubator YR02183 unique?

The YR02183 is distinguished by its precise temperature control, low power consumption, and integrated alarm system that safely monitors infant conditions. Its design aligns with modern neonatal care standards, making it indispensable in medical settings.

How does the alarm system work?

The alarm system is designed to alert healthcare providers of any fluctuations beyond the set temperature ranges in both air and skin modes. This ensures that any anomalies can be addressed swiftly to maintain a safe environment for infants.

Is the incubator easy to clean and maintain?

Yes, the YR02183 is designed with user-friendly maintenance in mind. Its surface and components can be cleaned easily to prevent infections and ensure a hygienic environment for newborns.

Advantages and Disadvantages

Advantages: The YR02183 offers numerous advantages, such as unmatched temperature precision, a highly sensitive alarm system, and noise levels below 55 dB(A), ensuring a quiet environment for newborns. Its low power consumption enhances cost-effectiveness for facilities.

Disadvantages: Despite its numerous benefits, some users might find the initial investment significant. However, considering its long-term benefits and role in neonatal health, it remains a valuable asset.

Product Use in the Field

In real-world settings, the YR02183 incubator is crucial for providing phototherapy to jaundiced infants. Its design ensures that newborns receive consistent and effective light therapy, while the stable environment contributes to overall infant health. Hospitals and clinics globally have adopted the YR02183 due to its reliability and ease of use.

Nurses and doctors find it intuitive to operate, with straightforward controls that can be easily adjusted as per the baby’s requirements. The dependable alarm system provides confidence to healthcare workers, fostering a secure environment for vulnerable infants.

Recommendations

For optimal use, facilities should ensure regular calibration of the YR02183 to maintain its temperature accuracy and functionality. Personnel should undergo training to familiarize themselves with its features and operation. This will not only prolong the product’s lifespan but also enhance the quality of infant care provided.

Patients considering purchasing the YR02183 are encouraged to request a detailed demonstration and training session. For secure transactions and to explore more high-quality medical devices, consider generating an automated quote through the Kalstein Plus platform. This approach ensures you make an informed decision based on comprehensive insights.

If you’re seeking a blend of innovation and quality, you’ve come to the right place. At Kalstein we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the most user-friendly prices. Do not hesitate any longer, we bring science to life, it’s time to become part of our community. https://kalstein.net/en/product/infant-phototherapy-incubator-yr02183/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]