Product Description
The Vertical 408L Ultra Low Temperature Freezer, model YR05108, represents a pinnacle of innovation in cold storage solutions. Designed with scientific precision for laboratories, research facilities, and medical environments, this freezer ensures optimal preservation of critical samples. One of its standout features includes the stainless steel interior with three durable shelves, providing ample space of 408 liters (14.40 cu.ft) to organize and store samples efficiently.
The freezer utilizes direct cooling technology paired with a manual defrost system, which provides consistent temperature control ranging from -40 to -86°C, essential for the preservation of sensitive biomaterials. Equipped with a high-performance SECOP compressor and environmentally friendly mixed-gas refrigerant, the freezer is not only effective but energy-efficient, consuming just 12 kWh/24h and operating quietly at a noise level of 50 dB.
| Specifications | Details |
|---|---|
| Model | YR05108 |
| Shelf/drawer QTY | Stainless steel shelf/3 |
| Cooling | Direct cooling |
| Defrost | Manual |
| Refrigerant | Mixed-gas |
| Power Consumption(kWh/24h) | 12 |
| Noise(db) | 50 |
| Ambient temperature(℃) | 10~32℃ |
| Temperature range(℃) | -40~-86℃ |
| Compressor brand/QTY | SECOP/1 |
| Sensor | PTC |
| Temperature controller | Microprocessor |
| Display | Digital display |
| Voltage/frequency(V/Hz) | 220/50Hz |
| Power(W) | 890W |
| Current(A) | 4.6A |
| Inside material | Stainless steel |
| Outside material | Color sprayed steel |
| Insulation | PURF |
| Capacity(L/cu.ft) | 408/14.40 |
| NT./GT.(kg) | 234/291 |
| Exterior size(W*D*H)(mm) | 890*930*1945 |
| Interior size(W*D*H)(mm) | 606*575*1180 |
| Package size(W*D*H)(mm) | 955*955*2100 |
| CBM | 1.92 |
| 20GP/40GP/40HQ | 12/24/24 |
| Racks | 16(5X4,4X4) |
| Boxes (2 Inches) | 288 |
| Samples(2ml) | 28800 |
| High/low temperature | Yes |
| Power failure | Yes |
| Abnormal voltage | Yes |
| Sensor error | Yes |
| Filter screen check | Yes |
| Thermostat failure | Yes |
| Low battery | Yes |
| Condenser clean | Yes |
| High ambient temperature | Yes |
| Door ajar | Yes |
| Power failure backup system(alarm) | 72h |
| Castor | Yes |
| Inside door | 2 |
| Test hole QTY/diameter | 1/25MM |
| USB port | Yes |
| Chart recorder | / |
| Data logger | Optional |
| Remote alarm port | Yes |
| CO2 back up system | Optional |
| LN2 back up system | Optional |
| Certification | ISO, CE |
Market Price
The Vertical 408L Ultra Low Temperature Freezer is competitively priced given its advanced technology and features. On average, freezers of this category are within a range of $6000 to $6900 USD, accommodating different budget aspects for diverse lab settings. While the initial investment might seem substantial, the long-term preservation benefits and energy efficiency offset the cost over time.
Frequently Asked Questions
What kind of refrigerant does this freezer use?
The Vertical 408L Ultra Low Temperature Freezer uses an environmentally friendly mixed-gas refrigerant.
Is there an automatic defrost option?
Currently, this model is equipped with a manual defrost system.
What kind of alarms are included?
The freezer includes a comprehensive alarm system covering high/low temperature, power failure, voltage abnormalities, sensor errors, and more.
Advantages and Disadvantages
Advantages: The Vertical 408L Ultra Low Temperature Freezer offers exceptional durability with a stainless steel interior that withstands rigorous lab environments. Its expansive storage capacity allows for meticulous organization. The freezer’s energy efficiency is another strong point, minimizing operational costs. Additionally, the wide temperature range makes it versatile for various types of sample preservation.
Disadvantages: While the manual defrost system offers precise control over ice buildup, it requires regular attention to maintain optimal performance. Users must also ensure the ambient conditions are within the specified range for ideal function.
Usage in the Field
The Vertical 408L Ultra Low Temperature Freezer is indispensable in scenarios requiring the long-term storage of biological samples, pharmaceuticals, and other temperature-sensitive materials. Laboratories focused on research and development, medical facilities storing vaccines, and industrial applications all leverage this freezer for its reliability. Proper usage involves organizing samples methodically on its shelves, ensuring even temperature distribution, and routinely monitoring the digital display for any irregularities.
Recommendations
To extend the life span and efficiency of your Vertical 408L Ultra Low Temperature Freezer, it is crucial to follow some recommended practices. Regularly conduct maintenance checks, including filter cleaning and system diagnostics, to preempt any potential issues. Optimize the storage layout for airflow, and avoid frequent door openings to maintain a stable temperature. Consider leveraging available accessories, such as a data logger, to enhance temperature monitoring capabilities effectively.
If you’re seeking a fusion of innovation and quality, you have arrived at the right place. At Kalstein, we offer you the luxury of browsing our exclusive laboratory equipment catalog. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online shopping channels are designed for your comfort, ensuring the most friendly prices. Don’t hesitate any longer; we bring science to life, and it’s time to become part of our community. https://kalstein.net/en/product/vertical-408l-ultra-low-temperature-freezer-manual-defrost/.