Product Description
The YR05726 Laminar Flow Cabinet is a cutting-edge piece of laboratory equipment designed to create a particle-free working environment by directing air in a horizontal unidirectional stream, thus safeguarding sensitive processes. This state-of-the-art cabinet adheres to the US Federal Standard 209E, ensuring a *Class 100* cleanliness level at particle sizes ≥0.5μM, making it an exceptional choice for laboratories requiring high levels of cleanliness and contamination control.
This product boasts a robust construction with meticulous specifications. The cabinet limits the number of colonies to ≤0.5pcs/dish·hour using a Φ90mm culture plate, while maintaining an average wind speed ranging from 0.25 to 0.45m/s. With noise levels kept to a minimum at ≤62dB(A) and a vibration half peak at ≤5μM across x, y, and z directions, the YR05726 assures a quiet and stable work environment. The illuminance of the cabinet is at least 300Lx, offering ample light for precision tasks.
| Model | YR05726 |
| Cleanliness Level | Class 100@≥0.5μM (US Federal 209E) |
| Number of Colonies | ≤0.5pcs/dish·hour (Φ90mm culture plate) |
| Average Wind Speed | 0.25~0.45m/s |
| Noise | ≤62dB(A) |
| Vibration Half Peak | ≤5μM(x, y, z direction) |
| Illuminance | ≥300Lx |
| Power Supply | AC single phase 220V/50Hz |
| Maximum power | 100W |
| Weight | 80Kg |
| Work area size W1×D1×H1 |
700×410×580 860×590×1600 |
| Dimensions | Single/Single |
| High efficiency filter specification and quantity | 680×565×50 |
| Specification and quantity of fluorescent lamp/ultraviolet lamp | 12W×1 20W×1 |
Market Price
When considering the acquisition of the YR05726 Laminar Flow Cabinet, it is important to bear in mind its price range in the market. This industry-grade tool is generally available between approximately 1000 USD and 1800 USD, offering a competitive price for its remarkable technological advancements and robust specifications. A key factor to consider is the long-term benefits gained in terms of performance and reliability, which justify the investment.
Frequently Asked Questions
What is the main purpose of a laminar flow cabinet?
The primary purpose of a laminar flow cabinet is to safeguard processes and products within by providing a clean, contaminant-free environment through unidirectional airflow.
How does the YR05726 ensure cleanliness?
It maintains a cleanliness level of Class 100 as per US Federal 209E standards, filtering out particulates ≥0.5μM and using high-efficiency filters to maintain air purity.
Is the YR05726 suitable for microbiological work?
Yes, its design specifically helps in reducing the risk of contamination with maintained colony counts at ≤0.5pcs/dish·hour.
Advantages and Disadvantages
The YR05726 Laminar Flow Cabinet provides significant advantages for users operating in high-cleanliness environments. Key benefits include adherence to stringent cleanliness standards, precision in contamination control, and its operational efficiency marked by low noise and vibration levels. The cabinet’s durable design and effective lighting also contribute to usability.
On the downside, the premium nature of the YR05726 may elevate its initial cost, which is a consideration for budget-conscious facilities. Additionally, specialized maintenance may be required to ensure longevity and optimal performance, which could necessitate professional services.
Use of the Product in the Field
In practical settings, the YR05726 Laminar Flow Cabinet is instrumental in environments where contamination control is critical, such as pharmaceutical labs, electronic component assembly, and medical research. The horizontal airflow ensures particles are efficiently swept away from sensitive samples, while its noise and vibration control enhance focus and precision.
Technicians can rely on the reliability and consistency of the YR05726 to support accurate experimental processes, enforce product purity, and facilitate precise sample handling, thereby contributing significantly to the overall quality and success of laboratory operations.
Recommendations
To maximize the benefits of the YR05726, it is recommended to perform regular maintenance checks, including filter replacements and airflow assessments. Operators should follow manufacturer guidelines for setup and operation to preserve cabinet integrity. Regular training for technicians on proper use and handling of the equipment can also prevent misuse or damage.
Exploring the features of the YR05726 Laminar Flow Cabinet opens avenues to enhance laboratory efficiency, and Kalstein is prepared to assist customers in obtaining the equipment suited to their specific needs. Potential buyers are encouraged to request a quote or use the Kalstein Plus platform for an automatic estimate, optimizing their purchasing journey.
If you are seeking a fusion of innovation and quality, you’ve come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the friendliest prices. Do not hesitate any longer, we bring science to life, it is time to become part of our community. https://kalstein.net/en/product/class-100-horizontal-air-laminar-flow-cabinet-yr05726/.