Product Description
The Horizontal Cylindrical Pressure Steam Autoclave models YR05635 to YR05639 represent a pinnacle of engineering in sterilization technology. Characterized by their robust construction and precision performance, these autoclaves cater to a wide range of sterilization needs across various industries. Notably, they operate with a consistent work pressure of 0.22Mpa and achieve a steadfast work temperature of 134℃, ensuring reliable sterilization under stringent conditions.
These autoclaves provide a working temperature range between 105℃ and 134℃, allowing flexibility depending on the sterilization requirements. Their cycle times are optimized, with sterilization and drying times both adjustable from 0 to 60 minutes. This adaptability ensures that processes are tailored precisely to the materials and equipment being sterilized, enhancing operational efficiency.
The design includes chambers of varying capacities, from 150L to 500L, accommodating diverse sterilization needs with precision-engineered diameters and lengths for different operational scales. Each model boasts a superb thermal uniformity with an average heat deviation of ≤±1℃, guaranteeing consistent performance across the chamber.
| Model | YR05635 | YR05636 | YR05637 | YR05638 | YR05639 |
| Work Pressure | 0.22Mpa | ||||
| Work Temperature | 134℃ | ||||
| Working Temperature Range | 105-134℃ | ||||
| Sterilization Time | 0 – 60 minutes | ||||
| Drying Time | 0 – 60 minutes | ||||
| Average Heat | ≤±1℃ | ||||
| Chamber Size (mm) | 150L / Ø440×1000 | 200L / Ø500×1000 | 300L / Ø600×1080 | 400L / Ø700×1100 | 500L / Ø700×1300 |
| Outer Size (mm) | 1400×600×1300 | 1400×670×1650 | 1400×770×1780 | 1430×880×1830 | 1800×900×1820 |
| Packing Size (mm) | 1550×750×1850 | 1560×820×1850 | 1680×920×2100 | 1600×1050×2100 | 1850×1050×2100 |
| GW / NW | 320/240kg | 350/260kg | 465/365kg | 530/420kg | 580/470kg |
| Energy | 9kw | 9kw | 12kw | 18kw | 18kw |
Market Pricing
The market for horizontal cylindrical pressure steam autoclaves shows a dynamic range, reflecting the sophisticated technology and varying capacities of each model. Industry pricing typically spans from $13,000 to $13,500 on average. This range accommodates different configurations, capacities, and power requirements, presenting an array of options for institutions and laboratories aiming to elevate their sterilization practices.
Frequently Asked Questions
What are the key differences between the YR05635 to YR05639 models?
Each model varies primarily in chamber capacity, outer dimensions, and energy consumption. This allows users to select a model that best fits their volume and space requirements.
Can these autoclaves be used in biopharmaceutical laboratories?
Yes, these autoclaves are ideal for biopharmaceutical applications due to their precise temperature control and uniform heat distribution, enabling compliant and effective sterilization processes.
Advantages and Disadvantages
Advantages: The autoclaves are engineered with robust construction and precise temperature controls, offering significant flexibility with sterilization and drying cycles. This ensures high efficiency for varying sterilization needs.
Disadvantages: The initial investment for advanced models may be relatively high for smaller facilities. Additionally, larger space requirements for certain models could limit installation options in more compact lab environments.
Product Use in the Field
Within industrial and laboratory settings, these autoclaves serve diverse applications, including sterilizing laboratory instruments, glassware, and media preparation equipment. Their ability to adjust sterilization cycles and maintain temperature uniformity makes them incredibly versatile across numerous fields requiring health and safety compliance.
For example, in medical research labs, they are indispensable for ensuring that experimental results are not contaminated by biological agents. In pharmaceutical environments, they play a critical role in preparing sterile instruments and compounds essential for drug formulation and testing.
Recommendations
To maximize the efficiency and operational lifespan of these autoclaves, it is paramount to follow maintenance protocols which include regular cleaning of the chamber and periodic technical inspections by certified professionals. Ensuring the autoclave operates according to manufacturer guidelines will also prevent misuse and maintain its precision performance.
Furthermore, facilities should align their autoclave capacities with their sterilization needs to ensure optimal performance without unnecessary energy expenditure. Utilize the operational flexibility of the models to tailor the sterilization process accurately to your specific requirements.
If you are searching for a fusion of innovation and quality, you have reached the right place. At Kalstein, we offer you the luxury to explore our exclusive catalog of laboratory equipment. We manufacture each piece with a high level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the most competitive prices. Do not hesitate any longer; we bring science to life, it’s time to be part of our community. https://kalstein.net/en/product/horizontal-cylindrical-pressure-steam-autoclave-yr05635-yr05639/.