Product Description
The YR05730 Horizontal Air Supply Clean Bench is an advanced laboratory equipment designed to ensure precise and uncontaminated workspaces, making it indispensable for various scientific applications. This clean bench stands out with its Class 100 Cleanliness Level at ≥0.5μM, adhering to the stringent US Federal Standard 209E. Such high-level cleanliness ensures minimal particles in the air during sensitive laboratory procedures.
In terms of airflow, the YR05730 delivers a balanced and adjustable average wind speed of 0.25 to 0.45 meters per second. This feature, coupled with an illuminance of ≥300 Lux, creates an optimized environment for detailed work. Additionally, noise levels are kept to a manageable ≤62dB(A), reducing distractions and providing a comfortable atmosphere for laboratory personnel.
| Model | YR05730 |
| Cleanliness Level | Class 100@≥0.5μM (US Federal 209E) |
| Number of Colonies | ≤0.5pcs/dish·hour (Φ90mm culture plate) |
| Average Wind Speed | 0.25~0.45m/s |
| Noise | ≤62dB(A) |
| Vibration Half Peak | ≤5μM(x、y、z direction) |
| Illuminance | ≥300Lx |
| Power Supply | AC single phase 220V/50Hz |
| Maximum Power | 490W |
| Weight | 90kg |
| Work area size | 900×510×600 |
| W1×D1×H1 | 930×740×1440 |
| Dimensions | Single/Single |
| High efficiency filter specification and quantity | 830×560×50 |
| Specification and quantity of fluorescent lamp/ultraviolet lamp | 12W×1 20W×1 |
Market Price
The YR05730 Horizontal Air Supply Clean Bench is an economical yet high-performance solution for laboratories seeking a balance between cost and quality. Typically, the market price for this model ranges from $1500 to $2200, depending on the supplier and any additional options or services included. To obtain a precise quote tailored to your specific needs, feel free to leverage Kalstein’s innovative Kalstein Plus platform for an instant customized quotation.
Frequently Asked Questions
What is the primary function of the YR05730 Clean Bench?
This clean bench is primarily used to maintain a contamination-free environment for sensitive laboratory processes, including microbiology, tissue culture, and electronics assembly.
How does it maintain the Class 100 clean air environment?
The bench uses high-efficiency particulate air (HEPA) filters that capture airborne particles, ensuring the workspace remains at or above the cleanliness standards required.
Is it difficult to maintain the YR05730 Clean Bench?
No, maintaining the clean bench is straightforward, involving periodic checks and replacement of the HEPA filters and cleaning of the surfaces with recommended disinfectants.
Advantages and Disadvantages
The YR05730 Clean Bench offers several advantages, including superior air purity with Class 100 cleanroom conditions, a user-friendly design with adjustable airflow, and an energy-efficient operation with a maximum power of 490W. Its noise level, at ≤62dB(A), ensures a quiet working environment, which is critical for reducing operator fatigue and maintaining concentration during intricate laboratory tasks.
However, potential disadvantages may include the initial setup cost, which can be higher than for basic models that do not offer the same cleanliness levels. Furthermore, regular maintenance, while straightforward, is essential to ensure optimal performance, necessitating commitment from the user’s side.
Field Application
The YR05730 Horizontal Air Supply Clean Bench is widely used in various scientific and industrial applications. In microbiological laboratories, it provides the optimal environment for cultivating microorganisms, ensuring that samples remain uncontaminated by external air particulates. Additionally, it is ideal for electronics assembly and inspection, maintaining a dust-free environment essential for the quality and precision required in these processes.
In the pharmaceutical industry, it helps in the preparation of sterile products and compounds, significantly reducing the risk of contamination. These applications showcase the bench’s versatility and importance in maintaining product integrity across multiple fields.
Recommendations
To maximize the effectiveness and longevity of the YR05730 Clean Bench, it is crucial to adhere to routine maintenance schedules. This includes regular replacement of HEPA filters to maintain Class 100 conditions and ensuring the workspace is thoroughly cleaned after each use. Operators should be trained to understand the air flow design and to avoid obstructing airflow paths.
During use, placing non-essential items outside the clean workspace helps maintain optimal air quality, and frequent verification of the bench’s operational parameters will ensure it performs at peak efficiency. For precise maintenance schedules, consulting the manufacturer’s guidelines will be helpful.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the most friendly prices. Do not hesitate any longer, we bring science to life; it is time to become part of our community. https://kalstein.net/en/product/horizontal-air-supply-clean-bench-yr05730/.