State-of-the-Art Features of Tabletop Autoclave Class B for Efficient Sterilization

Product Description

The Tabletop Autoclave Class B, models YR03387, YR03388, YR03389, and YR03390, represent the pinnacle of sterilization technology, designed for environments demanding the highest standards of hygiene. These autoclaves are characterized by their diverse chamber volumes and configurations, making them suitable for various laboratory and clinical applications.

The YR03387 model features a chamber dimension of Ø170×320 mm and an 8 L volume, perfectly balancing compactness and efficiency. Meanwhile, the YR03388, with a 12 L capacity and chamber size Ø200×360 mm, offers greater flexibility for larger instruments. For even more demanding scenarios, the YR03389 and YR03390 provide 18 L and 23 L capacities, respectively, with chamber dimensions Ø247×350 mm and Ø247×450 mm, accommodating larger batches with ease.

The material construction includes durable aluminum trays for the YR03387, YR03389, and YR03390 models, with the YR03388 model showcasing stainless steel trays. This variety in tray materials ensures durability and efficiency in heat distribution, critical for optimal sterilization.

Model Number YR03387 YR03388 YR03389 YR03390
Chamber Dimension Ø170×320 mm Ø200×360 mm Ø247×350 mm Ø247×450 mm
Chamber Volume 8 L 12 L 18 L 23 L
Number of Trays 2/ Max. 3 2/ Max. 3 3/ Max. 5 3/ Max. 5
Material of Trays Aluminum Stainless Steel Aluminum Aluminum
Size of Trays. 130x265mm 156x295mm 192x285mm 192x380mm
Voltage Freq. 220/110V 220/110V 220/110V 220/110V
50/60Hz 50/60Hz 50/60Hz 50/60Hz
POWER.r 2000W 2000W 2000W 2200W
Overall Dimension (WxHxD) 420x370x525 mm 420x370x595 mm 490x455x600 mm 490x455x690 mm
Weight 37 kgs 40 kgs 47 kgs 53 kgs

Market Price

The Tabletop Autoclave Class B is a sophisticated piece of laboratory equipment, and the price range reflects its advanced capabilities and features. Typically, the market price for these autoclaves ranges from approximately 2000 USD to 3000 USD, depending on model specifications and additional features. This investment ensures a high standard of sterilization vital for laboratory and clinical settings. For precise pricing and to explore competitive offers, consider reaching out directly to distributors or generating a quote via the Kalstein Plus platform.

Frequently Asked Questions

What are the voltage requirements for these models?

All models operate on dual voltage settings, 220/110V, and support frequencies of 50/60Hz, making them adaptable for various geographical regions.

How many trays can these autoclaves accommodate?

The YR03387 and YR03388 models can hold a maximum of 3 trays, whereas models YR03389 and YR03390 can accommodate up to 5 trays, allowing for flexible use depending on the sterilization requirements.

Advantages and Disadvantages

Advantages: The Tabletop Autoclave Class B offers considerable benefits including a compact design for optimal space utilization, a variety of chamber sizes to suit different applications, and top-tier safety features that ensure reliable operation. The variable tray configurations and premium materials such as aluminum and stainless steel enhance sterilization efficiency and longevity.

Disadvantages: Although these autoclaves boast a range of advanced features, the initial investment cost can be high, potentially challenging for some facilities with limited budgets. Additionally, due to their technical complexity, staff must undergo proper training to ensure safe and effective operation.

Field Usage

In practical applications, the Tabletop Autoclave Class B is indispensable across diverse settings, including hospitals, dental offices, and laboratories, where equipment sterilization is crucial. The autoclave is used for sterilizing surgical instruments, laboratory glassware, and other equipment by applying high-pressure saturated steam. This ensures complete sterilization, eliminating any microbial life, including bacterial spores.

The versatility of these autoclaves makes them suitable for both routine and specialized sterilization tasks, providing peace of mind and safety for healthcare providers and researchers alike.

Recommendations

To maximize the efficacy and lifespan of your Tabletop Autoclave Class B, regular maintenance is essential. It is recommended to conduct periodic checks of seals, trays, and other components subject to wear. Proper loading techniques, ensuring no overcrowding of trays, will enhance steam penetration and sterilization efficiency. Additionally, adhering to manufacturer guidelines for use and maintenance will prevent operational issues and guarantee long-term reliability.

If you are seeking a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece with a level of excellence. Our online purchasing channels, intuitive and agile, are designed for your convenience, ensuring the most friendly prices. Do not hesitate any longer, we bring science to life, it is time to become part of our community. https://kalstein.net/en/product/tabletop-autoclave-class-b-yr03387-yr03390/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]