UV-5600: Cutting-Edge UV-Vis Spectrophotometer Features for Precision and Innovation

Product Description

The UV-5600 model, specifically the YR01854, is an advanced UV-Vis spectrophotometer designed to meet the rigorous needs of both research and industrial applications. This spectrophotometer offers a broad wavelength range from 190 nm to 1100 nm, making it suitable for a wide array of analyses. The device features a 2 nm bandwidth that enhances the resolution and precision of your measurements.

The UV-5600 provides unparalleled wavelength accuracy of ±0.5 nm and repeatability of ≤0.2 nm, ensuring that you obtain reliable data with every use. Its automated wavelength setting simplifies operation, while photometric accuracy of ±0.3%T and repeatability of 0.2%T allow for dependable absorbance and transmittance measurements.

Engineered for stability, the UV-5600 maintains an impressive baseline flatness of ± 0.002A/h and stray light is kept at ≤0.05%T at 220 nm and 360 nm. The built-in 128*64 Dots LCD display offers clear, real-time data visualization.

Model YR01854
Wavelength Range 190-1100nm
Bandwidth 2nm
Wavelength Accuracy ±0.5nm
Wavelength Repeatability ≤0.2nm
Wavelength Setting Auto
Photometric Accuracy ±0.3%T
Photometric Repeatability 0.2%T
Photometric Range -0.3-3A, 0-200%T, 0-9999C
Stability ± 0.002A/h @ 500nm
Baseline Flatness ± 0.002A/h
Stray Light ≤0.05%T@220nm, 360nm
Data Output Port USB
Printer Port Parallel Port
Display 128*64 Dots LCD
Lamps Tungsten Lamp & Deuterium Lamp
Detector Silicon Photodiode
Power Requirements AC 220V/50Hz or AC 110V/60Hz
Dimension 460*360*225mm
Weight 18kg

Market Price

The UV-5600 spectrophotometer, given its array of advanced features, is competitively priced in the market. Typically, you can expect the price range to be between $3500 and $4300. This robust pricing reflects the device’s precision engineering and high-quality components. It’s important to consider that investing in such equipment not only enhances productivity but also ensures precise and reproducible results across various applications.

If you’re considering incorporating this model into your laboratory, you can easily generate an automatic quote via Kalstein Plus, ensuring you receive competitive pricing tailored to your needs.

Frequently Asked Questions

What is the model number of the UV-Vis spectrophotometer?

The model number is YR01854.

What is the wavelength range of the UV-5600?

The wavelength range is from 190 nm to 1100 nm.

Can the UV-5600 be used for industrial applications?

Yes, the spectrophotometer is suitable for both research and industrial applications, providing accurate and reliable data.

Advantages and Disadvantages

Advantages: The UV-5600 stands out with its high degree of accuracy and repeatability. The wide range of wavelengths it can measure makes it versatile for different studies. Its automated features simplify usage, reducing user error and improving consistency in results. The device’s USB and parallel port interfaces enable easy data management and printing of results.

Disadvantages: One potential drawback is its weight, as it weighs 18 kg, which may make it less portable than lighter models. Additionally, the sophisticated nature of its features may require a learning curve for users new to advanced spectrophotometric technology.

Product Use in the Field

The UV-5600 is extensively used in chemical analysis, environmental studies, and biochemistry for quantifying and qualifying different samples. Its broad range of wavelengths allows it to analyze a variety of substances, from phytochemicals to proteins, under diverse experimental conditions. Laboratories focused on quality control often opt for this spectrophotometer due to its accurate data output and stability over time.

In environmental monitoring, the device can measure absorbance in samples containing pollutants or nutrients, aiding in environmental assessment and management. The UV-5600’s capability to handle high-throughput analysis efficiently makes it an invaluable tool in any laboratory setting.

Recommendations

To maximize the use of the UV-5600, it is recommended to regularly calibrate the device and ensure that all components such as lamps and the photodiode detector are maintained optimally. Users should also receive adequate training to harness all the features of the spectrophotometer effectively. Consistent adherence to maintenance schedules extends the equipment’s lifespan and enhances data accuracy.

For laboratories using the UV-5600 frequently, it is advisable to keep a spare tungsten or deuterium lamp on hand to avoid operational interruptions. Regular software updates, if available, should be installed to take full advantage of new functionalities and improvements.

If you’re looking for a fusion of innovation and quality, you’ve come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalogue of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online purchasing channels are designed for your comfort, ensuring the most friendly prices. Hesitate no more, we bring science to life, it’s time to become part of our community. https://kalstein.net/en/product/ultraviolet-visible-uv-vis-spectrophotometer-yr01854/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]