The Total Organic Carbon Analyzer YR04950 is at the forefront of modern laboratory technology, offering precise measurements and efficient analysis capabilities. This high-performance instrument is designed to cater to a variety of analytical needs, especially in assessing the quality of water by determining the organic carbon content. Through its state-of-the-art detection and operation methods, it provides reliable results for both research and industrial applications.

Product Description

The YR04950 model is a cutting-edge Total Organic Carbon (TOC) Analyzer equipped with several key features that ensure optimal performance. The analyzer employs a Non-Dispersive Infrared (NDIR) detector, a vital component that enhances its sensitivity and accuracy. It operates using Wet Chemical Oxidation facilitated by UV, a method that ensures thorough oxidation of organic compounds for precise TOC measurements.

This instrument is PC software controlled, allowing for intuitive operation and data management directly from your computer. The analyzer is specifically designed for liquid samples and requires nitrogen gas with a purity of 99.995% for its operation. The measurement range extends from 0 to 10,000 mg/l (ppm), with a detection limit as low as 5 μg/l (ppb), guaranteeing high sensitivity even in minimal concentrations.

With a repeatability rate of 3%, the YR04950 delivers consistent results across different tests. Its tolerance for maximum salinity is 85g/l, making it suitable for a wide range of liquid samples. The device is powered by an AC voltage of either 220V at 50Hz or 110V at 60Hz, consuming 200W of power, and it comes in a compact size of 430x455x440mm.

Model YR04950
Detector NDIR
Parameters TC, TIC, TOC, NPOC
Method Wet Chemical Oxidation by UV
Operation Mode PC Software Controlled
Application Liquid Sample
Gas Requirement Nitrogen ≥99.995%
Measurement Range 0-10000mg/l (ppm)
Detection Limit 5μg/l (ppb)
Repeatability 3%
Maximum Salinity 85g/l
Power AC220V, 50Hz or AC110V, 60HZ, 200W
Size 430*455*440mm

Market Price

The Total Organic Carbon Analyzer YR04950, due to its advanced features and precision, typically falls within the market price range of $26,000 to $27,300. This range reflects the sophistication and functionality that this instrument offers to laboratories and research facilities. It is essential to engage with trusted suppliers who provide authentic products and reliable after-sale services.

Frequently Asked Questions

What are the primary applications of the YR04950?

The YR04950 is primarily used for measuring organic carbon content in water samples, which is crucial in environmental monitoring, pharmaceutical industries, and water treatment facilities.

How does the analyzer ensure accuracy?

The device uses a Non-Dispersive Infrared (NDIR) detector and UV-assisted Wet Chemical Oxidation to provide accurate and reliable results.

What gas is required for the operation of the YR04950?

The analyzer requires nitrogen gas with a purity of ≥99.995% to function correctly.

Advantages and Disadvantages

Advantages: The YR04950 offers several advantages, including high sensitivity with a detection limit of 5 μg/l, consistent results with a repeatability of 3%, and a broad measurement range suitable for various applications. Its PC software control allows for easy operation and data management.

Disadvantages: One of the potential drawbacks could be the requirement of high-purity nitrogen gas, which might incur additional operational costs. Additionally, the upfront cost is substantial, which might be a consideration for smaller laboratories.

Field Applications

The YR04950 is extensively used in laboratories engaged in environmental science, where it measures the total organic carbon content in water bodies. It plays a critical role in assessing water quality, ensuring compliance with environmental regulations. Industries such as pharmaceuticals benefit from this device by ensuring that their water purification processes meet stringent quality standards.

In real-world scenarios, the YR04950 can be integrated into water treatment plants, where continuous monitoring of organic compounds is necessary. Researchers also deploy this analyzer in field studies to obtain accurate data on organic pollution levels in various water sources.

Recommendations

To maximize the benefits of the YR04950, it’s advisable to ensure regular maintenance and calibration. Laboratories should schedule periodic checks to verify the analyzer’s precision and accuracy. It’s also recommended to use only high-quality samples and adhere to the specified operating conditions to prevent any discrepancies in results.

Interested in elevating your laboratory’s analytical capabilities? Explore the option to request a quotation or generate it automatically through the Kalstein Plus platform, ensuring a seamless acquisition process for your laboratory needs.

If you’re looking for a fusion of innovation and quality, you’ve come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the most friendly prices. Don’t hesitate any longer, we bring science to life, it’s time to become part of our community. https://kalstein.net/en/product/total-organic-carbon-analyzer-yr04950/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]