The Infant Phototherapy Incubator YR02183 exemplifies a blend of advanced technology and user-centric design, aimed at providing the best neonatal care. This state-of-the-art incubator integrates phototherapy capabilities, crucial for treating conditions like neonatal jaundice, while maintaining the precise environmental control needed for fragile infants.
One of its standout features includes dual temperature control modes: air mode and skin mode, both adjustable within a temperature range of 25.0°C to 37.0°C. Additionally, it boasts an air mode high temperature range of 37.1°C to 39.0°C and a skin mode high temperature range of 37.1°C to 38.0°C. It promises safety with a high temperature mode alarm set for temperatures under 40.0°C, ensuring a secure environment for infants.
The incubator operates with an electrical requirement of ~220V 59Hz or -230V 60Hz and consumes power up to 450VA, making it efficient for continuous use in medical settings. With advanced air and skin temperature alarms, its precision is undeniable, having ±3.0°C for air mode and ±1.0°C for skin mode. The skin sensor accuracy is guaranteed at ≤±3.0°C, while air control accuracy is maintained at ≤0.5°C. For comfort, the mattress ensures temperature uniformity within ≤0.8°C, all while keeping noise levels under ≤55dB(A).
| Specification | Details |
|---|---|
| Model | YR02183 |
| Electrical requirement | ~220V 59Hz or -230V 60Hz |
| Power consumption | ≤450VA |
| Air mode temperature range | 25.0°C~37.0°C |
| Skin mode temperature range | 25.0°C~37.0°C |
| Air over temperature range | <38.0°C |
| Air mode high temperature range | 37.1°C~39.0°C |
| Skin mode high temperature range | 37.1°C~38.0°C |
| High temperature mode alarm | <40.0°C |
| Air mode alarm | ±3.0°C |
| Skin mode alarm | ±1.0°C |
| Skin sensor accuracy | ≤±3.0°C |
| Air control accuracy | ≤0.5°C |
| Mattress temperature uniformity | ≤0.8°C |
| Noise | ≤55dB (A) |
Market Price
When considering investment in neonatal healthcare equipment, the pricing of the YR02183 Infant Phototherapy Incubator offers exceptional value for its advanced features. The market price for incubators of this caliber generally ranges from approximately 2700 USD to 3500 USD. This pricing reflects the precision engineering, innovative design, and exceptional reliability embedded in this model. Potential buyers should note that these prices can vary based on geographical location, distributor markup, and any additional features or extras included in the purchase.
Frequently Asked Questions
How does the phototherapy feature help infants?
The integrated phototherapy feature in the YR02183 model targets neonatal jaundice, a common condition in newborns. It effectively reduces bilirubin levels, ensuring a faster recovery and reducing the risk of more serious health issues.
What safety features are incorporated in this incubator?
This incubator is equipped with multiple alarms, including high temperature and mode alarms, along with skin sensor accuracy measures. It is specifically designed to maintain precise temperature control and provide warnings for any deviations.
Can this incubator be used in intensive care settings?
Absolutely. The YR02183 model is well-suited for neonatal intensive care settings due to its robust build, precision temperature control, and integrated phototherapy function.
Advantages and Disadvantages
The Infant Phototherapy Incubator YR02183 comes with a host of advantages. Notably, it offers precise temperature control for both air and skin modes, ensuring optimal conditions for neonatal care. The added benefit of a built-in phototherapy system is particularly advantageous for treating jaundice, giving an edge in comprehensive care.
However, potential users should consider the necessary electrical requirements and the potential initial investment cost. While these are standard considerations for high-quality medical equipment, they are essential factors in the decision-making process.
Field Product Use
In a clinical setting, the YR02183 model demonstrates its utility through seamless integration in neonatal units. By providing stable and adjustable temperature environments, it caters well to a variety of neonatal needs. With precise temperature control and reliable phototherapy treatment, it provides a comprehensive solution for hospitals and clinics specializing in newborn care.
Its user-friendly interface and precise alarm system make it a trusted choice for healthcare professionals, ensuring maximum reliability in critical care environments. The noise level, kept at a minimum, ensures a tranquil environment for both infants and staff.
Recommendations
For maximum effectiveness, it is recommended that the YR02183 Infant Phototherapy Incubator be utilized in conjunction with routine checks to maintain cleanliness and functionality. Regular calibration should be performed to ensure accuracy in temperature settings and alarm systems.
Professional training for practitioners on the features and functions of the incubator is advised to ensure all staff can operate it effectively and respond appropriately to its alerts and notifications. For those interested in comprehensive neonatal care solutions, exploring the Kalstein platform for automated quotation and additional model options is highly recommended. Visit our site to learn more about our products and how they can meet your healthcare needs.
If you are looking for a blend of innovation and quality, you have come to the right place. At Kalstein we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each equipment with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the most friendly prices. No longer hesitate, we bring science to life, it’s time to become part of our community. https://kalstein.net/en/product/infant-phototherapy-incubator-yr02183/.