Product Description
The LCD Display Hand Wheel Vertical Steam Autoclave series, comprising models YR05665 to YR05668, is engineered for precision and reliability in sterilization processes. These autoclaves operate with a maximum working pressure of 0.23Mpa, maintaining a consistent operation within a design temperature of up to 136℃. Users can adjust the working temperature from 105℃ to 134℃, with a sterilization time that ranges from 0 to 99 minutes or 0 to 99 hours 59 minutes, ensuring flexibility and adaptability for different sterilization needs.
Equipped with a microprocessor control and an easy-to-read LCD display, these autoclaves provide a user-friendly interface for precise control and monitoring. The devices offer four sterilization cycles, including Liquid, Instrument, Textile, and User-defined options, powered by a robust stainless steel 304 steam generator. The chamber, made entirely of stainless steel 304, ensures durability and reliability, with models providing chamber sizes ranging from 35L to 100L to accommodate various operational requirements.
Each unit comes with two stainless steel baskets for loading and offers optional features such as a drying function and a printer for enhanced usability. Compatible with a voltage of 110-220V and frequencies of 50/60Hz, these autoclaves are versatile and efficient, aligning with both small and large-scale operational needs. Users also benefit from the devices’ ability to display temperature with an accuracy of 0.1℃ and maintain a heat average of ≤±1℃, crucial for consistent sterilization results.
| Specification | YR05665 | YR05666 | YR05667 | YR05668 |
|---|---|---|---|---|
| Max. Working Pressure | 0.23Mpa | |||
| Design Temperature | 136℃ | |||
| Working Pressure | 0.22Mpa | |||
| Working Temperature | 134℃ | |||
| Working Temperature Range | 105 – 134℃ | |||
| Sterilization Time | 0 – 99 min or 0-99 hour 59 min | |||
| Accuracy of Temperature Display | 0.1℃ | |||
| Heat Average | ≤±1℃ | |||
| Type | Vertical Steam Autoclave | |||
| Control | Microprocessor | |||
| Display | LCD display | |||
| Sterilization Program | 4 cycles (Liquid, Instrument, Textile, User-defined) | |||
| Steam Generator | Stainless steel 304 | |||
| Material | Fully stainless steel 304 | |||
| Loading | 2 pcs stainless steel baskets | |||
| Language | English | |||
| Voltage | 110-220V. 50/60Hz | |||
| Optional | Drying function, Printer | |||
| Chamber Size(mm) | 35L / Ø318×450 | 50L / Ø340×550 | 75L / Ø400×600 | 100L / Ø440×650 |
| Outer Size(mm) | 470×450×1020 | 520×490×1150 | 550×530×1180 | 580×560×1290 |
| Packing Size(mm) | 540×540×1140 | 580×580×1250 | 610×610×1280 | 640×640×1360 |
| G.W. / N.W. | 81/63 kg | 94/74 kg | 113/93 kg | 125/105 kg |
| Power | 2.5 KW | 2.5 KW | 4.5 KW | 4.5 KW |
Market Price
When considering the acquisition of a vertical steam autoclave, potential buyers should anticipate a price range starting from approximately $3,500 to $4,200 USD. This range is reflective of the sheer sophistication and advanced technology incorporated into our autoclave models YR05665 to YR05668. The pricing can vary based on additional options or features selected, such as the drying function and integrated printer. Investing in these units ensures reliable performance and long-term operational benefits, making them a cost-effective solution for laboratories or healthcare facilities seeking top-quality sterilization equipment.
Frequently Asked Questions
What type of maintenance is required for the autoclave?
Regular maintenance of the autoclave includes cleaning the chamber, checking gaskets for wear, and ensuring water quality to prevent mineral deposits. Routine inspections help keep the unit functioning optimally.
How long does the sterilization cycle take?
The sterilization cycle length can be set anywhere between 0 to 99 minutes or extended for more complex processes up to 99 hours and 59 minutes, providing flexibility to match specific sterilization needs.
What is the maximum chamber capacity?
Depending on the model, the chamber capacity can range from 35 liters to 100 liters, accommodating various load sizes and types of equipment.
Advantages and Disadvantages
Advantages: The primary advantages of these vertical steam autoclaves include their highly durable stainless steel construction, precise control with microprocessor technology, and versatile sterilization programs. They are designed for efficiency and reliability, offering adjustable cycles and temperature ranges to suit various sterilization needs. The wide chamber capacity options ensure compatibility with diverse applications.
Disadvantages: While the autoclave’s advanced features offer exceptional performance, the initial investment can be considerable for smaller facilities. Additionally, the sophisticated technology may necessitate professional training for optimal usage. Nevertheless, the benefits often outweigh the disadvantages through enhanced productivity and reliable sterilization outcomes.
Field Use of the Product
In laboratory and healthcare settings, the LCD Display Hand Wheel Vertical Steam Autoclave plays an essential role by ensuring sterile conditions crucial for patient safety and research integrity. Users can efficiently sterilize surgical instruments, laboratory glassware, textiles, and other essential materials. The autoclave’s wide temperature range and precision controls make it a versatile choice in demanding environments, supporting critical functions with unparalleled reliability.
Field professionals in medical and research settings appreciate the autoclave’s reliable performance and adaptable settings. The robust stainless steel design withstands daily use, offering ease of operation with its intuitive LCD interface and comprehensive control options. The seamless cycle transitions and user-defined programs further contribute to reduced operational downtime, enhancing productivity.
Recommendations
To maximize the longevity and performance of your vertical steam autoclave, it’s recommended to adhere to a stringent maintenance schedule, including periodic checks and cleanings. Carefully monitor the water quality used in the autoclave to minimize mineral buildup and ensure consistent sterilization results. Fully utilize the user-defined program features to create specific cycles tailored to your facility’s needs, optimizing sterilization efficiency.
It is also advisable to undergo training on the perangkat’s full capabilities, allowing staff to leverage its advanced features effectively. Regular updates and calibration checks will ensure the autoclave remains in optimal working condition, guaranteeing compliance with industry standards and delivering dependable results.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each equipment with a level of excellence. Our intuitive and agile online shopping channels are designed for your convenience, ensuring the most friendly prices. Do not hesitate any longer, we bring science to life, it is time to become part of our community. https://kalstein.net/en/product/lcd-display-hand-wheel-vertical-steam-autoclave-yr05665-yr05668/.