Product Description
The Illumination (Ray radiation) incubators of the YR series are groundbreaking devices meticulously crafted to ensure a precise environmental simulation for your valuable research and laboratory work. Notably, this series includes three models: YR05328, YR05329, and YR05330, providing a spectrum of features designed to cater to diverse laboratory needs.
Key specifications include a temperature range with illumination from 10 to 60°C and without illumination from 5 to 60°C. These incubators maintain a consistent humidity range from 50% to 90%, with a humidity fluctuation of ±5% RH, ensuring reliable conditions for a wide array of experiments. The YR series boasts temperature uniformity values of ±1°C for YR05328 and YR05329, and ±1.5°C for YR05330, demonstrating superior performance in maintaining controlled environments.
| Product Name | Illumination (Ray radiation) incubator YR series | ||
| Model | YR05328 | YR05329 | YR05330 |
| Temp range ℃ | With illumination 10~60℃,With no illumination 5~60℃ | ||
| Humidity range | 50%~90% humidity fluctuation±5%RH | ||
| Temperature uniformity values ℃ | ±1 | ±1.5 | |
| Illumination LX | 0~10000 | 0~15000 | 0~15000 |
| Illumination set range | Five level(20%、40%、60%、80%、100%) | ||
| Timing range | 0~99h | ||
| Power W | 900 | 1000 | 1200 |
| Voltage V | 220 | ||
| Accuracy ℃ | ±0.1 | ||
| Volume L | 150 | 250 | 350 |
| Inner size (mm)(H*W*D) | 800*500*380 | 1000*550*450 | 1000*580*600 |
| Overall dimension (mm) (H*W*D) |
1525*735*680 | 1775*785*750 | 1775*815*900 |
| Packing size (mm) (H×W×D) |
1680*810*760 | 1925*860*830 | 1925*890*980 |
| Net weight (KG) | 120 | 155 | 188 |
| Shipping weight (KG) | 128 | 165 | 198 |
Market Price
When considering an illumination incubator, understanding the market price is crucial for making informed decisions. While the actual cost of these high-quality units can vary, the Illumination Incubator YR series generally falls within a moderate pricing band. For these technically advanced devices, prices typically range from $4500 to $5300 USD, reflecting both the technological sophistication and the reliability of the incubators. This range ensures you receive cutting-edge features and superior build quality without compromising your budget.
Frequently Asked Questions
What are the power requirements for the YR series incubators?
The YR series incubators require a power supply of 220V, with power consumption varying between the models: 900W (YR05328), 1000W (YR05329), and 1200W (YR05330).
How does the illumination feature enhance the incubator’s functionality?
The illumination offers robust light simulation with an adjustable range from 0 to 15000 LX. The illumination’s five-level setting allows precise control, making it instrumental in experiments where light conditions are pivotal.
What is the typical lead time for shipment?
The standard lead time for shipment is approximately 4 to 6 weeks, contingent upon the product’s availability and destination logistics.
Advantages and Disadvantages
One of the most significant advantages of the YR series incubators is the ability to simulate precise environmental conditions, supporting both temperature and humidity control. The units’ high-precision sensor system ensures consistent accuracy at ±0.1°C, crucial for critical experiments. Another advantage is the sophisticated illumination control, which offers tailored light conditions for various research needs.
However, a potential disadvantage is the dependency on stable electrical conditions due to their specific power demands. Additionally, while the price reflects the superior quality, it may present a budget challenge for smaller laboratories or educational institutions.
Field Use of the Product
In practical scenarios, the YR series incubators are vital in laboratories conducting experiments requiring stable climatic conditions. They are routinely used in plant growth studies, microbial cultures, and any research necessitating controlled light and humidity environments. The versatility of the YR series allows it to serve various disciplines, from biotechnology to agriscience.
In agricultural research, the ability to manipulate light and simulate different climatic conditions enables scientists to experiment with crop growth under varied environmental stressors. Similarly, in microbiology, the control over environmental conditions ensures reproducibility of experiments, essential in research and quality assurance processes.
Recommendations
For optimal use, it is recommended to maintain the incubators in a stable room environment to prevent unnecessary strain on their systems. Regular calibration checks and maintenance are imperative to ensure longevity and performance consistency.
Additionally, considering a power backup plan is prudent to protect research data during unexpected power interruptions. By integrating these best practices, users can maximize the potential of their YR series incubators, safeguarding the integrity and success of their experimental work.
If you are seeking a blend of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the most customer-friendly prices. Don’t hesitate any longer, we bring science to life, it’s time to be part of our community. Explore more here.