Product Description
Our Biological Safety Cabinets, models YR05270-1 and YR05271-1, are designed to provide a contamination-free environment critical for scientific experiments and research. Certified under ISO14644.1 CLASS 5 standards, these cabinets ensure maximum protection with an inflow velocity of 0.53m/s and a downflow velocity of 0.35m/s with a precision of ±0.015m/s.
These models integrate a high-efficiency HEPA filter capable of trapping 99.995% of particulate matter. The noise level is maintained ≤65 dB for a quiet working environment, enabling researchers to focus without distractions. Built to withstand minor vibrational disturbances, these cabinets exhibit vibration tolerance ≤3μm along X, Y, and Z axes.
Temperature control is a hallmark of these cabinets, operating efficiently in environments ranging from 10-30℃ with relative humidity maintained under 70%. Light intensity in the working zone is maintained at ≥650 LX, ensuring optimal visibility during operations.
| Model | YR05270-1 | YR05271-1 |
|---|---|---|
| Clean Rating | ISO14644.1 CLASS 5(US209E,CLASS 100) | |
| Inflow Velocity | 0.53m/s | |
| Down Flow Velocity | 0.35m/s | |
| Down Flow Velocity Precision | ±0.015m/s | |
| Noise Level(dB) | ≤65 | |
| Vibration | ≤3μm(X, Y, Z direction) | |
| HEPA | Efficiency 99.995% | |
| Light Intensity(LX) | ≥650 | |
| Pressure Difference Range (Pa) | 0~500 | |
| Operate Environment | environment temp.10-30℃,relative humidity under 70%, no obvious vibration and dust | |
| External Dimensions (H*W*D) (mm) | 2120×1035×740 | 2120×1340×740 |
| Dimension of Working Zone (H*W*D) (mm) | 670×965×560 | 670×1260×560 |
| Power(W) | 300 | 350 |
| Net Weight (KG) | 175 | 210 |
| Gross Weight (KG) | 195 | 235 |
| Package Size (H*W*D) (mm) | 1710×1205×910 | 1710×1510×910 |
Market Price
Biological Safety Cabinets like the YR05270-1 and YR05271-1 models serve as a long-term investment for laboratories. The market price for these units typically ranges from $7500 to $8300 USD, depending on the specifications and additional features included. This price range reflects the advanced technology and robust construction that you can expect from high-quality safety cabinets.
FAQs
What is the primary purpose of a biological safety cabinet?
A biological safety cabinet is designed to provide both protection for personnel and a sterile environment for sensitive work, such as microbiological research or tissue culture.
How often should the HEPA filter be replaced?
The HEPA filters should be checked regularly but generally require replacement every 12-18 months, depending on usage and environmental conditions.
Is special training required to operate these safety cabinets?
Yes, users should undergo training to familiarize themselves with operational procedures and safety protocols to ensure optimal performance and safety.
Advantages and Disadvantages
Among the primary advantages of these biological safety cabinets is their ability to maintain a contaminant-free environment, safeguarded by a HEPA filter with nearly 100% efficiency. The quiet operational noise ensures an undisturbed workspace, and its vibration resistance prevents disturbances to sensitive equipment.
As for disadvantages, the need for rigorous maintenance, including regular filter changes and inspections, could be seen as a constraint. Additionally, these units require a significant upfront investment, which might not be feasible for smaller laboratories with limited budgets.
Use of the Product in the Field
Biological safety cabinets are indispensable in fields such as microbiology, pharmaceutical research, and biotechnology. They create a sterile environment necessary for experiments involving cell cultures or pathogens, protecting both samples and personnel.
Scientists rely on these cabinets for delicate operations like gene cloning and tissue engineering, where a sterile environment is critical to prevent contamination and ensure the success of experiments.
Recommendations
For best results, always ensure that the cabinet is placed in an area free from disruptions and obstructions. Regular maintenance, including filter and pre-filter replacements, is crucial to ensure the optimal functioning of the units.
User training sessions are recommended. These should focus on proper handling and operational protocols to maximize safety and efficiency. Lastly, consider periodic calibration and validation checks, which will help maintain the unit’s compliance with safety regulations.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive laboratory equipment catalog. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the friendliest prices. Do not hesitate any longer, we bring science to life, it is time to become part of our community. https://kalstein.net/en/product/biological-safety-cabinet-yr05270-1-yr05271-1/.