Product Description
The YR05728 Laminar Flow Clean Bench from Kalstein is engineered to produce a contamination-free environment through a consistent stream of laminar air flow. This bench is meticulously designed to meet the demands of laboratories requiring a pristine workspace for delicate tasks. The clean bench provides a cleanliness level of Class 100@≥0.5μM as per US Federal 209E standards, ensuring that even the most sensitive experiments are not compromised by particulates.
Key to its superior performance, the YR05728 achieves an average wind speed of 0.25 to 0.45 m/s while keeping noise at a minimum with levels ≤62dB(A). The bench’s design takes vibration into account too, maintaining a vibration half-peak of ≤5μM across x, y, and z directions, and an illuminance of ≥300Lx provides sufficient light for detailed work. Structured to maximize user safety and comfort, this model also supports the high-efficiency filter specification of 850×565×50, ensuring optimal air purification.
| Model | YR05728 |
| Cleanliness Level | Class 100@≥0.5μM (US Federal 209E) |
| Number of Colonies | ≤0.5pcs/dish·hour (Φ90mm culture plate) |
| Average Wind Speed | 0.25~0.45m/s |
| Noise | ≤62dB(A) |
| Vibration half peak | ≤5μM(x、y、z direction) |
| Illuminance | ≥300Lx |
| Power Supply | AC single phase 220V/50Hz |
| Maximum Power | 490W |
| Weight | 90kg |
| Work area size W1×D1×H1 |
880×510×580 1040×690×1600 |
| Dimensions | Single/Single |
| High efficiency filter specification and quantity | 850×565×50 |
Market Price
In the competitive market of laboratory equipment, the YR05728 Laminar Flow Clean Bench typically finds its price range from approximately $1,500 to $2,300 USD. This range is reflective of the product’s high-caliber engineering and functionality, distinguishing it as a cost-effective choice for facilities that prioritize environmental precision and operator safety.
This model’s supreme filtration capacity and noise control justify the investment, showcasing a balance between innovation and value. Prospective buyers are encouraged to explore the possibilities of integrating the YR05728 into their labs by requesting a quotation via Kalstein Plus.
Frequently Asked Questions
What applications are suitable for the YR05728 Laminar Flow Clean Bench?
The YR05728 is ideal for tasks that require a sterile environment, such as microbiological testing, pharmaceutical preparations, and electronic component assembly.
Is it difficult to install and operate the clean bench?
The YR05728 is designed for user-friendliness, with clear instructions for installation and operation. It’s recommended to consult with professionals for installation to ensure optimal performance.
How often should the filters be replaced?
The frequency of filter replacement depends on the usage level and environment, but routine checks and maintenance are advised to ensure the best performance.
Advantages and Disadvantages
Advantages:
The YR05728 offers unmatched cleanliness standards, maintaining a controlled environment essential for precise research work. Its efficient design minimizes noise pollution, which is crucial for maintaining focus and precision in meticulous laboratory environments.
Additionally, the construction supports energy efficiency through its 490W power consumption, therefore, optimizing operational costs. The intelligent design of its workspace not only offers functionality but also reduces user fatigue by incorporating appropriate lighting and ergonomic considerations.
Disadvantages:
While the YR05728 excels in performance, its advanced technology requires a corresponding level of expertise in maintenance. Users should ensure proper training is provided to maximize the unit’s potential and longevity.
Product Use in the Field
In practical application, the YR05728 Laminar Flow Clean Bench is pivotal for creating environments where contamination control is paramount. It is frequently utilized in settings such as laboratories and manufacturing units dealing with sterile processing. The consistent air flow and cleanliness rating of this bench make it suitable for tasks where even minor contamination can result in significant setbacks.
Operators will appreciate the comfortable working conditions it provides, allowing for prolonged periods of productive work without discomfort. The efficiency of this bench streamlines workflows and enables critical tasks to be performed with precision and reliability.
Recommendations
To ensure the longevity and maximum performance of the YR05728 Laminar Flow Clean Bench, regular maintenance practices should be observed. Users should establish a periodic schedule for cleaning and check-ups to gauge filter efficacy and structural integrity. Proper operation training is essential to understand nuance control settings for wind speed and noise reduction.
Furthermore, ensuring the clean room’s surrounding air quality and room temperature is maintained can enhance the bench’s operational efficiency. Investing in this regular upkeep is crucial for safeguarding the bench’s capability to provide contaminant-free environments consistently.
If you are seeking a blend of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece with a level of excellence. Our intuitive and agile online shopping channels are designed for your convenience, ensuring the most friendly prices. Don’t hesitate any longer, we bring science to life, it’s time to be part of our community. https://kalstein.net/en/product/laminar-air-flow-clean-bench-yr05728/.