Advanced Features of the Benchtop Spectrophotometer YR05476

Product Description

The Benchtop Spectrophotometer YR05476 stands at the forefront of precise color analysis and transmission, designed to cater to a wide range of industries such as paints, inks, textiles, garments, printing, and dyeing. This versatile laboratory instrument boasts a sophisticated optical geometry with both reflective and transmissive capabilities, providing diffused illumination with an 8-degree viewing angle. Available in standardized color spaces including CIE LAB, XYZ, and HunterLab, it ensures accurate color matching and quality control.

Equipped with a concave grating spectrophotometric mode, the YR05476 uses a 256 Image Element Double Array CMOS Image Sensor to capture and process spectral data with remarkable accuracy. The integrating sphere, measuring Φ154mm, is accompanied by a broad wavelength range of 360 nm to 780 nm, complemented by various cut-off light sources. This device is built to conform to international standards, offering measurements compliant with CIE No.15, and ASTM E1164 among others.

Furthermore, the YR05476 supports various measuring apertures and allows users to present reflectance and transmittance with SCI/SCE specular components. The user interface features a 7-inch TFT color LCD with capacitive touch screen for intuitive operation and visual representation of spectrograms, chromaticity values, and color differences. Its data storage capabilities are robust, and connectivity options include USB, Bluetooth, and a print serial port, ensuring seamless integration into modern laboratory workflows.

Model YR05476
Optical Geometry Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing)SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source; Haze(ASTM D1003), Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7
Application It is used for accurate analysis and transmission of laboratory color. Apply in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control.
Integrating Sphere Size Φ154mm
Light Source 360 nm to 780 nm, Combined LED Light, 400nm cut-off light source,420nmCut-off light source
Spectrophotometric Mode Concave Grating
Sensor 256 Image Element Double Array CMOS Image Sensor
Wavelength Range 360-780nm
Wavelength Interval 10nm
Semiband Width 10nm
Measured Reflectance Range 0-200%
Measuring Aperture Reflective : Φ30mm/Φ25.4mm, Φ18mm/Φ15mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm;
Transmissive : Φ30mm/Φ25mm;
Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position
Specular Component Reflectance: SCI&SCE / Transmittance: SCI&SCE
Color Space CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99
Color Difference Formula ΔE * ab ,ΔE * uv ,ΔE * 94 ,ΔE * cmc(2:1) ,ΔE * cmc(1:1) ,ΔE * 00 , DINΔE 99 ,ΔE (Hunter),
Other Colorimetric Index WI (ASTM E313, CIE/ISO, AATCC, Hunter),
YI (ASTM D1925, ASTM 313),
MI (Metamerism Index),
Staining Fastness, Color Fastness, Color Strength, Opacity,
8° Glossiness,Gardner Index, Pt-Co Index, 555 Index, Haze(ASTM D1003)
Observer Angle 2°/10°
Illuminant D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12
Displayed Data Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset
Measuring Time About 2.4s (Measure SCI & SCE about 5s)
Repeatability Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.04% (400 nm to 700 nm: within 0.04%)
Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.01 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%)
Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)
Inter-instrument Error Φ25.4mm/SCI, Within ΔE*ab 0.12
(Average for 12 BCRA Series II color tiles)
Dimension L*W*H=370x300x200mm
Weight Approx. 9.6kg
Power AC 24V, 3A Power adapter power supply
Illuminant Life Span 5 years, more than 3 million times measurements
Display 7-inch TFT color LCD, Capacitive Touch Screen
Data Port USB & Bluetooth & Print serial port
Data Storage Standard 5000 Pcs, Sample 40000 Pcs
Language Simplified Chinese, Traditional Chinese, English, (Optional Customized German, French and Spanish)
Operating Environment 0~40℃, 0~85%RH (no condensing), Altitude < 2000m
Storage Environment -20~50℃, 0~85%RH (no condensing)
Standard Accessory Power Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 15 caliber, 8 caliber, 4 caliber,Transmissive Test Component
Optional Accessory Micro-printer, Micro Aperture(4mm) transmission test clamp component, Instrument inversion components
Notes: The specifications are subject to change without notice.

Market Price

The Benchtop Spectrophotometer YR05476 is positioned in the market as a premium instrument due to its highly advanced features and broad applicability. Typically, the market price for this model ranges between $14,000 and $15,000. This range reflects the quality and performance features that the YR05476 delivers, making it a valuable investment for any laboratory focused on precision in color measurement and quality control. When exploring the right spectrophotometer to enhance your laboratory capabilities, consider requesting a customized quote via Kalstein Plus to explore exclusive deals and packages tailored to your needs.

Frequently Asked Questions

What industries can benefit from using the YR05476 spectrophotometer?

The YR05476 spectrophotometer is ideal for industries such as paints, inks, textiles, garments, printing, and dyeing. It assists in ensuring accurate color transmission and quality control, critical for maintaining consistency across various applications.

How does this spectrophotometer ensure precision and accuracy?

With its concave grating spectrophotometric mode and 256 Image Element Double Array CMOS Image Sensor, the YR05476 accurately captures spectral data. Additionally, the wide range of standard color spaces and compliance with international color measurement standards ensure reliable color analysis.

What are the power requirements for the YR05476?

The spectrophotometer operates with an AC 24V, 3A power adapter, suitable for most laboratory settings.

Advantages and Disadvantages

The Benchtop Spectrophotometer YR05476 offers several distinct advantages. Its precision in color measurement, versatility in application, and integration with modern technology make it a superior choice for laboratories demanding high accuracy and reliability. The large touch screen and extensive data storage capabilities enhance user experience and efficiency in operation.

However, one potential disadvantage could be its price point, situated at the higher end of the market. Additionally, users may require advanced training to fully leverage the spectrophotometer’s capabilities, potentially increasing the initial set-up time and cost.

Field Usage

In real-world applications, the YR05476 spectrophotometer is pivotal in standardizing colors across various manufacturing processes. In the textile industry, for instance, it ensures consistent dyeing results, critical for maintaining brand standards and meeting consumer expectations. Similarly, in the printing industry, it aids in aligning printed colors with digital designs, thereby reducing material waste and improving production efficiency.

Furthermore, quality control laboratories use this instrument to monitor product specifications, ensuring that colors meet predefined standards throughout production cycles, thereby enhancing final product appeal and functional performance.

Recommendations

To maximize the benefits of the YR05476, it is essential to conduct regular maintenance checks and calibrations. Users are advised to conform to the recommended operating environment and storage conditions to extend the instrument’s lifespan. Engaging in hands-on training sessions may also empower operators to utilize the spectrophotometer’s full range of functions, elevating productivity and ensuring precise color measurements.

If you’re looking for a blend of innovation and quality, you’ve come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each device with excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the most friendly prices. Don’t hesitate any longer, we bring science to life, it’s time to become part of our community. https://kalstein.net/en/product/benchtop-spectrophotometer-yr05476/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]