Product Description
The Benchtop Spectrophotometer YR05476 stands at the forefront of technological innovation, designed to deliver precise color analysis and transmission in various laboratory settings. This state-of-the-art spectrophotometer supports a wide array of industries, including paints, inks, textiles, and more. Its optical geometry encompasses reflectance with diffused illumination at an 8-degree viewing angle either including or excluding the specular component (SCI/SCE), and it handles wavelengths ranging from 360 nm to 780 nm through its combined LED light source.
Furthermore, it boasts a commendable integrating sphere size of Φ154mm and utilizes a concave grating spectrophotometric mode for optimal performance. The YR05476’s sensor technology, a 256 Image Element Double Array CMOS Image Sensor, ensures accuracy with a wavelength interval and semiband width of 10 nm. Its capabilities extend to measuring a reflectance range of 0-200%, accommodating various measuring aperture sizes for both reflective and transmissive samples.
| Model | YR05476 |
| Optical Geometry | Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing)SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source; Haze(ASTM D1003), Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7 |
| Application | It is used for accurate analysis and transmission of laboratory color. Apply in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control. |
| Integrating Sphere Size | Φ154mm |
| Light Source | 360 nm to 780 nm, Combined LED Light, 400nm cut-off light source,420nmCut-off light source |
| Spectrophotometric Mode | Concave Grating |
| Sensor | 256 Image Element Double Array CMOS Image Sensor |
| Wavelength Range | 360-780nm |
| Wavelength Interval | 10nm |
| Semiband Width | 10nm |
| Measured Reflectance Range | 0-200% |
| Measuring Aperture | Reflective : Φ30mm/Φ25.4mm, Φ18mm/Φ15mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm; |
| Transmissive : Φ30mm/Φ25mm; | |
| Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position | |
| Specular Component | Reflectance: SCI&SCE / Transmittance: SCI&SCE |
| Color Space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99 |
| Color Difference Formula | ΔE * ab ,ΔE * uv ,ΔE * 94 ,ΔE * cmc(2:1) ,ΔE * cmc(1:1) ,ΔE * 00 , DINΔE 99 ,ΔE (Hunter), |
| Other Colorimetric Index | WI (ASTM E313, CIE/ISO, AATCC, Hunter), |
| YI (ASTM D1925, ASTM 313), | |
| MI (Metamerism Index), | |
| Staining Fastness, Color Fastness, Color Strength, Opacity, | |
| 8° Glossiness,Gardner Index, Pt-Co Index, 555 Index, Haze(ASTM D1003) | |
| Observer Angle | 2°/10° |
| Illuminant | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12 |
| Displayed Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset |
| Measuring Time | About 2.4s (Measure SCI & SCE about 5s) |
| Repeatability | Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.04% (400 nm to 700 nm: within 0.04%) |
| Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.01 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%) | |
| Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) | |
| Inter-instrument Error | Φ25.4mm/SCI, Within ΔE*ab 0.12 |
| (Average for 12 BCRA Series II color tiles) | |
| Dimension | L*W*H=370x300x200mm |
| Weight | Approx. 9.6kg |
| Power | AC 24V, 3A Power adapter power supply |
| Illuminant Life Span | 5 years, more than 3 million times measurements |
| Display | 7-inch TFT color LCD, Capacitive Touch Screen |
| Data Port | USB & Bluetooth & Print serial port |
| Data Storage | Standard 5000 Pcs, Sample 40000 Pcs |
| Language | Simplified Chinese, Traditional Chinese, English, (Optional Customized German, French and Spanish) |
| Operating Environment | 0~40℃, 0~85%RH (no condensing), Altitude < 2000m |
| Storage Environment | -20~50℃, 0~85%RH (no condensing) |
| Standard Accessory | Power Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 15 caliber, 8 caliber, 4 caliber,Transmissive Test Component |
| Optional Accessory | Micro-printer, Micro Aperture(4mm) transmission test clamp component, Instrument inversion components |
| Notes: | The specifications are subject to change without notice. |
Market Price
When considering the acquisition of a high-quality benchtop spectrophotometer, it is essential to evaluate the market dynamics that influence its price. Typically, spectrophotometers of this caliber range from approximately $14,200 to $15,000 USD. This range reflects the product’s sophisticated features and the specialized technology integrated into its design. Prospective buyers should consider both short-term investment costs and long-term benefits derived from enhanced efficiency and precision in color measurement brought by the YR05476.
To navigate your purchasing decision with clarity, Kalstein offers a robust platform for quoting and negotiating prices that suit your specific needs. While this spectrophotometer promises excellent performance and innovation, it remains competitively priced within its market segment. By using Kalstein Plus, customers can benefit from automatic quoting systems, ensuring transparency and efficiency. Contact Kalstein now to discover the most favorable financial options tailored for you!
Frequently Asked Questions
What industries can benefit from using the Benchtop Spectrophotometer YR05476?
This spectrophotometer is ideal for industries that require precise color transfer and quality control, such as paints, inks, textiles, garments, printing, and dyeing. Its versatility also makes it applicable in quality assurance laboratories and research institutions.
What is the data storage capacity of this device?
The YR05476 provides substantial storage capabilities, with the ability to store up to 5000 standard test records and 40,000 sample test records, ensuring comprehensive data management for extensive testing needs.
Advantages and Disadvantages
When considering the purchase of the Benchtop Spectrophotometer YR05476, it is crucial to weigh both its benefits and potential drawbacks. One of its major advantages lies in its high precision and broad wavelength range, providing reliable results for a spectrum of applications. Additionally, its user-friendly interface, enhanced by a 7-inch TFT color LCD capacitive touch screen, simplifies data operation significantly. Its robust design and construction ensure durability and consistent performance over time, further solidifying its value proposition.
On the downside, the device’s initial investment cost might be a consideration for smaller enterprises. Furthermore, although versatile, operators may require some training to fully utilize its advanced features effectively. Nevertheless, the high-quality outcomes and extensive functionalities offered by the YR05476 often justify these initial costs and learning curves, providing substantial long-term returns.
Field Use of the Product
The Benchtop Spectrophotometer YR05476 is prominently used in fields where exact color accuracy is paramount, such as textile manufacturing and paint formulation. In practical settings, this device assesses sample color and transmittance with exceptional precision. Its capability to include or exclude UV light and handle haze measurement in accordance with ASTM D1003 standards makes it invaluable for ensuring both product quality and compliance with industry standards.
The device’s robust construction and reliability ensure that it can perform consistently in varied environmental conditions as specified. Its adaptability in terms of cut-off light sources also facilitates its application in diverse contexts, enabling seamless integration into existing workflow processes that require stringent color analysis and quality control.
Recommendations
To maximize the performance and lifespan of the Benchtop Spectrophotometer YR05476, it is recommended that users conduct regular maintenance checks, focusing on the calibration and cleanliness of optical components. Familiarization with the device’s software and touchscreen operation will significantly enhance user interaction and data management. Utilizing the full range of illuminants and understanding the nuances of the different color spaces supported can leverage the device’s full potential, leading to improved analysis and decision-making in quality assurance processes.
For an optimal user experience, integrating this spectrophotometer within a comprehensive quality management system is suggested, allowing for more detailed reporting and better traceability in manufacturing processes. By contacting Kalstein, users can receive personalized support and guidance, ensuring the device is calibrated to deliver unmatched precision in their specific field applications.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with excellence. Our intuitive and agile online shopping channels are designed for your convenience, ensuring the most friendly prices. Do not hesitate any longer, we bring science to life; it’s time to be part of our community. https://kalstein.net/en/product/benchtop-spectrophotometer-yr05476/.