Advanced Insights into the LCD Display Pulsating Vacuum Autoclave

Product Description

The LCD Display Pulsating Vacuum Autoclave, models YR05673, YR05674, and YR05675, epitomizes cutting-edge sterilization technology. This range of autoclaves, classified as Class B, is engineered for optimal performance in medical and laboratory environments. With a maximum pressure of 0.23Mpa and a working pressure of 0.22Mpa, these autoclaves ensure rigorous sterilization standards are met. They operate within a maximum temperature of 136°C, with a working range from 105°C to 134°C, demonstrating precise temperature control with an accuracy of 0.1°C and heat distribution within ±1°C.

Equipped with an intuitive LCD display, this autoclave series integrates microprocessor control for enhanced operation reliability. The drying process is facilitated by a vacuum system, and both a built-in vacuum pump and steam generator contribute to efficient cycles. The user-friendly interface also includes pre-set, user-defined, and test sterilization programs, catering to various operational needs.

Model YR05673 YR05674 YR05675
Max. pressure 0.23Mpa
Working pressure 0.22Mpa
Max. temperature 136℃
Working temperature 134℃
Working temperature range 105 – 134℃
Vacuum rate -0.081Mpa
Sterilization time 0 – 99 min
Drying time 0 – 99 min
Accuracy of temperature 0.1℃
Heat average ≤± 1℃
Type Vertical Pulsating Vacuum Autoclave
Class Class B
Control Microprocessor
Door Hand wheel type quick open door
Display LCD display
Drying system Vacuum drying
Vacuum pump Built-in
Steam generator Built-in
Sterilization program Pre-set program + User-defined program + Test program
Water tank Yes
Printer Yes
Sterilization basket 2 PCS
Language English
Voltage 220-240V, 50/60Hz, single-phase
Chamber Size(mm) 50L / Ø340×550 80L / Ø420×600 100L / Ø440×650
Outer Size(mm) 660×460×1160 700×520×1250 700×520×1250
Packing Size(mm) 820×600×1400 820×620×1450 820×620×1450
G.W. / N.W. 120/100 kg 172/142 kg 176/146 kg

Market Price

In today’s market, the LCD Display Pulsating Vacuum Autoclave models range approximately between $7800 and $8600 USD, depending on the autoclave size and specific features required by the user. While prices can fluctuate based on various factors, this range provides a reasonable estimate for potential buyers considering this high-technology device. It’s always a strategic choice to request a detailed quotation to explore all the available options and current offers.

Frequently Asked Questions

What is the maximum load capacity for each model?

The YR05673 accommodates up to 50 liters, YR05674 supports 80 liters, and the YR05675 handles 100 liters.

Can the autoclave run custom sterilization programs?

Yes, it features user-defined sterilization programs alongside pre-set and test programs for maximum flexibility.

Is it compatible with all voltage standards?

The autoclave operates with a voltage requirement of 220-240V, 50/60Hz, single-phase, suitable for most standard installations.

Advantages and Disadvantages

Advantages: The autoclave’s advanced LCD display and microprocessor controls ensure precision and ease of use. Its built-in steam generator and vacuum pump enhance efficiency, streamlining the sterilization process. The capability to customize sterilization programs offers versatility for different applications.

Disadvantages: The advanced features might come with a steeper learning curve for those unfamiliar with such technology, and initial setup may require professional calibration to ensure optimal performance.

Product Usage in the Field

In practical scenarios, these autoclaves are invaluable in sterilizing surgical instruments, laboratory tools, and other clinical equipment, ensuring hygiene and safety standards are rigorously upheld. Due to their robust design and comprehensive functionality, they are prominently used in hospitals, research facilities, and academic laboratories worldwide.

The hand wheel type quick-open door facilitates rapid loading and unloading, significantly reducing downtime between cycles. This is particularly beneficial in high-demand environments requiring swift turnaround times.

Recommendations

To best maintain the LCD Display Pulsating Vacuum Autoclave, regular calibration and cleaning should be scheduled. Users should consult professional technicians for in-depth maintenance tasks to prolong the equipment’s lifespan and reliability. Keeping unit update logs can aid in assessing performance over time and facilitate timely interventions when necessary.

If you are seeking a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each equipment with a level of excellence. Our intuitive and agile online shopping channels are designed for your convenience, ensuring the most friendly prices. Don’t wait any longer, we bring science to life, it’s time to be part of our community. https://kalstein.net/en/product/lcd-display-pulsating-vacuum-autoclave-with-printer-yr05673-yr05675/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]